Manuel d'utilisation / d'entretien du produit 9801-7 du fabricant Generac
Aller à la page of 24
Owner’s Manual Questions? Help is just a moment a wa y! Call: Generac Generator Helpline - 1-800-270-1408 M-F 8-5 CT W eb: www .g enerac-por tables.com or www .briggsandstratton.com Model No . 9801-7 (10,000 W att A C Generator) Manual No. 189484GS Re vision 2 (09/24/2002) Safety Rules .
10000EXL Extended Life Generator 2 EQUIPMENT DESCRIPTION Read this manual car efully and become familiar with your g enerator . Know its a pplications, its limitations and any hazar ds inv olved. This generator is an engine–driven, r evolving field, alternating curr ent (AC) generator .
3 10000EXL Extended Life Generator WHEN ADDING FUEL • T urn generator OFF and let it cool at least 2 minutes befor e remo ving gas cap. Loosen cap slowly to r elieve pressur e in tank. • Fill fuel tank outdoors. • DO NO T ov erfill tank. Allow space for fuel expansion.
10000EXL Extended Life Generator 4 Y our generator requires some assembl y and is ready for use after it has been properl y ser viced with the recommended oil and fuel. If you ha v e any pr oblems with the assembly of y our generator , please call the generator helpline at 1-800-270-1408.
8. Attach the vibration mounts to the support leg with a 30mm capscr ew and lock nut. 9. With the wheels on, secure the support leg assembly to the cradle with 20 mm long capscr ews, flat washers, and lock washers. 10. Check each fastener to ensure it is secur e and the tires ar e inflated between 15-40 PSI.
10000EXL Extended Life Generator 6 KNO W Y OUR GENERA T OR Read this o wner’ s manual and safety rules before operating y our generator . Compare the illustrations with y our generator , to familiarize yourself with the locations of various contr ols and adjustments.
7 10000EXL Extended Life Generator GR OUNDING THE GENERA T OR The National Electrical Code requir es that the frame and external electrically conductiv e par ts of this generator be properl y connected to an appro ved earth ground. Local electrical codes ma y also requir e additional grounding of the unit.
10000EXL Extended Life Generator 8 5A. For electric starting, press start switch on generator cradle. T o pr olong the life of the star ter components, press the starter button for no mor e than 15 seconds, and pause for 30 seconds. 5B. For manual starting, grasp the recoil handle and pull slowly until slight r esistance is felt.
9 10000EXL Extended Life Generator • Start engine . Let the engine run while batter y recharges. • When batter y has charged, shut down engine NO TE: Use an automotive h ydrometer to test battery state of charge and condition. Follow the h ydrometer manufactur er’ s instructions car efully .
10000EXL Extended Life Generator 10 120/240 V olt A C , 30 Amp , Locking Receptacle Use a NEMA L14–30 plug with this receptacle. Connect a 4–wire cor d set rated for 250 V olt A C loads at 30 Amps (or greater) (Figur e 12). Y ou can use the same 4–wire cor d if you plan to run a 120 V olt load.
11 10000EXL Extended Life Generator 120 V olt, 20 Amp Locking T ype Receptacle Use a NEMA L5–20 plug with this receptacle. Connect a 3–wire cor d set rated for 125 V olt A C loads at 20 Amps to the plug (Figure 14). Use this receptacle to operate 120 V olt A C , 60 Hz, single phase loads requiring up to 2,400 watts (2.
10000EXL Extended Life Generator 12 DON'T O VERLO AD Y OUR GENERA T OR Capacity Y ou must make sur e your generator can supply enough rated (running) and surge (starting) watts for the items you will pow er at the same time . Follow these simple steps: 1.
13 10000EXL Extended Life Generator SPECIFICA TIONS Maximum Surge W atts . . . . . . . . . . . . . . . .12,500 watts Continuous W attage Capacity . . . . . . . . . .10,000 watts P ower Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10000EXL Extended Life Generator 14 ST ORA GE The generator should be started at least once every seven da ys and allowed to run at least 30 min utes. If this cannot be done and you m ust store the unit for mor e than 30 da ys, use the follo wing guidelines to prepare it f or storage.
15 10000EXL Extended Life Generator TR OUBLESHOO TING Problem Cause Correction Engine is ru nning, but no AC output is a vailable. 1. One of the circuit brea kers i s open. 2. Fault i n generator. 3. Poor co nnection or defe ctive cord set . 4. Con nected devi ce is bad.
10000EXL Extended Life Generator 16 SCHEMA TIC.
17 10000EXL Extended Life Generator WIRING DIA GRAM.
10000EXL Extended Life Generator 18 EXPLODED VIEW – MAIN UNIT.
19 10000EXL Extended Life Generator Item P ar t # Qty Description 1 NSP 1 ENGINE 2 JB4509A GS 1 SHIELD , Heat 3 A77304GS 2 SUPPOR T , Engine 4 JB5567GS 1 SHIELD , Heat 5 80270GS 1 V AL VE, Fuel Shut-O.
10000EXL Extended Life Generator 20 EXPLODED VIEW – CONTROL P ANEL.
21 10000EXL Extended Life Generator P AR TS LIST – CONTR OL P ANEL Item Part # Qty Description 1 AB4432GS 1 P ANEL, Control 2 B95906GS 1 BO X, Control 3 43437GS 1 OUTLET , 120/240V , 30A Locking 4 6.
10000EXL Extended Life Generator 22 EXPLODED VIEW AND P AR TS LIST – WHEEL KIT Item Part # Qty Description 1 BB5586GS 2 HANDLE (Includes Item 2) 2 B4605GS 2 GRIP 3 39287GS 2 SCREW 4 22145GS 6 W ASHE.
23 10000EXL Extended Life Generator EXPLODED VIEW AND P AR TS LIST – AL TERNA T OR Item Part # Qty Description 1 B4906GS 1 SHIELD , Fr ont 2 B4907GS 2 GRID , Fr ont 3 B4908GS 1 BOL T , Shaft Sta y 4.
LIMITED W ARRANTY GENERA C POR T ABLE PRODUCTS O WNER W ARRANTY POLICY Effectiv e October 1, 2001 W ARRANTY PERIOD* * The warranty period begins on the date of purchase b y the first retail consumer or commercial end user , and continues for the period of time stated in the table abov e .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Generac 9801-7 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Generac 9801-7 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Generac 9801-7, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Generac 9801-7 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Generac 9801-7, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Generac 9801-7.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Generac 9801-7. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Generac 9801-7 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.