Manuel d'utilisation / d'entretien du produit TSVFB10LP du fabricant Enerco
Aller à la page of 16
Mr . Hea ter , INC., 4 560 W . 1 60 TH ST ., CLEVELAND, OHIO 4 4 1 3 5 · 2 1 6-9 1 6-3000 W ARNING: If the information in this manual is not followed exactly , a fire or explosion may result causing property damage, personal injur y , or loss of life.
2 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater This appliance may be installed in an aftermarket* permanently manufactured (mobile) home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate.
3 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater DANGER : Carbon monoxide poisoning may lead to death. Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the u, with headaches, dizziness, or nausea.
4 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater b. Whether stripping has been added on openable win - dows and doors, and c.
5 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater attics* and crawl spaces. Follow the National Fuel Gas Code NFP A 54/ ANSI Z223.1, Section 5.3, Air for Com - bustion and V entilation for required size of ventilation grills or ducts.
6 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater W ARNING: A qualied service person must install heater . Follow all local codes. CHECK GAS TYPE Use only LP-gas. If your gas supply is not LP-gas , do not install heater .
7 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater 1. Attach to wall studs 2. Attach to wall anchor Figure 6 Attaching to W all Stud: This way is the best providing the strongest mounting in wood frame houses.
8 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater Figure 10 2. Mark screws locations on wall. 3. Remove heater from mounting bracket. 4. If installing bottom mounting screw into hollow or solid wall, install wall anchors.
9 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater Figure 12 CHECKING GAS CONNECTIONS W ARNING: T est all gas piping and connections for leaks after installing or servicing. Correct all leaks at once. W ARNING: Never use an open ame to check for a gas leak.
10 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater 8. T urn off heater (see T o T urn OFF Gas to Appli- ance , page 10.
11 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater 2. T urn control knob clockwise to the OFF posi - tion. SHUTTING OFF BURNER ONL Y (PILOT ST A YS LIT) 1. T urn control knob clockwise to the PILOT/IGN position.
12 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater TROUBLESHOOTING NOTE: All troubleshooting items are listed in order of operation and likely occurrence. W ARNING: Only a qualied service person should service and repair heater .
13 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater Heater shuts off in use (ODS operates) 1. Not enough fresh air is available 2. Low line pressure 3. ODS/pilot is partially clogged 1. Open window and/or door for ventilation 2.
14 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater UNVENTED LP-GAS FIRED R OOM HEA TER • Model #IR1 0LP/ BF1 0LP Model #IR1 0LP Model #BF1 0LP 19 23 7 8 21 .
15 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater ITEM P ART NO. DESCRIPTION QTY . IR10LP BF10LP 1 70300 70300 Cabinet Assembly 1 1-1 70301 70301 Cabinet T o.
16 Installation Instructions and Owner ’s Manual Unvented Liquid Propane Fired Room Heater Model # Start Serial# MHVFR1 0LP 7 0 54 5000 5 98 1 HSVFR1 0LP 7 0 54 5000 5 98 1 TSVFR1 0LP 7 0 54 5000 5 98 1 MHVFB1 0LP 7 0 5 1 50009 2 69 HSVFB1 0LP 7 0 5 1 50009 2 69 TSVFB1 0LP 7 0 5 1 50009 2 6 9 Mr .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Enerco TSVFB10LP c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Enerco TSVFB10LP - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Enerco TSVFB10LP, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Enerco TSVFB10LP va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Enerco TSVFB10LP, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Enerco TSVFB10LP.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Enerco TSVFB10LP. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Enerco TSVFB10LP ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.