Manuel d'utilisation / d'entretien du produit 430 DO du fabricant Emerson Process Management
Aller à la page of 24
Model 430 DO Dissolv ed Oxygen Sensor Instruction Manual PN 51-430/rev .A May 1996.
CAUTION SENSOR/PROCESS APPLICA TION COMP A TIBILITY The wetted sensor materials may not be compatible with process composition and operating conditions.
MODEL 430 DO T ABLE OF CONTENTS MODEL 430 DISSOL VED OXYGEN T ABLE OF CONTENTS Section Title Page 1.0 DESCRIPTION AND SPECIFICA TIONS ................................................................. 1 1.0 Features and Applications ...................
T ABLE OF CONTENTS CONTINUED LIST OF FIGURES Number Title Page 1-1 Flow Through Senson Assemblies ......................................................................... 2 1-2 Optional Mounting Bracket ...............................................
1 • LARGE ELECTROL YTE RESERVOIR allows up to twelve months and often longer between refills. • OPTIONAL MOUNTING BRACKET allows easy removal of the sensor from an aeration basin without the use of tools. • MODULAR PRESSURE COMPENSA TOR AND MEMBRANE RET AINER simplify recharg- ing and membrane replacement.
2 MODEL 430 DO SECTION 1.0 DESCRIPTION AND SPECIFICA TIONS 1.3 A V AILABLE MODELS The Model 430-01 and -02 Sensor is a flow through assembly . The sensor is supplied in a 1-1/2 inch PVC tee for installation into a process line.
3 MODEL 430 DO SECTION 1.0 DESCRIPTION AND SPECIFICA TIONS FIGURE 1-2 Optional Mounting Bracket DWG. NO. REV . 40043018 B MILLIMETER INCH.
4 MODEL 430 DO SECTION 1.0 DESCRIPTION AND SPECIFICA TIONS 1.5 ORDERING INFORMA TION. The Model 430 Dissolved Oxygen Sensor: Includes PVC body with integral, oxygen-permeable membrane of T eflon 1 . T emperature and pressure compensators included. Compatible with Model1 181DO.
5 MODEL 430 DO SECTION 2.0 INST ALLA TION SECTION 2.0 INST ALLA TION 2.1 GENERAL. This section provides instructions for the Model 430 Dissolved Oxygen Sensor . 2.2 UNP ACKING AND INSPECTION. Inspect the ship- ping container and remove the sensor . Carefully check the sensor and its associated hardware for any dam- age.
6 MODEL 430 DO SECTION 2.0 INST ALLA TION FIGURE 2-1. Codes and 01 and 02 Flow Through Installation DWG. NO. REV . 40043001 G MILLIMETER INCH.
7 MODEL 430 DO SECTION 2.0 INST ALLA TION FIGURE 2-2. Code 03 Sensor Dimensions DWG. NO. REV . 40043002 D MILLIMETER INCH.
.
9 MODEL 430 DO SECTION 3.0 MAINTENANCE SECTION 3.0 MAINTENANCE 3.1 GENERAL. Sensor maintenance consists of keep- ing the sensor clean, recharging the sensor and replacing the membrane.
10 4.1 GENERAL. This section contains troubleshooting data for the Model 430 Sensor Assembly . 4.2 TROUBLESHOOTING THE MODEL 430 DISSOL VED OXYGEN SENSOR.
11 MODEL 430 DO SECTION 5.0 P ARTS LISTS SECTION 5.0 P ARTS LISTS 5.1 GENERAL. This section contains the replacement parts lists and illustrations for the Model 430 Sensor Assembly . Parts are keyed with an item number . Use the illustration to locate the item number for the part in question.
12 MODEL 430 DO SECTION 5.0 P ARTS LISTS Part Number Description Qty . 3002384 Base 1 95501 16 O-ring (2-018)* 1 2002572 Reservoir housing assembly with membrane* 1 3002385 Retainer ,reservoir 1 9550133 O-ring (2-004) 1 3002382 Screw , vent 1 2002473 Recharge Kit 1 FIGURE 5-2.
13 MODEL 430 DO SECTION 5.0 P ARTS LISTS FIGURE 5-3. Model 430 (Code 03) Dissolved Oxygen Sensor DWG. NO. REV . 40043015 A Figure & Part Item No. Number Description Qty .
14 MODEL 430 DO SECTION 5.0 P ARTS LISTS FIGURE 5-4. Model 430 (Code 04) Dissolved Oxygen Sensor DWG. NO. REV . 40043017 A Figure & Part Item No. Number Description Qty .
15 Model 430 DO SECTION 6.0 RETURN OF MA TERIAL SECTION 6.0 RETURN OF MA TERIAL 6.1 GENERAL. T o expedite the repair and return of instruments, proper communication between the cus- tomer and the factory is important. A return material authorization (RMA) number is required.
A Worldwide Network of Sales and Service Emerson Process Management’s field sales of fices are your source for more information on the fill line of Rosemount Analytical products. Field sales personnel will work closely with you to supply technical data and application information.
FROM: RETURN BILL TO: _____________________________ _____________________________ _____________________________ _____________________________ _____________________________ ____________________________.
.
W ARRANTY Seller warrants that the firmware will execute the programming instructions provided by Seller , and that the Goods manufactured or Services provided by Seller will be free from defects in materials or workmanship under normal use and care until the expira- tion of the applicable warranty period.
Credit Cards for U.S. Purchases Only . The right people, the right answers, right now . ON-LINE ORDERING NOW A V AILABLE ON OUR WEB SITE http://www .raihome.com Specifications subject to change without notice. Emerson Process Management Liquid Division 2400 Barranca Parkway Irvine, CA 92606 USA T el: (949) 757-8500 Fax: (949) 474-7250 http://www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Emerson Process Management 430 DO c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Emerson Process Management 430 DO - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Emerson Process Management 430 DO, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Emerson Process Management 430 DO va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Emerson Process Management 430 DO, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Emerson Process Management 430 DO.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Emerson Process Management 430 DO. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Emerson Process Management 430 DO ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.