Manuel d'utilisation / d'entretien du produit 3500 du fabricant GE
Aller à la page of 28
49-7415-2 JR 06-01 Air Con di t i o n ers Safety Instr uctions . . . . . . . . . . .2 Operating Instr uctions Air Direction . . . . . . . . . . . . . . . .4 Auxiliary Controls . . . . . . . . . .5–9 Controls . . . . . . . . . . . . . . . . . . . .3 V ent Control .
Customer Service T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions IMPORT ANT SAFETY INFORMA TION. READ ALL INSTRUCTIONS BEFORE USING.
Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Customer Service 3 Controls Mode Control HIGH COOL and AUTO COOL provide cooling with different fan speeds. HIGH HEA T and AUTO HEA T provide heating with different fan speeds.
Customer Service T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions V entilation Control The ventilation control lever is located at the upper left side of the Zoneline unit, behind the room cabinet. NOTE: The vent door shipping hardware must be removed before using the vent control lever .
5 Auxiliary Controls on your Zoneline. www .GEAppliances.com Auxiliary Controls – Dip Switches The auxiliary dip switch controls are located behind the room cabinet, through an opening in the control panel. Remove the room cabinet. See the T o Remove the Room Cabinet section.
6 Auxiliary controls on your Zoneline. Remote Thermostat–Class 2 When this switch is enabled (UP) , it allows the unit to operate off of a Class 2 Remote Control W all Thermostat. The unit controls are disabled. Load Shedding (CDC) This feature is active only if the unit is in CDC mode.
7 www .GEAppliances.com T emperature Limiting T emperature limiting can reduce energy costs by limiting the lowest temperature that can be set for cooling and the highest temperature that can be set for heating. T emperature limiting is controlled by the second six auxiliary switches.
8 Customer Service T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions Auxiliary controls on your Zoneline. Auxiliary Controls–T erminal Connections The auxiliary controls are located behind the room cabinet beneath the control panel.
9 Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Customer Service www .GEAppliances.com Door Sensor (Obtained locally) When connected, the door sensor will detect when the door in the room was opened or closed. This feature must be used in conjunction with the motion sensor .
Customer Service T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions 10 Care and cleaning. Base Pan In some installations, dirt or other debris may be blown into the unit from the outside and settle in the base pan (the bottom of the unit).
Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Customer Service 11 T o maintain optimum performance, clean the filters at least every 30 days. Air Filters T urn the Zoneline off before cleaning. The most important thing you can do to maintain the Zoneline is to clean the filter at least every 30 days.
BEFORE YOU BEGIN Installation Zoneline Air Instructions Conditioners Read these instr uctions completely and carefully . • IMPORT ANT – Save these instructions for local inspector’ s use. • IMPORT ANT – Obser ve all governing codes and ordinances.
13 Installation Instructions REPLACING AN EXISTING UNIT? Use the cor rect wall case This unit i s designed to be installed in a GE plastic or insulated metal wall case.
Installation Instructions 14 HOW TO CONNECT 1 Remove the room cabinet. 2 Connect to electrical power . 3 See the special instructions below for applicable supply voltages.
15 Installation Instructions 265 VOL T ELECTRICAL SUPPL Y W ARNING: Connection of this 265 V AC product to a branch circuit MUST be done by direct connection in accordance with the National Electric Code. Plugging this unit into a building mounted exposed receptacle is not permitted by code.
Installation Instructions 16 A TT ACH CONDUIT 1 Use the round knockout at the bottom of the junction box to attach conduit coming from the branch circuit. Remove the knockout, attach the conduit and bring wires into the junction box. Leave 6 ″ of wire free at the end of the conduit to allow connections to be made.
Installation Instructions 17 INST ALL THE W ALL CASE AND EXTERIOR GRILLE The RAB71 series or RAB77 wall case must be properly installed per instructions packed with the case. • Remove the corrugated stiffener and the outdoor protective panel. Use the slit in the outdoor panel as a handhold and push out.
INST ALL THE UNIT INTO THE W ALL CASE Slide the unit into the wall case and secure with four screws through the unit flange holes. 3 REPLACE THE ROOM CABINET Reinstall the room cabinet by hooking the top over the rail along the unit top (1), then pushing it in at the bottom (2).
Installation Instructions 19 OPTIONAL – DRAIN KIT INST ALLA TION Dr y Air 2500 Series models are designed to improve dehumidification by 25%. Since more moisture will be r emoved from the air , there is a greater possibility that water will drip fr om the wall case than with a standard unit.
Customer Service T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions Before Y ou Call For Service… T roubleshooting T ips Save time and money! Review the charts on the following pages first and you may not need to call for service.
Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Customer Service 21 Normal Operating Sounds Y ou may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high.
22 Notes. Customer Service T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions.
Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Customer Service 23 Notes..
24 Notes. Customer Service T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions.
25 General Electric Company W ar ranty Registration Department P .O. Box 32150 Louisville, KY 40232-2150 Please place in envelope and mail to: ✁ Cut here.
Consumer Pr oduct Ownership Registration Important Mail T oday! General Electric Company Louisville, Kentucky www.GEAppliances.com First Name Mr . ■ ■ Ms. ■ ■ Mrs. ■ ■ Miss ■ ■ Street Address City State Date Placed In Use Month Day Y ear Zip Code Apt.
Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Customer Service 27 Zoneline W arranty . For The Period Of: GE Will Replace: One Y ear Any part of the Zoneline which fails due to a defect in materials or workmanship.
Printed in China Consumer Support. GE Appliances W ebsite www .GEAppliances.com Have a question or need assistance with your appliance? T r y the GE Appliances W ebsite 24 hours a day , any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts, catalogs, or even schedule service on-line.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté GE 3500 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du GE 3500 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation GE 3500, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le GE 3500 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le GE 3500, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du GE 3500.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le GE 3500. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei GE 3500 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.