Manuel d'utilisation / d'entretien du produit 004912-0, 004912-1, 004913-0, 004913-1 du fabricant Generac
Aller à la page of 52
Owner’ s Man ual Liquid-cooled, Prepac kaged Standby Generator s Models: 004912-0, 004912-1 (15 kW LP/15 kW Natural Gas) 120/240V Single-phase w/ 100 Amp T ransfer Switch 004913-0, 004913-1, 004913-.
Generac ® Pow er Systems, Inc. I NTRODUCTION Thank you for purchasing this model of the standby generator product line by Generac P ower Systems. Every effort was expended to make sure that the information and instructions in this manual are both accurate and current at the time the manual was written.
T able of Contents Centurion Liquid-cooled 1 5 kW and 25 kW Generators Generac ® Pow er Systems, Inc. 1 Introduction ................................Inside Front Cover Read This Manual Thoroughly ............................IFC Operation and Maintenance .
2 Generac ® Pow er Systems, Inc. Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reliably only if it is properly installed, operated and maintained.
Generac ® Pow er Systems, Inc. 3 • Before performing any maintenance on the generator , disconnect its battery cables to prevent accidental start -up. Disconnect the cable from the battery post indicated by a NEGA TIVE, NEG or (–) first. Reconnect that cable last.
4 Generac ® Pow er Systems, Inc. 1.1 GEN ER A T OR This equipment is a liquid- cooled, engine - driven generator set. The generator is designed to supply electrical power that operates critical electrical loads during utility power failure.
Generac ® Pow er Systems, Inc. 5 1.5 MAI N CI RCU IT B R EAKER The generator’s main circuit breaker is included with the unit. The breaker for each unit is described in Figure 1.2. 1.6 GEN ER A T OR F U EL S YS TEM The generator has been factory tested and adjusted using a natural gas fuel system.
6 Generac ® Pow er Systems, Inc. Figure 1.5- High Coolant T emperature Switch 1.7 .3 L OW C OOL ANT LEVEL SWIT CH Should engine coolant level drop below the level of the high coolant temperature switch, it is possible for the engine to overheat without automatic shutdown.
1.1 0 SP E CI F ICA TIONS 1.1 0.1 GEN ER A T OR 1.1 0.2 ENGI N E Make ................................................................Mitsubishi Displacement ..................................92 inches 3 (1.5 liters) Cylinder Arrangement .............
8 Generac ® Pow er Systems, Inc. Serious injury or damage may occur if not configured pr operly . Please consult an authorized Generac Service Dealer with any questions. 1.1 3 T ORQU E SP E CI F ICA TIONS Cylinder Head ...............................
Generac ® Pow er Systems, Inc. 9 NOTE: F or more information about the installation of a standby system, you can order Engine - Generator Standby Electric P ower Systems Installer’s Guide and Reference Manual (part #046622) from a Generac Authorized Service Dealer .
10 Generac ® Pow er Systems, Inc. Figure 2.1 – Basic Standby Electric System NOTE: Generac recommends the use of a Generac P ower Systems transfer switch in conjunction with this generator .
Generac ® Pow er Systems, Inc. 11 2.8 GEN ER A T OR A C N EUTR AL CO N N EC T I O N S Generac uses an UNGROUNDED AC neutral. Grounding is recommended only at the main service entrance. If the neutral wire is grounded and one of the phase loads becomes grounded, the excessive current opens the load circuit breaker or collapses the generator field.
12 Generac ® Pow er Systems, Inc. When using maintenance -free batteries, it is not necessary to check the specific gravity or electrolyte level. Have these procedures performed at the intervals specified in Section 4, “Maintenance.” A negative ground system is used.
Generac ® Pow er Systems, Inc. 13 3.1 USI NG A S T AN D AR D “GT S” TR ANSF ER SWIT CH When required, the pre -packaged standby generator can be installed with an engineered Generac “GTS” type engineered automatic transfer switch.
14 Generac ® Pow er Systems, Inc. 3.2.5 7 .5 AM P I N-LI N E FUSE This in-line fuse is connected in wire 15A which runs between the A UTO/OFF/MANUAL switch and position 10 of the 076009A PCB.
Generac ® Pow er Systems, Inc. 15 Figure 3.3 - Engine Block Heater Refer to applicable wiring diagram(s) and electrical schematic(s) at back of manual for wiring connections. Customer supplies a 120V 15A Utility fed circuit for the block heater . 4.1 MAI NTENANCE P ER FOR M ED B Y AUTHOR IZED SERVICE F A CI LITI E S A.
16 Generac ® Pow er Systems, Inc. Section 4 — Maintenance Centurion Liquid-cooled 1 5 kW and 25 kW Generators Figure 4.1 - Oil Dipstick and Oil Fill Cap 4.4.2 BA T TER Y F L U I D Check battery electrolyte fluid at least once weekly . Fluid should cover separators in all battery cells.
Generac ® Pow er Systems, Inc. 17 1. Remove OIL DRAIN HOSE from its retaining clip. 2. Loosen and remove OIL DRAIN HOSE CAP . Drain oil completely into suitable container . 3. When all oil has drained, install and tighten OIL DRAIN HOSE CAP , and re -install into its retaining clip.
18 Generac ® Pow er Systems, Inc. Once each year , have the generator cleaned and inspected by an Authorized Service Dealer . That dealer will use dry , low pressure air to clean internal windings. P arts inside the control console should be cleaned and inspected at this time as well.
Generac ® Pow er Systems, Inc. 19 1. The base frame of the unit contains an optional fuel inlet location that is capped at the factory . Check that it is secured in place. The same applies for any access ports in the roof of the enclosure. If any of these caps are missing, contact a Generac Authorized Dealer .
20 Generac ® Pow er Systems, Inc. Section 4 — Maintenance Centurion Liquid-cooled 1 5 kW and 25 kW Generators 4.9 S CH EDU LED MAI NTENANCE The following is a recommended maintenance schedule for Centurion small standby and residential generator sets.
Generac ® Pow er Systems, Inc. 21 Section 4 — Maintenance Centurion Liquid-cooled 1 5 kW and 25 kW Generators Maintenance Le vel 1 Le vel 2 Level 3 Level 4 T asks Recom- T ask Required T ask Required T ask T ask mended Comp . to be done Comp . to be done Comp.
22 Generac ® Pow er Systems, Inc. Section 4 — Maintenance Centurion Liquid-cooled 1 5 kW and 25 kW Generators Maintenance Le vel 1 Le vel 2 Level 3 Level 4 T asks Recom- T ask Required T ask Required T ask T ask mended Comp . to be done Comp . to be done Comp.
Generac ® Pow er Systems, Inc. 23 Section 5 — T roubleshooting Centurion Liquid-cooled 1 5 kW and 25 kW Generators 5.1 TROU B LE SHOO TI NG POI NTS P ROBLEM CAUSE CORR E CTION Engine won’t crank. 1. 15 amp fuse blo wn. 1. Replace fuse. 2. Loose or corroded or def ective 2.
24 Generac ® Pow er Systems, Inc. Section 6 — Notes Centurion Liquid-cooled 1 5 kW and 25 kW Generators.
Generac ® Pow er Systems, Inc. 25 Section 7 - Installation Diagram Centurion Liquid-cooled 1 5 kW and 25 kW Generators Drawing No. 0E1 533-A.
NB S ET EXER C I S E S WIT CH TERMINAL S TRIP 7 P OS. V O LTA G E RE GU LAT OR VR T S3 - - S W 2 - FL - SU PRE SS I O N A SS EMBL Y NE U TRAL BL OCK FA U LT LI G H T H OU R METE R F US E 1 5 AMP S FIE.
Generac ® Pow er Systems, Inc. 27 Section 8 - Electrical Data Centurion Liquid-cooled 1 5 kW and 25 kW Generators Wiring Diagram — 1.5L Engine — Drawing No.
28 Generac ® Pow er Systems, Inc. Section 8 - Electrical Data Centurion Liquid-cooled 1 5 kW and 25 kW Generators Wiring Diagram — 1.5L Guardian — Drawing No.
Generac ® Pow er Systems, Inc. 29 Section 8 - Electrical Data Centurion Liquid-cooled 1 5 kW and 25 kW Generators Electrical Schematic — 1.5L — Drawing No.
ITEM P AR T NO . QTY . DESCRIPTION 1 098290 1 ASM MO T OR STEPPER 2 098941A 1 HOUSING GO VERNOR CONNECT OR 3 098958A REF CONNECT OR INTERF ACE ASSEMBL Y 4 098942A 1 CO VER CONNECTOR HOUSING 5 098225 2 SCREW FHM #2 X 5/8 SELF T AP 6 043146 3 SCREW HHC M6-1.
ITEM P AR T NO . QTY . DESCRIPTION 1 0D8656 1 BASE,MOUNTING 1.5L STNRD&ACSTC 2 027482 2 W ASHER SHAKEPROOF EXT 5/16 STL 3 070936 2 D AMPENER VIBRA TION 4 070936C 2 VIB. ISO. 70-75 DURO 5 039253 8 SCREW HHC M8-1.25 X 20 G8.8 6 022145 12 WASHER FLA T 5/16 ZINC 7 022129 16 WASHER LOCK M8-5/16 8 045771 4 NUT HEX M8-1.
32 Generac ® Pow er Systems, Inc. N U T S ITEM #2 6. US E L OC TITE ON PANEL FOR ACCESS COVER E WELD S T U D U NDER R OOF 17 G R OU ND WIRE . FA S TENER T O S E CU R E US E D OO R LAT CH N O TE : 11 .
ITEM P AR T NO . QTY . DESCRIPTION 1 0D8666 1 ROOF A CSTC&STND CMPR TMNT 1.5L 2 0D8664C 1 DUCT CENTER 1.5L 3 0D8657 1 SUPPORT RADIA T OR 1.5L MITSU 4 0D8660 2 BRACE SIDE 1.5L MITSU 5 0A7568 2 DOORWELDMENT 1.5EPS 6 0D8659 1 CORNER POST REAR RH SIDE 1.
34 Generac ® Pow er Systems, Inc. T YPI C AL O F FR O NT D UC T & R OOF P ANEL. S E CU RE A S S H O WN. PANEL FOR ACCESS COVER CABLE W ELD S T U D U NDER R OO F US E D OO R LAT C H NO TE: 24 38 4.
Generac ® Pow er Systems, Inc. 35 ITEM P AR T NO . QTY . DESCRIPTION 1 0D8666 1 ROOF A CSTC & STND CMPR TMNT 1.5L 2 0D8664C 1 DUCT CENTER 1.5L 3 0D8657 1 SUPPORT RADIA T OR 1.5L MITSU 4 0D8660 2 BRACE SIDE 1.5L MITSU 5 0A7568 2 DOOR WELDMENT 1.5 EPS 6 0D8659 1 CORNER POST REAR RH SIDE 1.
36 Generac ® Pow er Systems, Inc. Section 9 - Exploded Views and P arts Centurion Liquid-cooled 1 5 kW and 25 kW Generators Control Panel — Drawing No.
Generac ® Pow er Systems, Inc. 37 ITEM P AR T NO . QTY . DESCRIPTION 1 0D9322 1 P ANEL BACK & BO TTOM GU ARDIAN 2 0D9332 1 P ANEL LH SIDE GUARDIAN & SPRN 3 0D9325A 1 P ANEL FRONT CONTR OL GU ARDIAN W/ SILKSC 4 0D9330 1 P ANEL RH SIDE C-P ANEL SML BRK 5 0C1457 1 HOURMETER 6 064009 1 LIGHT 12VDC .
6 1 WATERPUMP HARDWARE 13 9 10 11 2 8 7 12 24 10 14 15 16 6 32 5 4 1 24 39 41 30 17 11 10 14 11 19 17 18 20 26 21 20 25 22 24 5 7 33 1 1 14 9 24 72 10 11 10 14 1 24 35 3 4 36 44 45 14 71 12 46 11 10 4.
ITEM P AR T NO . QTY . DESCRIPTION 1 0A4531 1 ENGINE-1.5L 2 022473 2 W ASHER FLA T 1/4 ZINC 4 0A45310258 1 GASKET -EXHAUST MANIFOLD 5 0A4355 1 MANIFOLD-EXHA UST 6 0E2632 1 HEA T SHIELD EXH 1.5L 7 022097 8 W ASHER LOCK M6-1/4 8 022507 2 SCREW HHC 1/4-20 X 1/2 G5 9 052212 2 SCREW HHC M10-1.
14 11 17 28 ( BOTTOM ONLY ) "A " 28 22 9 30 3 2 29 10 2 21 1 3 2 3 35 18 14 12 33 17 34 4 TO WATER INLE T ( MIDWAY UP ENGINE BLOCK ) 14 TUBE (ON BLOCK) TO THERM OS TAT 3 1 10 23 26 8 20 WATE.
ITEM P AR T NO . QTY . DESCRIPTION 1 0D8657 1 SUPPORT RADIA T OR 1.5L MITSU 2 0A5734 1 RADIA T OR 1.5L 3 0A6237 1 VENTURI 1.5L MODINE 4 * 0A6238 1 GUARD F AN 1.5L MODINE 5 084918 1 HEA TER ENGINE 0500W 120V 6 051520N 1 TUBING 5/8 ID X 12 7 048031C 4 CLAMP HOSE BAND 1/4 8 099502 4 CLAMP HOSE #24 B1.
42 Generac ® Pow er Systems, Inc. 2 9 33 32 31 1 8 2 0 1 0 1 9 L.P. VAP OR P O R T " OU T 2 " 41 4 0 11 14 9 " C" 12 14 1 6 17 8 4 3 1 5 " D" 4 5 27 42 2 3 2 7 6 4 0 21 .
Generac ® Pow er Systems, Inc. 43 ITEM P AR T NO . QTY . DESCRIPTION 1 * --------- 1 WELDMENT MOUNTING BASE 2 075580 1 FLANGE FUEL INLET 3 0E1006 1 ASSY REGULA T OR 1.5L N.G.OR LPV 4 039253 2 SCREW HHC M8-1.25 X 20 G8.8 5 022145 2 W ASHER FLA T 5/16 ZINC 6 022129 6 W ASHER LOCK M8-5/16 7 045771 2 NUT HEX M8-1.
44 Generac ® Pow er Systems, Inc. 8 36 13 3 12 5 9 15 14 17 T o Blow e r H ousin g 3 2 2 3 24 35 1 21 28 7 22 33 10 29 16 30 18 2 6 19 20 3 1 2 1 4 T o En g ine C rankshaf t 26 Section 9 - Exploded Views and P arts Centurion Liquid-cooled 1 5 kW and 25 kW Generators Alternator — Drawing No.
Generac ® Pow er Systems, Inc. 45 ITEM P AR T NO . QTY . DESCRIPTION 1 098671 1 ASSY RO TOR 10KW 098681 1 ASSY RO TOR 15KW 098675 1 ASSY RO TOR 20KW 098936 1 ASSY RO TOR 25KW 2 0A5336A 1 HOUSING BLOWER 3 0A1659 1 SCREEN AIR OUTLET 4 071912 4 SCREW PPHM M5-0.
ITEM P AR T NO . QTY . DESCRIPTION 1 077483 1 BA TT 12VDC 75-AH 26 2 038804D 1 CABLE BA TT RED #4 X 20.00 3 038805B 1 CABLE BA TT BLK #4 X 23.00 4 0742600131 1 ASSY ,WIRE#16 RED 1.6 5 022131 1 W ASHER FLA T 3/8 ZINC 6 046526 1 W ASHER LOCK M10 7 052213 1 SCREW HHC M10-1.
Generac ® Pow er Systems, Inc. 47 ITEM P AR T NO . QTY . DESCRIPTION 1 0A4355 1 MANIFOLD EXHAUST 1.5L 2 0E2844 1 NIPPLE T OE 1.5NPTX5.5 BLK IRON 3 036434 3 BOL T U 5/16-18 X 2.09 036449 3 SADDLE 2 INCH 4 0E0109 1 PIPE,EXHAUST 1.5L STNDRD&A CSTC 5 0C1318 1 FLEX PIPE EXHA UST 6 0D8657 1 SUPPORT , RADIA T OR 1.
48 Generac ® Pow er Systems, Inc. CALI FOR N IA EM ISSION C ONTROL W AR R ANT Y ST A TEM ENT Y OU R W AR R ANT Y R IGHT S AN D OBLIGA TIONS The California Air Resources Board (CARB) and Generac P ower Systems, Inc. (Generac) are pleased to explain the Emission Control System W arranty on your new engine.
Generac ® Pow er Systems, Inc. 49 EM IS SION CONTROL S YS TEM W AR R ANT Y Emission Control System W arranty (ECS W arranty) for 1995 and later model year engines: (a) Applicability: This warranty shall apply to 1995 and later model year engines.
Part No. 0E5129 Revision G (12/20/04) Printed in U.S.A. Section 1 0 – Warranty Centurion Liquid-cooled 1 5 kW and 25 kW Generators GENER AC PO WER SY STEMS "TWO YEAR" LI MITED W AR RANT Y .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Generac 004912-0, 004912-1, 004913-0, 004913-1 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Generac 004912-0, 004912-1, 004913-0, 004913-1 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Generac 004912-0, 004912-1, 004913-0, 004913-1, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Generac 004912-0, 004912-1, 004913-0, 004913-1 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Generac 004912-0, 004912-1, 004913-0, 004913-1, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Generac 004912-0, 004912-1, 004913-0, 004913-1.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Generac 004912-0, 004912-1, 004913-0, 004913-1. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Generac 004912-0, 004912-1, 004913-0, 004913-1 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.