Manuel d'utilisation / d'entretien du produit U155B du fabricant Follett
Aller à la page of 24
Manual load unit Model U155, U155X Model U155B, U155BX Model U155R400A/W , U155XR400A/W Model U155BR400A/W , U155BXR400A/W Model U155R800A/W , U155XR800A/W Model U155BR800A/W , U155BXR800A/W A utomati.
.
W elcome to Follett Corporation Important cautions Specifications Installation Installing dispenser in counter Electrical connections Field wiring diagrams Connecting be v erage lines Installing optio.
W elcome to Follett Follett ice dispensers enjoy a well-deserved reputation for excellent performance, long-term reliability and outstanding after-the-sale support. To ensure that this dispenser delivers that same degree of service, we ask that you take a moment to review this manual before beginning the installation of the dispenser.
Specifications Electrical Each icemaker and dispenser require a separate circuit with with electrical disconnect within 10 ft (6m). Equipment ground required. Standard electrical – 115V, 60Hz, 1 phase. Maximum dispenser fuse – 15 amps, Maximum icemaker fuse – 20 amps each.
Dimensions and c learances Required clearances 51" (1295mm) minimum above counter for installation if dispenser will be dropped into counter 36" (915mm) minimum above counter for all units a.
Installation Installing dispenser in counter Note: All dispensers must be supported from below with supplied 6" - 9" (153 – 229mm) adjustable leg accessory, or equivalent. Do not hang dispenser on flange. All dispensers must be installed level in both directions to ensure proper operation.
Electrical connections Model U155, U155X, U155B, U155BX U155R400A/W, U155R400A/WX, U155BR400A/W, U155BR400A/WX U155R800A/W, U155R800A/WX, U155BR800A/W, U155BR800A/WX Electrical connection Hard wiring .
Connecting bevera ge lines 1. Connect syrup and water lines. Non-carbonated water line will be labeled “water”. Syrup lines are numbered and correspond to the valves as shown in drawing(s) below. Valve one is always next to ice tower. 2. Clean and sanitize beverage lines in accordance with cleaning instructions.
Operation How the dispenser w orks Follett’s dispensers are available in automatic load configurations, fed from one or two Follett remote icemakers or manual load configurations (using ice from another source). In all models, ice is stored below the counter in the dispenser storage area.
Cleaning Using solutions below, clean and sanitize storage area and beverage lines before starting unit and on a routine basis as noted below. Note: Always disconnect power before cleaning dispenser.
Recommended daily dispenser cleaning 1. Remove all debris from drain pan. 2. Pour 1 gallon (4L) hot water into drain pan to keep drain lines clear. Recommended weekly dispenser cleaning 1. Remove drain pan and grille and wash with Solution A. Rinse thoroughly.
Service Dispense chute cover removal 1. Remove top cover. 2. Push chute cover up vertically to slip off holding tab. 3. After clearing tab, pull chute cover forward to remove. Auger motor assembly removal 1. Remove top cover. 2. Remove one thumbnut on rear of motor bracket.
14 Wiring diagram 115 VOL TS 24 VOL TS RED - W ARM ST A TUS LIGHTS GREEN - COLD BA TH CONTROL BOARD BEVERAGE COOLING OPTION BLUE BLACK V alve_1 BLACK V alve_6 ICEMAKER #1 V alve_9 V alve_4 YELLOW V al.
If prob lems persist after f ollo wing this basic troub leshooting guide, call Follett’ s technical service department toll at (800) 523-9361 or (888) 2-FOLLETT or (610) 252-7301. Symptom Ice does not dispense. • Auger motor does not run • Wheel motor does not run Ice does not dispense.
16 Condition Pump Solenoids Auger Wheel Beverage valves Top lid off OFF ON OFF OFF ON Rear lid off ON ON OFF OFF ON Drain pan off ON ON OFF OFF OFF On/off switch in off position OFF OFF OFF OFF OFF Be.
Replacement par ts Reference # Description Part # 1 Lid, 8 valve unit (includes “Follett” label) 502436 1 Lid, 10 valve unit (includes “Follett” label) 502437 2 Label, “Follett” 502438 3 C.
Dispense assembly, Side View (RH unit with bath shown) Reference # Description Part # 1 Gate, dispense 502455 2 Linkage pin, gate/solenoid 502456 3 Pin, quick release, 3" (77mm), bath gate and lever 501949 4 Pin, quick release, 5.
Reference # Description Part # 1 Coil, 14" (356mm) riser — carbonated water 00107391 2 Coil, 12-1/2" (318mm) riser — plain water/carbonated water 502461 3 Coil, syrup 502462 4 Pump, wate.
2 Reference # Description Part # 1 Auger, LH unit (black, stamped with “1”) 502491 Not shown Auger, RH unit (gray, stamped with “2”) 502492 2 Tube, auger, LH unit with beverage bath 502486 Not.
Reference # Description Part # Auger motor/drive assembly, vertical (includes all items below) 502493 1 Motor, vertical auger (includes gearbox and capacitor) 502476 2 Chain, auger drive #35, 40p 5024.
Reference # Description Part # 1T ransformer, 24V 502058 2 Relay, auto fill 501826 3 Relay, dispense 501826 4 Timer, auto fill (automatic fill units) 502471 5 Strips, terminal 502472 6 Switches (power.
.
208598R05 02/04 801 Church Lane • PO Box D, Easton, PA 18044, USA Toll free (800) 523-9361 • (888) 2-FOLLETT (610) 252-7301 • Fax (610) 250-0696 • www.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Follett U155B c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Follett U155B - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Follett U155B, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Follett U155B va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Follett U155B, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Follett U155B.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Follett U155B. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Follett U155B ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.