Manuel d'utilisation / d'entretien du produit 311593N du fabricant Graco
Aller à la page of 20
311593N EN Operation E-Flo ® 4-Ball Piston Pumps Durable, energy efficient piston pumps f or high v olume paint circul ation applications. For prof essional use only . See page 3 f or model inf or mation, including maximum w ork ing pressure . See page 5 f or approv als.
Related Manua ls 2 311593N Contents Related M anuals . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 E-Flo 4-Ball Piston P umps . . . . . . . . . . . . . . . . . 3 Maximum W orking Pressure and Pump Operationa l Limits .
Models 311593N 3 Models E-Flo 4-Ball Piston Pumps Chec k your pump’ s identification plate (ID) f or the 6-digit part number of y our pump . Use the f ollowing mat r ix to define the const r uction of y our pump , based on the six digits . F or example , Pump P ar t No .
Models 4 311593N.
Approvals 311593N 5 Appr o vals The E-Flo Pump meet s requirements of the f ollowing appr ova l agencies. Ref er to the individual components f or other specific ha zardous location listings .
Warnings 6 311593N Wa r n i n g s The f ollowing wa r nings are f or the setup , use, groundin g, maintenance, and repair of this equ ipment. The e xclama- tion point symbol ale r ts you to a general w ar ning and the hazard symbo ls refer to pr ocedure-specific risks.
Warnings 311593N 7 ELECTRIC SHOCK HAZARD Improper groun ding, setup, or usage of th e system can cause electr ic shock. • T ur n off and disconnect power at main s witch bef o re disconnecting an y cables and bef ore servicing equipment. • Connect only to g rounded po wer source .
Overview 8 311593N Overview An electr ic motor (B ) provides input to a 75:1 gear reducer (GR), which driv es two fluid pumps (FP). See F IG . 1. The s troke positions of th e two pumps are offset to achiev e cons istent flow from the pum p assembly .
Overview 311593N 9 Key: A E-Flo Electric Circula tion Pump B* Explosion-Proof Electric Moto r C* Local Control Box D* V ariable F requency Drive (VFD) E** System P owe r Disconnect Switch F* Electrica.
Overview 10 311593N.
Ground the System 311593N 11 Gr ound the System The equipment m ust be grounded. Grou nding reduces the risk of static and electric shock b y providing an escape wire f or the electrical current due to st atic build up or in the e v ent of a shor t circuit.
Controls and Indicators 12 311593N Contr ols and Indicator s V ariable Frequenc y Drive (VFD) Use a v ar iable frequency drive (VFD) accessory to pro- vide motor driv e control to t he pump . Graco supp lies accessory 240V and 480V VFDs that optimize pump performance.
Setup 311593N 13 Setup Fill gear reducer reser v oir with oil Open the fill cap (FC) and f ill the gear reducer oil reser- v oir with 2 quar ts (1.9 liters) of Graco 288414 Oil (tw elve 1 quar t bottles). Chec k the oil lev el in the sight glass (SG) on the gear reducer housing.
Operation 14 311593N Operation Pressure Relief Pr ocedure 1. Set ST ART/ST OP s witch (ST) to STOP . See F IG . 4. 2. Push in SECURE DISABLE (SD) s witch. 3. Open the bac k pressure regulat or and all fluid drain valv es in the system, having a waste conta iner ready to ca tch drainage.
Operation 311593N 15 F IG . 7: Motor Speed and Flo w Char t Flow Rate gpm (lpm) 30 (114) 25 (95) 20 (76) 15 (57) 10 (38) 5 (19) Pump Cycles per Min ute 0 4 8 12 16 20 24 10 (300) 20 (600) 30 (900) 40 (1200) 50 (1500) 60 (1800) Motor Speed in Hz (rpm) 0 A B C Equations f or each line: 2000 cc Flow (gpm) = 1.
Maintenance 16 311593N Maintenance Preventive Maintenance Schedule Estab lish a prev entiv e maintenance schedule based on the equipmen t’ s repair histor y . Chec k Gear Reducer Oil Level Every day , check the oil le vel in the sight glass (SG) on the gear r educer , with th e motor r unning.
Maintenance 311593N 17 Flushing • Flush bef ore changing colors , bef ore storing, and bef ore repairing equipment. • Flush at th e lowest pressure p ossible . Ch eck con- nectors for leaks and ti ghten as nece ssar y . • Flush with a fluid that is c ompatible with the fluid being dispense d and the equipment wett ed par ts.
Technica l Data 18 311593N T echnical Data Maximum Working Pressu re . . . . . . . . . . . . . . E-Flo 1500: 42 5 psi (2.93 MP a, 29.3 bar) E-Flo 2000: 460 psi (3 .22 MP a, 32.2 bar) E-Flo 3000: 330 psi (2.3 1 MP a, 23.1 bar) E-Flo 4000: 250 psi (1.7 5 MP a, 17.
Technical Data 311593N 19 Pressure and Flow Capability of E-Flo F amily with 50 Hz Motor (continuous production use) Fluid Pressure psi (MP a, bar) 350 (2.41, 24.1) 300 (2.10, 21.0) 250 (1.72, 17.2) 200 (1.4, 14.0) 150 (1.03, 10.3) 100 (0.70, 7.0) 50 (0.
All written and visual data contained in this document reflects the latest product information available at the time of publica tion. Graco reserves the right to make changes a t any time without notice. Original instructions. T his manual contains English.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Graco 311593N c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Graco 311593N - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Graco 311593N, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Graco 311593N va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Graco 311593N, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Graco 311593N.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Graco 311593N. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Graco 311593N ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.