Manuel d'utilisation / d'entretien du produit 005223-0 du fabricant Generac Power Systems
Aller à la page of 56
ST ANDBY GENERA T OR O WNER'S MANU AL This manual should remain with the unit. A ne w standar d of reliability Serial Number QT 3.9L 40kW Model: 005223-0 CENTURION CENTURION C E N T U R I O N ® N ot i nt ended f or us e i n c r i t i c al l i f e s uppor t appl i c at i ons.
Standby Generator Sets T able of Contents SECTION P AGE SAFETY RULES ................................................ 1-1 INTRODUCTION ..................................................... 1-3 Read this Manual Thoroughly ..............................
Study these SAFETY RULES carefully before install- ing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reli- ably only if it is properly installed, operated and maintained.
• Before performing any maintenance on the gen- erator , disconnect its battery cables to prevent accidental start -up. Disconnect the cable from the battery post indicated by a NEGA TIVE, NEG or (–) first. Reconnect that cable last. • Never use the generator or any of its parts as a step.
1-3 I NTRODUCTION Thank you for purchasing this model of the standby generator set product line. Every effort was expended to make sure that the information and instructions in this manual were both accurate and current at the time the manual was written.
I DENTIF ICA TION R E C OR D D A T A LA BE L Every generator set has a DA T A LABEL that contains important information pertinent to the generator . The data label, which can be found attached to the .
E QUIPM ENT DE SCRI PTION This equipment is a revolving field, alternating cur - rent generator set. It is powered by a gaseous fueled engine operating at 1800 rpm for 4-pole direct drive units, 3600 rpm for 2-pole direct drive units and 2300 - 3000 rpm for quiet drive gear units.
ENGI NE P RO TE CTIVE DEVICE S The standby generator may be required to operate for long periods of time without an operator on hand to monitor such engine conditions as coolant tempera- ture, oil pressure or rpm.
F U E L SYST E M FUE L RE QUIRE MEN T S The standby generator may be equipped with one of the following fuel systems: • Natural gas fuel system • Propane vapor (PV) fuel system The Manual Drawing .
SP E CIF ICA TIONS GEN ERA T OR T ype ............................................................................. Synchronous Rotor Insulation ................................................................... Class H Stator Insulation ............
COLD WEA THER KIT F or cold climates, optional cold weather kit (part number 0F6148) is recommended. The kit includes: • Battery W armer • 4” Junction Box with hardware • 6 qt. pack 5W -30 synthetic oil (engine) R E C ONF IGU RI NG TH E FU EL SY S TEM NOTE: All models are configured for natural gas or LP vapor from the factory .
GEN ERA T OR A C LEAD C ON NECTIONS See “V oltage Codes”. This generator may be rated at any one of three voltages, either single -phase or three -phase. The electrical wires in the unit ’s A C con- nection (lower) panel should be installed according to the number of leads and the voltage/phase required for the application.
I NS T ALLA TION Refer to the separate “Installation Guide QT Product Line” supplied with the unit. P REP AR A TION BEFOR E ST ART -UP The instructions in this section assume that the standby generator has been properly installed, ser - viced, tested, adjusted and otherwise prepared for use by a competent, qualified installation contractor .
S T ART -U P CH E CKLIS T Before working on the generator , ensure the fol- lowing: • The AUTO/OFF/MANU AL switch is in the OFF position. • The 120V AC supply to the battery charger is switched OFF . P REP AR A TION FOR ST ART -UP • Ensure that the 120V AC circuit breaker to the bat - tery charger is open.
GEN ERA T OR C ONTROL AN D OP ERA TION Refer to the appropriate control panel operator’s manual for this unit. OP ERA TI NG U N IT WITH MAN U AL TR ANSFER SWIT CH If the generator was installed in conjunction with a transfer switch capable of manual operation only , the following procedure applies.
MAI NTENANCE PER FOR M ED B Y AUTHOR IZED SERVICE F ACILITI ES Before working on the generator , ensure the fol- lowing: • The AUTO/OFF/MANU AL switch is in the OFF position. • The 15A fuse has been removed from the con- trol box. • The 120V AC supply to the battery charger is switched OFF .
ENGI NE COOLANT Check coolant level in coolant recovery bottle. See the “Specifications” section. • Add recommended coolant mixture as necessary . • Periodically remove radiator pressure cap to make sure the coolant recovery system is functioning properly .
7. Start engine and check for oil leaks. Figure 10.2 - Oil Filter Oil Filter CHANGI NG THE ENGI NE AI R CLEAN ER T o replace the engine air cleaner , (part number 0A4637), remove the air cleaner cover and replace the air filter making sure it is positioned properly before reattaching the cover .
BA TTER Y MAI NTENANCE The battery should be inspected per the “Service Schedule” section. The following procedure should be followed for inspection: 1. Inspect the battery posts and cables for tightness and corrosion. Tighten and clean as necessary .
SERVICE S CH EDULE 30 KW - 1 5 0 KW ST ANDBY GAS ENGIN E DRIVEN GEN ER A T OR SET S The following is a recommended maintenance schedule for standby gas engine driven generator sets from 30kW to 150 kW in size. The established intervals in the schedule are the maximum recommended when the unit is used in an average service application.
Maintenance Level 1 Level 2 Level 3 Level 4 Level5 T asks Recom- T ask Required T ask Required T ask T ask Required T ask mended Comp. to be done Comp.
Maintenance Level 1 Level 2 Level 3 Level 4 Level5 T asks Recom- T ask Required T ask Required T ask T ask Required T ask mended Comp. to be done Comp.
Maintenance Level 1 Level 2 Level 3 Level 4 Level5 T asks Recom- T ask Required T ask Required T ask T ask Required T ask mended Comp. to be done Comp.
TROU BLESHOO TI NG GU IDE P ROBLEM CAUSE C OR RECTION Engine won’t crank. 1. 15 amp fuse blown. 1. Replace fuse . 2. Loose or corroded or defectiv e 2. Tighten, clean or replace batter y cab les. batter y cab les as necessar y . 3. Defectiv e star ter contactor .
Standby Generator Sets Notes.
Standby Generator Sets Notes.
Standby Generator Sets Notes.
.
1 0F3137 1 PAN CB CO NN BOX 2 0F3 1 88 1 STAN D RH CO NT R OL 3 0F3 189 1 ST AND LH CONTR O L 4 023484N 1 BU SHING SNAP SB-2.5-31 5 *** 0F6366B 1 / 2 XFMR DUAL 120V/1 6 V (FOR 120/240 V & 277/480 .
.
1 0F343 8 1 RTR 390 30 AD1 CPL 0F344 0 1 RTR 390 40 AD2 C PL HI-EF 0F61 88 1 AS S Y RTR 39 0 30 KD 1 CP L 0F61 90 1 AS S Y RTR 39 0 40 KD 2 CP L 2 0F3 4 39 1 S TR 39 0 30 AD 1 CP L 0F34 41 1 S TR 39 0.
.
1 0F327 0 1 MTG BASE 3. 9L 40KW C2 2 0528 6 0 4 NUT FLANGE D HE X M12-1 .75 3 05225 1 4 DAM PENE R VIBR ATION 40 B LUE 4 052257 4 SPACER .49 X .62 X 1.87 PWDR/ZNC 5 05225 2 4 DAM PENE R VIBR ATION 6 05225 9 4 WAS HER FL AT M 12 7 0528 91 4 S CREW HH C M12- 1.
.
1 0F3408 1 TRA Y BAT TER Y 2 0F 3 4 11 1 STRAP BA TTERY RET AINMENT 3 0582 08 REF BATT 12VDC 24 F 62 5 4 0368 3 3 1 SCREW HH C 3/ 8- 1 6 X 1 G8 5 02223 7 1 WASHE R LOCK 3/8 6 0221 31 1 WASHE R FLAT 3/8-M1 0 ZINC 7 050331A 1 BATT POST COVER RED + 8 050331 1 BATT POST COVER BLK - 9 038805 H 1 CAB LE BA TT BL K #1 X 2 3.
.
1 0E5048A 1 FLEXPLATE HSB 3.9L CHRYSL ER (1800RPM) 0F3903A 1 FLEX PLATE 2 POLE 3.9L CHR Y (360 0R PM) 2 0F2982 1 ENG ADAPTER MACH 3.9L HSB NSPS 3 0E67 03 1 COVER FLYWH EEL ACCESS 4 0F3795 REF ENGIN E INSER T ED VAL VE 3.9L (3600 RPM) 0E8336 REF MAKE 3.
.
1 0F18 23A 1 E NCL HS B CONT ROL PANEL 2 0F30 78 1 CO VE R CO NTR O L P ANEL 3 0F26 06 1 HIN GE C ONTINUO US H-P NL 4 036261 6 RIVET POP .125 X .27 5 SS 5 0F26 27 A 1 COVER CONTR OL P ANEL SIDE 6 043181 4 SCREW PHM M3-0 .5 X 10MM 7 052777 7 WAS HER FL AT M 3 8 0F42 45A 1 AA SY PCB CO MM CTR LR 1 80 0 RPM 9 * 0F126 2 4 HOLDER FUSE WI CKMA NN 178 .
.
1 0F32 03 1 WELDME NT R AD SUPP ORT 3.9L C2 2 03 5685 4 CLAMP HO SE #2 8 1. 32-2. 25 3 0F260 8 1 RADIAT OR 598 X 568 X 49 C PL RH 4 0F4 413 1 HOSE UP PER R AD CP L C2 3.9L 5 0F4 4 14 1 HO SE LOWE R RAD CPL C2 3. 9L 6 0E7854 1 CLUTC H COOLING FAN 7 0F282 0 1 FAN 22 " DIA 10 BL AD E 8 05 1756 4 SCREW HHC M 10-1.
.
1 0F65 04 1 PIP E R/H S IDE MU FFLER 2 0F 3127 1 PIPE L/H SI D E 3.9L C PL 3 0F2808B 1 PIPE EXHAUST M UFFLER OUT 4 0F07 38 1 MUFF LER 7" X 9"-(2) 2" I N/2.5" OUT 5 0F29 62 1 MUFF LER STR AP 6 0F28 30 1 MUFF LER B RACKET STIF FENER 7 047411 2 SCREW HHC M6-1 .
.
1 0F6322 1 BOTTOM PLATE, AIR CLEANE R 3.9L 2 0F5418 1 ELEMENT AIR FILTE R 3 0E6406 1 HOLDER VE NTURI 4 0E 770 2 1 HOL D D OWN AI R CLE AN ER 5 0F6323 1 PLATE, AIR CLEANER TOP 3.9L 6 03756 1 1 NUT WING 1/4-20 NYLK 7 04981 5 4 SCREW HHC M5-0.8 X 16 G 8.
.
1 03 321 2 4 SCRE W HH C 5/ 16- 18 X 1-1/ 4 G 5 2 075580 1 FLANGE FUEL IN LET 3 0F6 3 90 1 RE GU L AT O R AS S EM BLY DU AL FUE L 4 03 9253 2 S CREW HHC M 8-1.2 5 X 20 G8.8 5 02 2145 2 W ASHE R FLAT 5/16-M 8 ZI NC 6 02 2129 6 WAS HER L OCK M 8-5/ 16 7 04 5771 2 NUT HEX M 8-1.
.
1 0F585 3 (XX) 1 RE AR WR AP C2 2 0C 24 5 4 68 S CR EW T HF M6- 1 X 16 N WA Z/ JS 3 0F584 9 (XX) 2 DO OR C2 4 087233 2 RIVET POP .1875 X .4 50 SS 5 0E3 257 4 SCREW TH-F RM M 6 W/CA P SHK PRF W 6 0F 5 .
.
.
.
.
.
.
Standby Generator Sets W arranty Printed in U.S.A. GENERA C PO WER SYSTEMS ST ANDARD LIMITED W ARRANTY FOR HOME ST ANDBY/LIGHT COMMERCIAL PRODUCT 45kW AND BELO W For a period of two (2) y ears from the date of sale, or start-up by A uthorized/Cer tified Generac P ower Systems Dealer , or branch thereof , Generac P ow er Systems, Inc.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Generac Power Systems 005223-0 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Generac Power Systems 005223-0 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Generac Power Systems 005223-0, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Generac Power Systems 005223-0 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Generac Power Systems 005223-0, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Generac Power Systems 005223-0.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Generac Power Systems 005223-0. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Generac Power Systems 005223-0 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.