K eep This Manual With Air Conditioner AIR CONDITIONER OPERA T OR'S MANU AL CA UTION BEFORE INST ALLING AND USING THIS AIR CONDITIONER, IT IS IMPORT ANT THA T THIS MANU AL BE READ AND UNDERST OOD THOR OUGHL Y K OOL TRONIC, INC. 30 P ennington-Hopewell Road P ennington, NJ 08534 609 • 466-3400 F AX: 609 • 466-1114 www .
T ABLE OF CONTENTS P age I. Introduction 2 II. Incoming Inspection 3 III. Product Handling 3 IV . Product Identification Label 4 V . Pr inciples of Operation 5 - 6 VI. Pre-Installation T esting 6 VII. Specific Model Data 7 - 10 Mounting Dra wings and Dimensions T echnical Data Major Component Replacements Standard F eatures Wiring Schematic VIII.
3 II. Incoming Inspection K ooltronic Air Conditioners are designed, b uilt and packaged to withstand the shoc k and vibration normally associated with shipment by common carriers.
4 IV . Pr oduct Identification and Labels Each K ooltronic Air Conditioner includes an identification label. This label provides: ➀ Model Number ➁ Serial Number ➂ Electrical power characteristic.
V . Principles of Operation K ooltronic Air Conditioners are required when the equipment operating temper ature must be k ept near or low er than the ambient room temperature, and/or the cabinet m ust be sealed from dust, fumes, oil, corrosiv es and other contaminants.
The heater kit consists of a heater , a heat control ther mostat and a heater limiter . The heater control ther mostat is a bimetal disk with a fix ed set point of 60°F . When the entering e vapor ator air temperature r ises abov e 60°F the heater shuts off, and when the e vapor ator air temperature f alls below 40°F the heater will engage.
VII. Specific Model Data Mounting The K ooltronic Special Pur pose Air Conditioners K_NA4C3P21R hav e been engineered to be installed easily . These units utilize doub le lay er gaskets. The first gasket la yer is placed on the outside perimeter of the front panel that is sealed against the customer enclosure.
8 21.19 [538.2] DRAIN 12.48 [316.9] .36 [9.1] 8.08 [205.2] TYP. 3.40 [86.3] TYP. 9.20 [233.6] TYP. 11.54 [293.1] TYP. 9.20 [233.6] 7.50 [190.5] 1.92 [48.7] 2.00 [50.8] 12.01 [305.0] POWER CORD Drawings and Dimensions K_NA4C3P21R SERIES Dimensions, inches [mm], are f or reference only and are subject to change.
9 T echnical Data KNA4C3P21R 3000 2160 125 0 115 60 11.3 76 K2NA4C3P21R 3000 2160 131 0 230 60 4.7 76 K2NA4C3P21R5 3000 1940 131 0 230 50 4.6 76 * Rating shown is f or operation at maximum ambient temperature . Ambient Ambient Appro ximate BTU/H BTU/H T emp.
10 Wiring Schematic EVAPORATOR FAN CAP. WE GN SUPPRESSOR HEATER THERMAL CUTOUT T-STAT 115 V 230 V TO CUSTOMER ALARM SYSTEM (OPTIONAL) TERMINAL BLOCK COOLING EFFECT DETECTOR BK T-STAT SHORT CYCLE TIMER OPTIONAL SHORT CYCLE PROTECTOR OPTIONAL HEATER SPEED CONTROLLER CONDENSER BLOWER MOTOR CAP.
11 VIII. Maintenance K ooltronic W ater-Cooled Air Conditioners require no maintenance. Air-Cooled Air Conditioners are designed to require only the routine cleaning of air filters to assure unimpeded airflo w through the condenser heat e xchanger .
12 B. Blower s The design lif e of the blowers used in all K ooltronic Air Conditioners is substantially in excess of 20,000 hours. All Kooltronic condenser and e vapor ator blow ers are equipped with automatic-reset ther mal o verload protectors.
. IX. T roub le-Shooting Each K ooltronic Air Conditioner is engineered for perf or mance and b uilt f or reliability . They are designed to require no routine maintenance other than the cleaning of ambient air filters. If your air conditioner should require warr anty ser vice, please contact K ooltronic.
14 This page intentionally left blank.
15 THIS W ARRANTY CONSTITUTES THE ENTIRE W ARRANTY WITH RESPECT T O THE PR ODUCT AND IS IN LIEU OF ALL O THERS, EXPRESSED OR IMPLIED , INCLUDING ANY W ARRANTY OF MERCHANT ABILITY AND W ARRANTY OF FITNESS FOR A P ARTICULAR PURPOSE AND IN NO EVENT IS K OOL TRONIC RESPONSIBLE FOR ANY CONSEQUENTIAL D AMA GES OF ANY NA TURE WHA TSOEVER.
BEAT THE HEAT! KoolTray II - 19” width fan cooling units. Available in 1, 2 and 3 row configurations. Custom/Special units available. Pennington, NJ Ventura, CA Tel: (609) 466-3400 Tel: (805) 642-85.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Event electronic K_NA4C3P21R c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Event electronic K_NA4C3P21R - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Event electronic K_NA4C3P21R, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Event electronic K_NA4C3P21R va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Event electronic K_NA4C3P21R, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Event electronic K_NA4C3P21R.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Event electronic K_NA4C3P21R. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Event electronic K_NA4C3P21R ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.