Manuel d'utilisation / d'entretien du produit CAT-5 Receiver Card PE1004CF du fabricant Altinex
Aller à la page of 13
SPECIAL APPLICATION MANUAL PART NUMBER: 400 - 0210 - 001 PE1004CF CAT - 5 RECEIVER CARD FOR PIONEER PLASMA EXPANSION USER’S GUIDE.
SPECIAL APPLICATION 400 - 0210 - 001 1 TA BLE OF CONTENTS Page PRECAUTIONS / SAFETY WA RNINGS ............... 2 GENERAL .......................................................... 2 INSTALLATION ................................................. 2 CLEANING .
SPECIAL APPLICATION 400 - 0210 - 001 2 PRECA UTIONS / SA FETY WA RNINGS 1 Please read this manual carefully before using your PE1004CF . Keep this manual handy for future reference. These safety instructions are to ensure the long life of your PE1004CF and to prevent fire and shock hazard.
SPECIAL APPLICATION 400 - 0210 - 001 3 AB OUT YOUR PE1004CF 2 PE1004CF CAT - 5 RECEIVER CARD FOR PIONEER PLASMA E XPANSION The PE1004CF CAT - 5 Receiver Card is designed to receive RGBHV/ YPbPr video and audio signals over twisted pair (CAT - 5) type cable.
SPECIAL APPLICATION 400 - 0210 - 001 4 DESCRIPTION OF PE1004CF 4 AP PLICA TION DIA GRA MS 5 DIA GRA M 1 : INPUT SELECTION AU TOMA TIC INPUT SELECTION S electing plasma Input 3 displays PE1004CF CAT -5 #1 Input image on the plasma Input 3. Selecting plasma Input 4 displays PE1004CF CAT - 5 #2 Input image on the plasma Input 4.
SPECIAL APPLICATION 400 - 0210 - 001 5 DIA GRA M 2 : TYPICA L SETUP TYPICA L A PPLICA TION RS-232 DA1930CT DA1931CT DA1930CT DA1930CT PE1004CF.
SPECIAL APPLICATION 400 - 0210 - 001 6 DIA GRA M 3 : INTERNA L VIEW PE100 4CF BLOCK DIA GRAM AUDIO SEPARATOR CLOCK GENERATOR AUDIO MODULATION EDGE CONNECTOR POWER CAT5 RJ45 AUDIO INPUT4 3.
SPECIAL APPLICATION 400 - 0210 - 001 7 DIA GRA M 4 : SWITCH SETTINGS SW2 EQUALIZATION EQ VIDEO EQUALIZATION Set SW2 to the HW position for hardware equalization. Set SW2 to the SW position for software equalization. HARDWARE CONTROL Install the jumper for default input.
SPECIAL APPLICATION 400 - 0210 - 001 8 INSTA LLING YOUR PE1004CF 6 Step 1. Use ESD safety precautions and always wear a ground strap when handling the PE1004CF expansion card. Step 2. Prepare the card per the drawing in Diagram 4. Set SW 2 for either hardware or software equalization control and set the power up default input.
SPECIAL APPLICATION 400 - 0210 - 001 9 1. [SIDn] This command sets the ID number of the unit. The default unit ID is zero. Command Format: [ SIDn ] n = Unit ID (n = # from 0 to 99) Example: Send the command [SID1] to the system.
SPECIAL APPLICATION 400 - 0210 - 001 10 7. [IN] This command is use d to select the PE1004CF input that will be directed to the plasma display’s active expansion input.
SPECIAL APPLICATION 400 - 0210 - 001 11 12. […S] This command will save the configuration command being sent to the PE1004CF into its nonvolatile memory. Example : Equalization If Input 4 is currently the active input, s end the command [EQ100S] to save the equalization value of 100 for this input.
SPECIAL APPLICATION 400 - 0210 - 001 12 Cause 3: Cable connections are incorrect. Solution: Make sure that the cables are connected properly. Also, make sure that the continuity and wiring are good. If there is still no sound present, see Cause 4. Cause 4: Destination amplifier has a problem.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Altinex CAT-5 Receiver Card PE1004CF c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Altinex CAT-5 Receiver Card PE1004CF - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Altinex CAT-5 Receiver Card PE1004CF, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Altinex CAT-5 Receiver Card PE1004CF va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Altinex CAT-5 Receiver Card PE1004CF, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Altinex CAT-5 Receiver Card PE1004CF.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Altinex CAT-5 Receiver Card PE1004CF. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Altinex CAT-5 Receiver Card PE1004CF ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.