Manuel d'utilisation / d'entretien du produit GP-90 du fabricant Furuno
Aller à la page of 36
INST ALLA TION MA NUAL GPS NA VIGA TOR GP-90 1. EQUIPMENT LIS T ............................................................................................ 1 2. DISPLA Y UNIT ...........................................................................
SAFETY INSTR UCTIONS WARNING Do not work inside the equipment unless totally familiar with electrical circuits. Hazardous voltage which can cause electrical shock, burn or serious injury exists inside the equipment. Turn off the power at the mains switchboard before beginning the installation.
1 1. EQUIPM ENT LIST St a nd ard s Name Type Q'ty Ma s s (kg ) Remarks GP A-017S GP A-018S Antenna Uni t GP A-019S 1 Fo r DGPS GP-90-N Wi thout Be acon RX Display Unit GP-90-A 1 2.2 Wi th Be ac o n RX CP20-01900 W i th An te n n a Ca bl e In stallation Mate r i als CP20-01950 1 set See lists at end of ma nu a l .
2 2. DISPLA Y UNIT The display unit can be installed with either of f our m ethods as shown below. Ref er to the outline dra w in g at the end of m anual. • Locate the unit away fr o m exhaust pipes and vents. • The mounting location should be well v entilat ed.
3 3. A N T ENNA UNIT Mounting I nstall t he antenna uni t ref erri ng to the i nstall ation diagr am at en d of manual . When sel ecti ng a mounti ng locat ion for t he antenn a uni t, keep in m ind the f ollow ing poi nts. • S e l e c t a loca tion out of the radar beam.
3. ANTE NNA UNIT 4 How to attach the N-P- 8DF B conn ector Outer Sheath Ar mor Inner Sheath Shield Remo ve outer sheath and armor by the dimensions shown left. Expose inner sheath and shield by the dimensions shown left. Cut off insulator and core by 10mm.
5 4. WIRING The figure belo w sho w s the connection of cables on rear of display unit. Ground the display unit to prevent loss of sensitivity and mutual interference.
4. W IRI NG 6 Gr ounding T he displ ay unit c ontains sev er al CPUs. W hile they ar e operati ng, they radi ate nois e, w hic h can i nterfer e w ith ot her radio equi pment. G round the uni t as fol low s to prevent i t. • T he grounding w ir e should be 1.
7 5. INITI A L SETTINGS Checking Operation 1. T urn on the G P-90. 2. Confi rm that "OK" and "BEACO N RCVR I N S T ALLED" are di splay ed on the self -test display . Confirm that "BEACON RCVR INST ALLED" is displa yed when DGPS function is provided.
5. INITIAL SETTINGS 8 5. Press the [NU/ CU ENT ] key . 6. Press the [M ENU ESC] key . Manual D GPS setup Enter four di git I D number, f requency and baud rate of st ati on. 1. Press [M ENU ESC] , [9] and [7] to di splay t he DGPS S E T UP menu. 2. Pr ess S or T t o select DGPS M ODE and press W to select “INT BEACON”.
5. INIT IAL SETTINGS 9 Input/Out put Se tting The GP-90 can out put navigation inf ormation to external equipm ent. For exam ple, it can output position d ata to a radar or echo sounder for display on their d isplay screen. You can convert a Loran Plotter t o a GPS Plotter w it h position data from the G P- 90.
5. INITIAL SETTINGS 10 Da t a fo rmat an d dat a o utput av ai labili ty Ou t p ut data sent en ce of I E C 611 62-1 and NMEA 0183 Ver. 1.5/ 2. 0. AAM : W ay point arri v al alarm APB: Autopilot sente.
5. INITIAL SETTINGS 11 Input data s ente nce of NM EA 0183 V er. 1.5/2. 0 Checks um i s checked i f att ached, and i f any errors are f ound, the sent ence be comes i nval id.
5. INITIAL SETTINGS 12 AGF PA: A utopil ot inf ormati on from F URUNO autopi lot equipment s Port Input Out put DA T A 1 DA T A 2 N MEA 0183 Ver. 1.5 /2.0 AGFPA , DBT, DPT, HDG, HD M, HDT, MTW, TLL, VBW, VHW IE C 61 162-1/NME A 0183 V er .1.5/ V er .2.
5. INITIAL SETTINGS 13 DA T A 1 ou tp ut sett in g 1) Press [ MENU] , [9] and [3] . The DA TA 1, 3 O U T PUT SE T UP menu appe ars. Talker ID GP LC DE Output Data (00-90 sec) 100% 1. AAM:00 APA:00 APB:04 BOD:00 2. BWC:00 BWW:00 GGA:00 GLL:01 3. RMB:01 RMC:00 VTG:01 WCV:00 4.
5. INITIAL SETTINGS 14 DAT A 2 outp ut se tti n g 1) Press [ MENU] , [9] and [ 4]. T he DAT A 2 O U T PUT SET UP menu appear s. Talker ID GP LC DE Output Data (00-90 sec) 100% DATA2 OUTPUT SETUP MENU : Escape ENT : Enter Data Fmt. V1.5 : Select Setting shown here are default settings.
5. INITIAL SETTINGS 15 Setti ng D A T A 4 to D at a Output 1) Press [ MENU] , [9] and [5] . The DA TA 4 I/O SE T UP menu a ppears. D A T A 4 I/O SETUP 1/2 T o Ne xt Page ENT : Enter MENU : Escape Appears only when e xter nal DGPS receiver is used. D A T A 4.
5. INIT IAL SETTINGS 16 Setting DA T A 4 to “COM.” (general da ta) W ay point s and Routes data can be received f r om a personal co m puter, through the DAT A 4 port. 1) Press [ M ENU] , [9] and [5]. 2) Press ! or " to select DATA4. Level. 3) Press # or $ to select level of personal com puter; RS232C or RS422.
5. INIT IAL SETTINGS 17 14) Output dat a f rom the computer. W hen loading data is completed, t he cu rsor shift s to Stop. 15) Press the [ESC] key. Setting DA T A 4 to DGPS An external DGPS receiver can be connected t o the DATA 4 port. Follow the procedure b elow to setup the GP-90 according to t he specifications of the DG PS receiver.
18 6. OPTIONAL DGPS Beacon Recei ver Set GR-80 GP-90 GR-80 D ATA D ATA 4 NP Board JP3 Open TD-A TD-B RD-A RD-B GND RD-A RD-B TD-A TD-B GND 1 2 3 4 5 6 7 4 3 2 1 7 RS-422* RS-422 * This connection is required for L/L A uto mode of GR-80.
19 7 . T APING ANT ENNA UN I T GP A-018S Af ter i nserti ng the w hip ant enna to the ant enna base of GP A-018S, t ape the ante nna base and w hip ant enna wi th self -v ul cani zing t ape and viny l t ape to rei nforce t he w hip antenna. 1. Wrap t he ant enna j uncti on point w it h butyl 15 t a pe or the eq uival ent.
NAME OUTLINE Q'TY DESCRIPTION/CODE № PACKING LIST 20AX-X-9851 -4 GP-90-**-*1-**/GP-90-DUAL-**-*1-** 1/1 NAME OUTLINE Q'TY DESCRIPTION/CODE № ユニット UNIT .
NAME OUTLINE Q'TY DESCRIPTION/CODE № PACKING LIST 20AX-X-9852 -4 GP-90-**-*O-**/GP-90-DUAL-**-*0-** 1/1 NAME OUTLINE Q'TY DESCRIPTION/CODE № ユニット UNIT .
CODE NO. 004-372-420-00 TYPE CP20-01701 略 図 OUTLI NE 名 称 NAME 数量 Q'TY 用途/備考 REMA RKS 番 号 NO. 型名/規格 DESCR IPTIONS 1/1 -4 INSTALLATION MATERIALS 工事材料表 20AG-X-9405 変換ケーブル組品 CONVERT CABLE ASSY.
CODE NO. TYPE 略 図 OUTLI NE 名 称 NAME 数量 Q'TY 用途/備考 REMA RKS 番 号 NO. 型名/規格 DESCR IPTIONS 1/1 -2 INSTALLATION MATERIALS 工事材料表 20AG-X-9404 GP-8.
Apr. 18 '03 D-1.
Apr. 18 '03 D-2.
Apr. 18 '03 D-3.
Y . Hatai hatai 2005.12.19 11:57:12 +09'00' D-4.
Sep.29'05 D-5.
Feb. 19, '03 D-6.
Feb. 19, '03 D-7.
D-8.
1 A 34 B C 2 MASS kg DWG NO. DRAWN APPROVED SCALE CHECKED NAME 名称 TITLE FURUNO ELECTRIC CO., LTD. *1 IV-8sq. 50/60Hz,1φ 220/230VAC, DPYC-1.5 *1 100/110(115)/ 6 52 1 (-) (+) P .
.
The paper used in this manual is elemental chlorine free. FURUNO Authorized Distributor/Dealer FURUNO Authorized Distributor/Dealer 9-52 Ashihara-cho, 9-52 Ashihara-cho, Nishinomi y a 662-8580, JAPAN .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Furuno GP-90 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Furuno GP-90 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Furuno GP-90, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Furuno GP-90 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Furuno GP-90, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Furuno GP-90.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Furuno GP-90. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Furuno GP-90 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.