OM48021-1 Rev. C 1 SVR SERIES PRECISION UTILITY VOLTAGE REGULATOR AND CONDITIONER OWNER’S MANUAL SVR1K-1T & SVR2K-2T SVR2K-1T &SVR2K-2T SVR3K-1 & SVR3K-2T FALCON Electric Inc. , 5106 Azusa Canyon Rd., Irwindale, California 91706 800-842-6940 Fax : 626-962-7720 Email: sales@falconups.
OM48021-1 Rev. C 2 SVR SERIES FEATURES • COMPACT SIZE, LIGHT WEIGHT • WIDE INPUT VOLTAGE WINDOW • TIGHT OUTPUT VOLTAGE REGULATION (±2%) • INPUT POWER FACTOR CORRECTION • SURGE PROTECTION .
OM48021-1 Rev. C 3 This following User’s Manual is provided to better enhance your understanding of the product and ensure its proper installation and usage. Reading this manual carefully prior to installation of the SVR Series Precision Utility Voltage Regulator and Conditioner will save ti me and ensure worry-free operation.
OM48021-1 Rev. C 4 CARE & MAINTENANCE The SVR Series Precision Utility Voltage Regulator and C onditioner is designed to be ma intenance-free. It can be cleaned with a damp cloth or nonabrasive cleans er providing it is turned off and t he input plug is disconnected from the utility source.
OM48021-1 Rev. C 5 FRONT PANEL INDICATOR AND FUNCTION KEYS LOAD LEVEL INDICATOR LEDS The first or bottom LED is lit when the output load is greater than 25% of t he rated output of the SVR. The second LED is lit when the output load is gr eater than 50% of the ra ted output of the SVR.
OM48021-1 Rev. C 6 7 FAULT INDICATOR LED This LED is lit during the following conditions: The inverter voltage is too high or low. SVR over temperature condition. Internal DC Bus has an under or over voltage condition. Internal microprocessor or memory failure.
OM48021-1 Rev. C 7 Audiable Alarms Audible alarm signals are divided into two catagories. Each category represents a differ ent level of alarm status. Catagory One Alarms represent normal or correctable operational alarms.
OM48021-1 Rev. C 8 DIP SWITCH SETTINGS (All SVR 1kVA – 3kVA Models) FOR 100-120Vac NOMINAL LINE VOLTAGE SW2 SW1 VOLTAGE Down Down 100V Down Up 110V Up Down 120V Up Up 115V FOR 220-240Vac NOMINAL LIN.
OM48021-1 Rev. C 9 TYPICAL FRONT VIEW INSTALLATION DETAILS SVR1K-1, SVR2K-1, SVR3K-1, SVR1K-2T, SVR2K-2T & SVR3K-2T Tower Models Front Control panel Input Power Circuit Breaker (On the rear panel).
OM48021-1 Rev. C 10 REAR VIEW SVR1 K -2T REAR VIEW SVR2 K -1T & SVR3 K -1T OPTIONAL EXTERNAL BATTERY CONNECTOR OUTPUT RECEPTACLES 4 each IEC 320 COVER PLATE FOR OPTIONAL SNMP AGENT DIP SWITCHES RS.
OM48021-1 Rev. C 11 REAR VIEW SVR2 K -2T & SVR3 K -2T COVER PLATE FOR OPTIONAL SNMP AGENT DIP SWITCHES RS - 232 CONNECTOR COOLING FANS DO NOT BLOCK MAIN POWER SW ITCH & INPUT CIRCUIT BREA KER .
OM48021-1 Rev. C 12 GENERAL PROVISIONS FALCON ® ELECTRIC INC. hereby warrants product shipped under this agreement to be free from defective workmanship for a period of two y ears following date of shipment. This Limited New Product Warranty Agreement only applies to covered repairs to the product occurring w ithin the United States and Canada.
OM48021-1 Rev. C 13 FCC CONSIDERATIONS This equipment generates and uses radio frequency energy and if not installed and us ed properly in strict accordance with the manufacturer’s instructions, may cause interferenc e to radio and television reception.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Falcon OM48021-1 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Falcon OM48021-1 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Falcon OM48021-1, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Falcon OM48021-1 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Falcon OM48021-1, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Falcon OM48021-1.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Falcon OM48021-1. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Falcon OM48021-1 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.