Manuel d'utilisation / d'entretien du produit 230993 du fabricant Graco
Aller à la page of 16
Instructions – Parts List GRACO INC.ąP .O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 1985, Graco Inc. is registered to I.S. EN ISO 9001 55 GALLON SUPPL Y PUMPS 3:1 President r , 4:1 President r , and 2:1 Monark r With drum cover and agitator Model 220575, Series B with 3:1 Ratio President Pump 500 psi (3.
2 307745 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setup Grounding 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Positioning the Unit 5 . . . . . . . . . . . . . .
307745 3 W ARNING MOVING P ARTS HAZARD D The air motor piston can pinch or amputate your fingers. D The rotating blades of the agitator can pinch or amputate your fingers or other body parts and can cause splashing in the eyes or on the skin.
4 307745 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 5.
307745 5 Setup NOTES: D Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. D Accessories are available from your Graco repre- sentative. If you supply your own accessories, be sure they are adequately sized and pressure-rated to meet the system’s requirements.
6 307745 Setup The installation shown in Fig. 2 is only a guide for selecting and installing system components and accessories. Contact your Graco representative for assistance in designing a system to suit your particular needs. Connecting the Unit and Accessories D Ground the unit as described in Grounding on page 5.
307745 7 Operation Pressure Relief Procedure W ARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally .
8 307745 Operation 8. Shut off the air to the pump, open the bleed–type master air valve, and open the drain valve (K). Leave the solvent in the system overnight or , if possible, all weekend. 9. Start the pump and circulate it again for 30 min- utes.
307745 9 Operation Shutdown and Care of the Pump W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. Never allow paint to dry in the pump and lines. T o shutdown the system 1.
10 307745 Parts Drawing c Fig. 3 1 or 5 2 3 6 (MONARK PUMP SHOWN) 10 9 8 11 Model 230993, Series B 2:1 Ratio Monark Carbon Steel 55 Gallon Drum System Includes items 2 to 6, and 1 1 Model 230992, Seri.
307745 1 1 Parts List Model 230992, Series B 4:1 Ratio President Carbon Steel 55 Gallon Drum System Includes items 1 to 4, and 6 to 12 Model 230993, Series B 2:1 Ratio Monark Carbon Steel 55 Gallon Drum System Includes items 2 to 6, and 1 1 Ref. No. Part No.
12 307745 Parts Drawing 7679A Model 220575, Series B 3:1 Ratio President Stainless Steel 55 Gallon Drum System Includes items 1–35 Ref No. 6 includes items 6a–6d. Ref No. 5 includes items 5a–5c. 1 2 5a 35 3 6a 6b,6c 6d 4 1 2 Remove and discard 1/2 x 3/8 npt nipple from outlet of air regulator (5a), and replace with 1/2 npt nipple (5c).
307745 13 Parts List Model 220575, Series B 3:1 Ratio President Stainless Steel 55 Gallon Drum System Ref Part No. No. Description Qty 1 220564 PUMP , President See 308793 for parts 1 2 237309 COVER, drum, 55 gal.
14 307745 Notes.
307745 15 T echnical Data Category Model 220575 Model 230992 Model 230993 Ratio 3:1 4:1 2:1 Maximum fluid working pressure 500 psi (3.5 MPa, 35 bar) 400 psi (2.8 MPa, 28 bar) 200 psi (1.4 MPa, 14 bar) Maximum air input pressure 166 psi (1.2 MPa, 1 1.6 bar) 100 psi (0.
16 307745 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Graco 230993 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Graco 230993 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Graco 230993, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Graco 230993 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Graco 230993, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Graco 230993.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Graco 230993. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Graco 230993 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.