Manuel d'utilisation / d'entretien du produit P422 du fabricant Giant
Aller à la page of 12
P400 Series - 22 and 25mm V ersions Contents: Installation Instructions: page 2 Pump Specifications (except P425): pages 3-5 Exploded View: page 6 Parts List/Kits: page 7 Pump Specifications (P425): page 8 Repair Instructions/Torque Specs.
2 INST ALLA TION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connections, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
3 NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
4 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position.
5 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position.
6 EXPLODED VIEW - P420/P420-0011/P420-0021/ P422/ P423 AND P425 PUMPS.
7 ITEM PART DESCRIPTION QTY. 1 08377 Crankcase 1 2 08378 Oil Fill Plug with Gasket 1 3 06479 Crankcase cover 1 3A 07186 Oil Sight Glass w/ Gasket 1 4 08380 O-Ring 1 5 07109 Oil Drain Plug 1 5A 07182 G.
8 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. NOTES: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position.
9 Repair Instructions P420/P420-0011/P420-0021/P422/P423 and P425 Note: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.
10 Contact Giant Industries for service school information. Phone: (419) 531-4600 11) After installation of high pressure seals (23), place seal adaptor (20) with weep seals & pressure ring installed, weep return ring (25) and high pressure weep return ring (24) over plungers.
11 PUMP SYSTEM MALFUNCTION MALFUNCTION CAUSE REMEDY The Pressure and/ Worn packing seals Replace packing seals or the Delivery Broken valve spring Replace spring Drops Belt slippage Tighten or Replace.
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-service car wash applications, the discharge manifolds will never fail, period.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Giant P422 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Giant P422 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Giant P422, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Giant P422 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Giant P422, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Giant P422.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Giant P422. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Giant P422 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.