Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual For Models: P217 P218 P219 P220 P221 P227 P230 Series P 200A -18mm versions Contents: Installation Instructions: page 2 P.
2 INSTALLATION INSTRUCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
P217A HORSEPOWE R REQUIREM ENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.3 0.2 0.3 0.4 0.4 500 0.5 0.4 0.5 0.7 0.9 1000 1.0 0.7 1.1 1.4 1.8 1450 1.5 1.0 1.5 2.1 2.6 1750 1.8 1.2 1.9 2.5 3.1 3000 2.9 2.0 3.0 4.0 5.0 3200 3.1 2.1 3.2 4.2 5.3 3450 3.
P218A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.5 0.3 0.5 0.7 0.8 500 1.0 0.7 1.0 1.3 1.7 1000 1.9 1.3 2.0 2.7 3.4 1450 2.
P219A HORSEPOWER REQUIREM ENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.6 0.4 0.6 0.8 1.0 500 1.2 0.8 1.2 1.7 2.1 1000 2.4 1.7 2.5 3.3 4.1 1450 3.
6 Specifications Model P220A NOTE: In order to drive the pump from the side opposite the present shaft extension, simply remove the valve casing from the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are down at the six o'clock position.
P221A HORSEPOWER REQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.3 0.2 0.3 0.5 0.6 500 0.7 0.5 0.7 0.9 1.2 1000 1.3 0.9 1.4 1.8 2.3 1450 1.9 1.3 2.0 2.7 3.3 1750 2.3 1.6 2.4 3.2 4.0 3000 3.7 2.5 3.8 5.0 6.3 3200 3.9 2.7 4.0 5.4 6.7 3450 4.
P227 HORSEPOWER R EQUIREMENTS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.3 0.2 0.3 0.4 0.5 500 0.6 0.4 0.6 0.8 1.0 1000 1.2 0.8 1.2 1.7 2.1 1450 1.7 1.2 1.8 2.4 3.0 1750 2.1 1.4 2.2 2.9 3.6 3000 3.3 2.3 3.4 4.6 5.7 3200 3.5 2.4 3.6 4.9 6.1 3450 3.
P230 HORSEPOWER REQUIREMEN TS RPM GPM 1000 PSI 1500 PSI 2000 PSI 2500 PSI* 250 0.2 0.1 0.2 0.2 0.3 500 0.3 0.2 0.3 0.4 0.5 1000 0.6 0.4 0.7 0.9 1.1 1450 0.9 0.6 0.9 1.3 1.6 1750 1.1 0.8 1.1 1.5 1.9 3000 1.8 1.2 1.8 2.5 3.1 3200 1.9 1.3 2.0 2.6 3.3 3450 2.
10 Exploded View P217/P218/P219/P220/P221/P227/P230 Pump s.
ITEM PART NO. DESCRIPTION QTY. 1 6A 08468 Plunger Base 3 16B 08455 Plunger Pipe 3 16C 08456 Tension Screw 3 1 6D 07676 Copper Gasket 3 17 08442 Wrist Pin 3 18 07770 O-Ring 3 19 08356-0010 Oil Seal 3 2.
12 Rep air Kit s P217/P218/P219/P220/P221/P227/P230 Pump s Plunger Packing Kit Part # 09164 Item # Part # Description Qty. 23 08477 V-Sleeve, weep 3 2 3A 08087 V-Sleeve, brown 3 24 07904 Pressure Ring 3 Valve Assembly Kit Part # 09116 Item # Part # Description Qty.
13 PUMP SYSTEM MALFUNCTION MALFUNCTION CAUSE REMEDY The Pressure and/ Worn packing seals Replace packing seals or the Delivery Broken valve spring Replace spring Drops Belt slippage Tighten or Replace.
REPAIR INSTRUCTIONS - P217/P218/P219/P220/P221/P227/P230 PUMPS 10 NOTE: Always take time to lubricate all metal and nonmetal parts with a light film of oil before reassembly. This step will ensure proper fit, at the same time protecting the pump nonmetal parts (i.
15 Reassembly sequence of the P217/P218/P219/P220/P221/P227/P230 pumps 1 ) If oil seals (19) were removed, replace with seal lip towards crankcase. Lubricate seals before replacing. 2 ) Replace seal case (20) with o-rings (21) over plungers. Generously lubricate o-rings and oil seal before reassembly.
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and self-serve car wash applications, the discharge manifolds will never fail, period.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Giant P230 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Giant P230 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Giant P230, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Giant P230 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Giant P230, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Giant P230.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Giant P230. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Giant P230 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.