Manuel d'utilisation / d'entretien du produit P200A-5100 du fabricant Giant
Aller à la page of 16
Contents: Installation Instructions: page 2 Pump Specifications: pages 3-9 Exploded View: page 1 0 Parts List / Kits: page 1 1 Torque Specifications: page 1 1 Repair Instructions: pages 12-13 Pump mou.
2 INST ALLA TION INSTR UCTIONS 4. Use of a dampener is necessary to minimize pulsation at drive elements, plumbing, connec- tions, and other system areas. The use of a dampener with Giant Industries, Inc. pumps is optional, although recommended by Giant Industries, Inc.
3 Specifications Model P217A-3100/5100 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. U.S. (Metric) 1750 RPM + Ratings .........................................
4 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. Specifications Model P218A-3100/5100 U.S. (Metric) V olume ....................................................
5 Specifications Model P219A-3100/5100 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. PUMP PULLEY MOTO R PULLEY RPM GPM 800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI 7.
6 Specifications Model P220A-3100/5100 Consult the factory for special requirements that must be met if the pump is to operate beyond one or more of the limits specified above. PUMP PULLEY MOTO R PULLEY RPM GPM 800 PSI 1200 PSI 1500 PSI 1700 PSI 2000 PSI 7.
7 NOTE: In order to drive the pump fr om the side opposite the pr esent shaft extension, simply remov e the valve casing fr om the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to rotate the seal case (item #20) as well, so that the weep holes are do wn a t the six o'c loc k position.
8 NOTE: In order to drive the pump fr om the side opposite the present shaft extension, simply remo ve the valve casing fr om the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to r otate the seal case (item #20) as well, so that the weep holes are do wn a t the six o'c loc k position.
9 NOTE: In order to drive the pump fr om the side opposite the present shaft extension, simply remov e the valve casing fr om the crankcase and rotate the pumps 180 degrees to the desired position. Be certain to r ota te the seal case (item #20) as well, so that the weep holes are do wn a t the six o'c loc k position.
10 Exploded V iew - P200A-3100/5100 Series.
11 ITEM PART NO. DESCRIPTION QTY. 1 08300 Crankcase 1 2 08301 Dipstick 1 3 08302 Crankcase Plug Cover 1 3A 07190-0100 D rain Plug & Gasket 1 4 08005 O-Ring 1 5 08185-0100 Oil Drain Plug with seal 1 6 07188-0100 Screw, 316 S.S. 4 6A 07223-0100 Spring Washer, 316 S.
12 REP AIR INSTRUCTION - P200A-3100/5100 SERIES 1. W ith a 22mm socket wrench, remove the (3) discharge valve plugs and (3) inlet valve plugs (32) Inspect the o-ring (33) for wear and replace if dam- aged. 2. Using a needle nose pliers, remove the inlet and discharge valve assemblies (27-30) and o-ring (31).
13 Disassembly sequence of the back end of the P200A-3100/5100 series pump. 1) Before you begin, drain the oil from the crankcase. 2) Remove the crankcase cover (3) and o-ring (4) from the crankcase (1). T o remove the crankshaft (13), remove the bearing cover (7) and sight glass (8).
14 Preventative Maintenance Check-List & Recommended Spar e Parts List Check Daily W eekly 50hrs Every Every Every 500 hrs 1500 hrs 3000 hrs Oil Level/Quality X Oil Leaks X W ater Leaks X Belts, P.
15 P200A-3100/5100 DIMENSIONS - INCHES (mm).
GIANT INDUSTRIES LIMITED WARRANTY Giant Industries, Inc. pumps and accessories are warranted by the manufacturer to be free from defects in workmanship and material as follows: 1. For portable pressure washers and car wash applications, the discharge manifolds will never fail, period.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Giant P200A-5100 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Giant P200A-5100 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Giant P200A-5100, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Giant P200A-5100 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Giant P200A-5100, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Giant P200A-5100.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Giant P200A-5100. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Giant P200A-5100 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.