GE Monogram ® Installation Instr uctions 36" Downdraft Gas Cooktops Models ZGU365.
CAUTION 2 Before you begin—Read these instr uctions completely and carefully . IMPORT ANT: Save these instr uctions for local inspector’s use. IMPORT ANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES. NOTE TO INST ALLER: Be sure to leave these instr uctions with the Consumer .
3 Models Available ZGU365 36" gas downdraft cooktops Design Infor mation G a s D owndraf t Co ok top These models are shipped for natural gas operation. They can be converted to liquid propane. (Order JXLP56 conversion kit.) These gas downdraft cooktops are equipped with an vent system which can be retracted when not in use.
4 Design Infor mation G a s D owndraf t Co ok top Advance Planning Clearances • The downdraft system with blower , motor and ductwork will occupy the cabinet below the cooktop.
5 Cut the Opening Cabinetr y/Ductwork G a s D owndraf t Co ok to p Measure carefully when cutting countertop. Make sure sides of opening are parallel and rear and front cuts are exactly perpendicular to sides. • The Monogram gas downdraft cooktop is designed to fit in a 36" or larger base cabinet.
6 Ductwork G a s D owndraf t Co ok top V enting Options • The downdraft vent is shipped with the discharge outlet pointing straight down and can be changed to the left or right side. • The blower outlet is sized for 3-1/2" x 10" and can be transitioned to 6" round.
7 Ductwork G a s D owndraf t Co ok top Duct Fittings T otal Equivalent Quantity Equivalent Duct Piece Dimensions Length* Used Length 1 ft. 6" round, (per foot straight length) 1 ft. 3 -1 ⁄ 4" x 10" (per foot straight length) 6" 90 ° elbow 15 ft.
8 Gas and Electrical Supply G a s D owndraf t Co ok top Gas supply: These cooktops are designed to operate on natural gas at 4" of water column pressure or on LP gas at 10" of water column pressure. – These cooktops are shipped from the factor y set for natural gas.
9 Installation G a s D owndraf t Co ok top Remove Packaging • Remove the shipping materials and the carton, set carton aside. The carton can be used as a pad when changing or adjusting vent direction. • Remove the plastic ties on both ends at the top of the vent.
10 Installation G a s D owndraf t Co ok top • Install the supplied pressure regulator and nipple in the gas line as close to the cooktop inlet as possible. Allowances for ventilation ducting may be necessar y . –Make sure the regulator is installed in the right direction.
11 Installation G a s D owndraf t Co ok to p Note: If the cooktop is installed into a 36" base cabinet, the pressure regulator MUST BE installed to the bottom of the cooktop before the cooktop is placed into the cabinet. • Remove packaging from the cooktop.
12 Installation G a s D owndraf t Coo k top 5 Electrical Connections Step • Connect the 3-pin plastic plug from the blower/motor assembly to the 3-pin plastic socket on the underside of the vent, next to the conduit. • Slide the metal cover over the connection and secure with screws.
13 Installation G a s D owndraf t Co ok top T o raise the vent, tur n the VENT knob to RAISE/LOWER. • Hold the knob until the vent begins to raise. – The vent will automatically stop when it is fully extended. • T ip filter into the opening and pull straight down so that the filter rests on slides.
14 JXRB57 Kit For Indoor Remote Blower Locations Tools and Materials required: • Pencil • Measuring tape • Drill with appropriate bits • Nut driver • Junction box • Wire nuts • Safety glasses • 3-1/4" x 10" to 6" round transition.
15 JXRB57 Kit For Indoor Remote Blower Locations • Remove the 4 nuts holding the blower to the mounting plate. One nut is hidden inside the outlet. Remove blower . • Remove the blower mounting plate. • Remove 2 screws along the bottom of the blower box which are visible once blower plate is removed.
16 4 Connect Electrical Step 3 Connect Ductwork Step JXRB57 Kit For Indoor Remote Blower Locations Duct Adapter Outlet Cover Downdraft • The downdraft plenum can discharge from either the right or left side. Select the side that provides the best alignment to ductwork extending to the blower assembly below .
17 JXBC57 Kit For Outdoor Remote Blower Locations Materials Required (not supplied) • Approved liquid tight service connections for use between the wire compartment on the base and inside the structure. • 7 wire nuts or other approved connectors. • Six 5/16" dia.
18 JXBC57 Kit For Outdoor Remote Blower Locations 2 Mark Mounting Location Step • The base is designed to be mounted to studs on 16" centers. Use the dimensions shown to deter mine the location of the ducting and wiring through the wall.
19 JXBC57 Kit For Outdoor Remote Blower Locations 3 (continued) Step • Remove the 4 nuts holding the blower to the mounting plate. One nut is hidden inside the outlet. Remove blower . • Remove the blower mounting plate. • Remove 2 screws along the bottom of the blower box which are visible once blower plate is removed.
20 JXBC57 Kit For Outdoor Remote Blower Locations 5 Connect Electrical Step • Use electrical cable and connectors that conform to local codes (14 gauge min. is recommended). Use a length to reach between the vent and the blower/motor location. • Attach the wire box removed from the blower conduit to the end of new wiaring.
21 Notes.
22 Notes.
23 Notes.
NOTE: While performing installations described in this book, safety glasses or goggles should be worn. T o obtain specific information concerning any Monogram product or service, call GE Answer Center ® consumer information service at 800.626.2000—any time, day or night.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté GE Monogram ZGU365 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du GE Monogram ZGU365 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation GE Monogram ZGU365, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le GE Monogram ZGU365 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le GE Monogram ZGU365, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du GE Monogram ZGU365.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le GE Monogram ZGU365. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei GE Monogram ZGU365 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.