Instr uctions T opper Units 306556S EN Grease dispense unit with pneumatic pump eleva tor f or easy drum replacement. For prof essional use onl y . Model 226013 50:1 Ratio Fire-B all ® Pump 5000 psi (34 .5 MP a , 345 bar) Maximum W orking Pres- sure 100 PSI (0.
2 306556S Contents W arnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 Pressure Relie f Procedure .
Warnings 306556S 3 Wa r n i n g s The f ollowing warnings are f or the setup , use, g rounding, maintenance, and repair of this equipment. Th e e xclama- tion point symbol ale r ts you to a gene ral w arning and the hazard symbols ref er to procedure-specific risks .
Warnings 4 306556S T O XIC FLU ID HAZARD Hazardous fluid or to xic fumes can cause ser ious injury or death if splashed in the e ye s or on the skin, inhaled, or s wallo wed. • Know the specific hazards of the fluid you are us ing. • Store hazardou s fluid in an appro ved containe r .
Installation 306556S 5 Installation Gr ounding • Pump : Use a ground wire and clamp as shown in Fig 1. • Air and fluid h oses: Use only electrically conductiv e hoses.
Installation 6 306556S T ypical Installation The T ypical Installation (sho wn in fig 2) is only a guide f or selecting and installing this system. It is not an actual system design. Con tact y our local Gr aco representativ e f o r assistance in de signing a syst em to suit your par t icu- lar needs .
Installation 306556S 7 Mounting the Pump Models 226013, 226018, 244637 1. Mount the pump sup por t brac ket (86 ). (F IG . 4) 2. Remove inductor plate nut (11 or 2 4), locking ring (8 or 23) and o-ring (9). (F IG . 5) 3. In order , slide inductor pl ate nut (11 or 2 4 ), loc king ring (8 or 23) and o-ring (9) on pum p riser tube.
Installation 8 306556S All Models Ref er to F IG . 7 for the f ollowing Steps . 4. Loosen the pump su ppor t clamps again and r aise the suppor t (64) un til it meets the pump base. 5. Secure the Presiden t or Fire-Ball p u mp to the pump suppor t mounting plat es from the underside with the screws (68).
Installation 306556S 9 8. Install a b leed-type master air v alve on the pump’ s air supply line. 9. Install a fluid shutoff v alve on the fluid supply line to shut off fluid to the pump. 10. Finish assemb ling the hoses and fittings as shown on P ar ts Drawing P age 16.
Operation 10 306556S Operation Installing a Drum Ref er to F IG . 9 for the f ollowing instru ctions. 1. Relie v e the pressure, se e Pressure Relief Proce- dure, page 5. 2. Close the ball v alve (65). The h andle will be a t a 90° angle to the valve body .
Operation 306556S 11 Remo ving a Drum 1. Relive pressure, see Pressure Relief Proce dure, page 5. 2. Press in and hold the air-as sist v alv e (47) until the inductor plate rises abov e the drum. Release the va lve . ( F IG . 9) 3. Open the snap-over v alve (27) a nd raise the elev a - tor to full height.
Maintenance 12 306556S Maintenance Ref er to F IG . 10 f or ref erence numbers . NO TE: T o av oid contaminating the fluid in the supply container , k eep the pump intak e and the induct or plate clean during the servicing operations. Place the par ts on clean paper or r ags.
Troubleshooting 306556S 13 T r oubleshooting Prob lem Cause Solution Low f low or air suck ed into pump or under indu ctor plate. 1. Open inductor plate v ent 2. Loose inductor plate slee ve lock- ing nut 3. Worn indu ctor seals 1. Close the inductor plate .
Parts 14 306556S Pa r t s Model 204490 Elev ator and Inductor Plate Asse mbl y Includes items 17, 25, 90, and 101 Model 226013 Pump, Elev ator , and Inducto r Plate Assembly Includes items 1, 25, 89, .
Parts 306556S 15 Ref No. 1: P ar t No. 204353 Inductor Plate Assembly: 400 lb Drum size Fits 50:1 Fire-Ball In-Line Pump; Includes items 2-16 Ref No. 17: P a rt No. 204405 Inductor Plate Assembly: 400 lb Drum size Fits Monarch and Presiden t In-Line Pumps Includes items 3 - 7, 10, 12 - 16, 18 - 20 Ref No.
Parts 16 306556S aa 0731 0729 0730 Ref. No. 27 Snap-Over V alve Assembly Includes items 28 to 40 Ref. No. 42 Restrictor V alve Assembly Includes items 43 to 46 Ref.
Parts 306556S 17 Ref No. 25: P ar t No. 204461 Wishbone Suppor t Assembl y Ref No. P a rt No. Description Qty . 27 202295 SNAP-O VER V AL VE ASSEMBL Y Includes items 28 - 40 28 100272 LOCKW ASHER, int.
Parts 18 306556S Ref No. 91: P ar t No. 204467 Fire-Ball Delivery Hose Kit Includes items 92 - 94, 96, and 115 Ref No. 97: P ar t No. 205102 President Delivery Hose Kit Includes items 94, 96, 98, 99, and 110 Dimensions Ref No. Part No. Description Qty .
Technical Data 306556S 19 Te c h n i c a l D a t a See the pump instruction manual f or T echnical Data including W etted P ar ts, P or t Sizes , and so on. . T opper Units US Metric Maximum fluid w or king pressure 50:1 Ratio Fire-Ball Pump 5000 psi 34.
All written and visual data con tained in th is document reflects the late st product information available at the time of pu blica tion. Graco reserves the right to make changes at any time without notice. For patent information, see www.graco.com/pate nts.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Graco 244637 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Graco 244637 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Graco 244637, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Graco 244637 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Graco 244637, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Graco 244637.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Graco 244637. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Graco 244637 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.