Instr uctions/P ar ts Flat Line Spra y Systems Kits Heated or non-heated fluid ci rculation kits f or Merkur ® , Merkur ® Bello ws, and NXT ® Dura-Flo ™ Pumps. For pr ofessional use only . Maximum Fluid W orking Pressure: see T echnical Data on page 19.
2 3A1203B Contents 24F592 Merkur Non-Heated Ci r culation Kit . . . . . . 4 24F592 Kit Par ts . . . . . . . . . . . . . . . . . . . . . . . . . 4 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Installation . . . . . . . . . .
3A1203B 3.
24F592 Merkur Non-Heated Circulation Kit 4 3A1203B 24F592 Merkur Non-Heated Cir culation Kit 24F592 Kit P ar ts Mounting Mount the pump as explai ned in your separ ate pump manual . Installation NO TE: Apply pipe sealan t (19) to all non- swiv eling threads.
24F592 Merkur Non-Heated Ci rculation Kit 3A1203B 5 F IG . 1. 24F592 Merkur Non-He ated Circulat ion Kit TI16205a 13 16 20 14 17 15 9 8 5 6 22 Apply pipe sealant (19) to all non-swiv eling threads. Use bushing (12) only on pumps with 3/4 npt fluid inlet.
24F595 Merkur Bellows Non-Heated Circulation Kit 6 3A1203B 24F595 Merkur Bello ws Non-Heated Cir culation Kit 24F595 Kit P ar ts Mounting Mount the pump as explai ned in your separ ate pump manual . Installation NO TE: Apply pipe sealan t (19) to all non- swiv eling threads.
24F595 Merku r Bellows Non-Heated Circulation Kit 3A1203B 7 F IG . 2. 24F595 Merkur Bel lows Non-Heated Circulation Kit TI16208a 13 16 20 14 18 15 9 6 5 8 22 12 17 Apply pipe sealant (19) to all non-swiv eling threads. Use bushing (12) only on pumps with 3/4 npt fluid inlet.
24F595 Merkur Bellows Non-Heated Circulation Kit 8 3A1203B.
24F590 (120V) and 24F591 (240V) Me rkur Heated Circulation Kit 3A1203B 9 24F590 (120V) and 24F591 (240V) Merkur Heated Cir culation Kit 24F590 and 24F591 Kit P ar ts Mounting NO TE: See your separate pump an d heater manuals .
24F590 (120V) and 24F591 (240V) Merkur Heated Circulation Kit 10 3A1203B Installation NO TE: See your separate heater manual, supplied, f or heater installatio n and electr ical requirements. NO TE: Apply pipe sealan t (19) to all non- swiv eling threads.
24F590 (120V) and 24F591 (240V) Me rkur Heated Circulation Kit 3A1203B 11 F IG . 3. 24F590 and 24F59 1 Merkur Heated Circ ulation Kit TI16204a 13 16 20 14 17 15 9 8 5 6 22 1 2 21 4 2 10 7 18 12 25 3 Apply pipe sealant (19) to all non-swiv eling threads.
24F590 (120V) and 24F591 (240V) Merkur Heated Circulation Kit 12 3A1203B.
24F593 (120V) and 24F594 (24 0V) Merk ur Bellows Heated Circulation Kit 3A1203B 13 24F593 (120V) and 24F594 (240V) Merkur Bello ws Heated Cir culation Kit 24F593 and 24F594 Kit P ar ts Mounting NO TE: See your separate pump an d heater manuals .
24F593 (120V) and 24F594 (240V) Merkur Bellows Heated Circul ation Kit 14 3A1203B Installation NO TE: See your separate heater manual, supplied, f or heater installatio n and electr ical requirements. NO TE: Apply pipe sealan t (19) to all non- swiv eling threads.
24F593 (120V) and 24F594 (24 0V) Merk ur Bellows Heated Circulation Kit 3A1203B 15 F IG . 4. 24F593 and 24F59 4 Merkur Bellows Heated Ci rculation Kit TI16207a 13 16 20 14 17 15 9 8 5 6 22 25 1 21 4 2 10 18 25 3 Apply pipe sealant (19) to all non-swiv eling threads.
G25NXT and G45NXT Dura-Flo Pump 16 3A1203B G25NXT and G45NXT Dura-Flo Pump G25NXT and G45NXT Kit P art s Mounting Mount the pump as explai ned in your separ ate pump manual, supplied. Installation NO TE: Apply pipe sealant to all non-s wiv eling threads .
Wall Bracket Mounting Hole Diagrams 3A1203B 17 W all Brac ket Mounting Hole Diagrams 9.0 in. (228.6 mm) Six 0.40 (10 mm) diameter mounti ng holes F our 7/16 in.
Kit Mounting Bracket Diagrams 18 3A1203B Kit Mounting Brac ket Diagrams Mount pum p , using e xisting s crews TI16476a TI16475a B rac k e t 24A590 , f or 24F590 an d 24F591 Merkur Heated Cir culation .
Technical Data 3A1203B 19 Te c h n i c a l D a t a Kit Maximum Fluid Working Pres sure . . . . . . . . . . . . . . NO TE: Pump pressure must no t exceed this pres sure.
All written and visual data con tained in th is document reflects the late st product information available at the time of pu blica tion. Graco reserves the right to make changes at any time without notice. Original instructions. T his manual contains English.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Graco 3A1203B c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Graco 3A1203B - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Graco 3A1203B, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Graco 3A1203B va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Graco 3A1203B, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Graco 3A1203B.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Graco 3A1203B. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Graco 3A1203B ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.