Instructions – Parts List GRACO INC.ąP .O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 2002, Graco Inc. is registered to I.S. EN ISO 9001 10:1 Fire–Ball r 425 Pump Low–pressure, medium volume pump used to transfer grease. 1800 psi (12.4 MPa, 124 bar) Maximum Working Pressure 180 psi (1.
2 309407 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 7 . . . . . . . . . . . . . . . . . .
3 309407 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being dispensed to. Refer to Grounding on page 5.
4 309407 W ARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury . D This equipment is for professional use only . D Read all instruction manuals, tags, and labels before operating the equipment.
5 309407 Installation NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. NOTE: Always use Genuine Graco Parts and Accessories, available from your Graco distributor . Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below .
6 309407 Installation Mount the pump to suit the type of installation planned. V ery heavy lubricants may require an inductor plate. See page 16 for the mounting hole layout and dimensions Install the air line accessories in the approximate order shown in the T ypical Installation.
7 309407 Operation W ARNING D This pump is designed to be used ONL Y in pumping non-corrosive and non-abrasive lubri- cants and greases. Any other use of this pump can cause unsafe operating conditions and result in component rupture, fire, or explosion, which can can cause serious bodily injury , including injection.
8 309407 T roubleshooting W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. Before servicing this equipment always make sure to Relieve the Pressure .
9 309407 Notes.
10 309407 Service TI2148A Fig. 3 12 11 6 25 15 2 31 3 14 4 30 16 5 7 8 9 10.
11 309407 Service Displacement Pump Repair W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. Before you start: D T o reduce down time, be sure you have all necessary repair parts available.
12 309407 Service 12. Slide priming plate (9) (beveled edge up) onto priming rod (8). Screw nut (10) onto priming rod and tighten. 13. Reconnect the pump’s ground wire to a true earth ground. Check V alve Adjustment This pump has an adjustable piston ball check.
13 309407 Notes.
14 309407 Parts TI2147A 1 13 12 3 4 14 15 35* 34* 36* 33* 20 36* 34* 35* 16 8 2 31 5 30 6 11 7 9 10 Packing, vee* Spacer*.
15 309407 Parts Model 965124, Series B stubby length Model 965129, Series B 400 lb. (180 Kg) drum length Ref No. Part N o. Description Qty . 1 { AIR MOT OR 1 2 183010 CYLINDER, pump, displacement (mod.
16 309407 Dimensions Priming Piston 6.5 in. (165 mm) Diameter 1” npt(f) Fluid Outlet 28.5 in. 13.9 in. (724 mm) (353 mm) 14 .6 in. (371 mm) 1/2 npt(f) Air Inlet TI2146A Model 965124 Model 965129 37.3 in. (947.4 mm) Model 965124 Model 965129 50.8 in.
17 309407 T echnical Data Fluid pressure ratio 10:1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air pressure operating range 40–180 psi (0.
18 309407 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Graco 965124 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Graco 965124 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Graco 965124, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Graco 965124 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Graco 965124, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Graco 965124.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Graco 965124. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Graco 965124 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.