Manuel d'utilisation / d'entretien du produit C120-E361-04EN du fabricant Fujitsu
Aller à la page of 36
.
.
C120-E361-04EN SP ARC ® Enterprise M4000/M5000/M8000/M9000 Server RCI Build Procedure.
.
C120-E361-04EN ABOUT THIS PRODUCT This product is designed and manufactured for use in standard applications such as office work, personal device, househol d appliance, and general industrial applications.
.
C120-E361-04EN i Preface 1 This manual explains the RCI build procedure of the SP ARC Enterprise M 4000/M5000/M8000/M9000 server . This manual is intended for authorized service personnel who perform mainte nance work of the server or field engineers.
ii C120-E361-04EN Preface SP ARC Enterprise Mx000 Servers Documentation The manuals li sted below are provided for reference. (a) Manuals on the W eb The latest versions of all t he SP ARC Enterprise Series manua ls are available at the follo wing websites: Global Site http://www .
C120-E361-04EN iii Preface (b) Documentation CD For the Documentation CD, please contact your local sales represen tative. - SP ARC Enterprise M4000/M5000 Serv ers Documentation CD (C120-E365) - SP ARC Enterprise M8000/M9000 Serv ers Documentation CD (C120-E364) .
iv C120-E361-04EN Preface Prompt Notations The notation used for prompts in th is manual is shown below .Syntax of the Command Line Interface (CLI) Synt ax of the Command Line Interface (CLI) The command syntax is described below .
C120-E361-04EN v Reader's Comment Form Reader's Comment Form.
vi C120-E361-04EN Reader's Comment Form FOLD AND T APE FOLD AND T APE BUSINESS REPLY MAIL FIRST -CLASS MAIL PERMIT NO 74 1 SUNNYV ALE CA NO POST AGE NECESSAR Y IF MAILED IN THE UNITED ST ATES POS.
C120-E361-04EN vii Content s Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . i Reader's Comment Form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
viii C120-E361-04EN Conten ts.
C120-E361-04EN ix Contents Figures Figure 1.1 Basic configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 Figure 1.2 Cluster configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
x C120-E361-04EN Conten ts.
C120-E361-04EN xi Contents T ables Table 1.1 Command list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-3 Table A.1The Error Status Code and Exp lanation . . . . . . . . . . . . . . . . . . . . . . . . .
.
C120-E361-04EN 1-1 CHAPTER 1 RCI Build Procedure This chapter explains the following items regarding the initial build procedure of the Remote Cabinet Interface (RCI) in the installation work.
1-2 C120-E361-04EN CHAPTER 1 RCI Build Procedure Figure 1.2 Cluster configuration Figure 1.3 Duplicat ed configuration Figure 1.4 Mixture of duplicated and unduplicated configurations RCI I/O unit RCI.
C120-E361-04EN 1-3 1.2 RCI command 1.2 RCI command RCI commands are used to display RCI configuration information and set node addresses. T o connect I/O units equi pped with RCI ports, a set up using RCI commands is required in addition to the connection with RCI cables.
1-4 C120-E361-04EN CHAPTER 1 RCI Build Procedure 1.3 RCI Setup This section explains the RCI setup for the following cases: z New setup for a single RCI Host and two RCI I/O units z New setup of two RCI Hosts z When an RCI I/O unit is added later z When a RCI Host is added later Remarks: Please refer to Appendix A, "T roubleshooting.
C120-E361-04EN 1-5 1.3 RCI Setup 4 Connect the main unit and I/O units with RCI cables (see Figure 1.5 ). Connect an RCI branching conne ctor to each of the RCI por ts, and connect them with RCI cables by using a daisy-chain connection. Connect an RCI terminating resistor to the branching connector at either end of the RCI connection.
1-6 C120-E361-04EN CHAPTER 1 RCI Build Procedure 1.3.2 New setup of two RCI Host s Figure 1.6 New set up of two RCI Hosts 1 Log in to the XSCF Shell. 2 On main unit A, exec ute the setrci -c stat comm and to display the RCI status. 3 V erify that the RCI address is 000f7fff .
C120-E361-04EN 1-7 1.3 RCI Setup 7 On main unit A, execute the setrci -c set command to make the settings of the host node. Since main unit A is the first unit, host_no is 1. 8 On main unit B, execute the setrci -c set command to make the settings of the host node.
1-8 C120-E361-04EN CHAPTER 1 RCI Build Procedure 1.3.3 When an RCI I/O unit is added later Figure 1.7 When an RCI I/O unit is added later 1 Connect the I/O unit to be added with an RCI cable by using a daisy-chain connection (see Figure 1.
C120-E361-04EN 1-9 1.3 RCI Setup 1.3.4 When a RCI Host is added later Figure 1.8 When a RCI Hosts is added later 1 Log in to the XSCF Shell. 2 On main unit B, which is to be added, execute the setr ci -c stat command to display the RCI status. 3 V erify that the RCI address is 000f7fff .
1-10 C120-E361-04EN CHAPTER 1 RCI Build Procedure 7 Execute the setrci -c addconfig comm and on main unit B to expand the RCI configuration. 8 Display the RCI status by executing the setrci -c stat command on main unit A. 9 V erify that the added main unit is incorporated.
C120-E361-04EN 1-1 1 1.3 RCI Setup Remarks: Up to 32 RCIs including the RC I main unit can be connected. Use the repeater function of the external power controller to extend the cable length used and to increase the number of connected RCI device. Note that the maximum RCI cable length is 150 meters.
.
C120-E361-04EN A-1 Appendix A T roubleshooting A This appendix explains how to deal with possible prob lems during the RCI setup. z In the Case Where Setrci Command E nded Abnormally and Displayed “Operation Failed Error S tatus: XX” z In the Case Where RCI Status of RCI Host Changes From ACTIVE to INACTIVE A.
A-2 C120-E361-04EN Appendix A T roubleshooting 20 Detected the duplicate RCI address in RCI I/O unit (Expansion file unit, External power controller). Pattern C 30 Detected the duplicate RCI address in RCI I/O unit (Line selector switch). Pattern F fd RCI construction cannot be co nstructed, or it was cancelled.
C120-E361-04EN A-3 A.1 In the Case Where Setrci Command Ended Abnorm ally and Displayed “Operation Failed Error S tatus: XX” Remedy p attarn z Pattern A 1 Check the RCI setup procedure, the RCI address value and the connection. 1 Check the setting of the RCI address and the duplicate of the RCI address by setrci -c stat command.
A-4 C120-E361-04EN Appendix A T roubleshooting A.2 In the Case Where RCI S t atus of RCI Host Changes From ACTIVE to INACTIVE Remarks: When this probl em has occurred, do not replac e the XSCF unit because it is not a failure of the XSCF unit. This problem is occurred by the mistake of the RCI construction procedure and the RCI connection.
.
Back Cover.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Fujitsu C120-E361-04EN c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Fujitsu C120-E361-04EN - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Fujitsu C120-E361-04EN, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Fujitsu C120-E361-04EN va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Fujitsu C120-E361-04EN, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Fujitsu C120-E361-04EN.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Fujitsu C120-E361-04EN. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Fujitsu C120-E361-04EN ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.