Installati on Manual Part Number 3-9000-760R evision E March 201 5 Daniel TM 3814 Liquid Ultrasonic Flow Meter.
.
Da n i el c us to m er s er v i ce Email • Custo mer S er vice: tech .ser v ice@em ers onpr ocess .com • Cust omer Support: daniel.cst.support@emerson.c om • Asia -Pacific: danielap .support@ eme rson.com • Eur ope: Dan ielE MA .C ST @E mer son Pro cess .
Sign al w ords and symbols Pay s pecial a tte ntion to the f ollowing signal wor ds, saf ety aler t symbols and state men ts: Impor tant Impor tant is a stat eme nt the u ser needs to know and conside r . Tip Tip provides information or suggestions fo r improved e fficie ncy or best results.
Impor t ant safet y instruc tions Daniel Me asure ment and Control, Inc. (Danie l) designs, manu factures and tests products to func tion within specific conditions.
Product O peration P ersonnel: • T o prev en t person al inj ur y , personnel mu st f ollow al l instructions of this m anual pri or to and during operation of the pro duct. • Follow all warnings, cautions, and notices m arked on, and supplied with, this produc t.
No tic e THE CONTENTS OF THIS PUBLICA TION ARE PRESENTED FOR INFORMA TIONAL PURP OSES ONL Y , AND WHILE E VER Y EFFORT HAS BEEN MAD E T O ENS URE THEIR ACCURACY , THE Y ARE NO T T O BE C ONST RUED AS W A RRANTIES OR GU ARAN TEES , E XPRESSED OR IMPLIED, RE GARDING THE PRODUCTS OR SERVICES DESCRIBED HEREIN OR THEIR USE OR APPLICAB ILIT Y .
W arran t y and Limitations 1. LIMITED W ARRANT Y : Sub ject to the limitati ons co ntained in Section 2 he re in, D anie l Me asure me nt & Control, Inc.
Daniel 3814 Liquid Ultrasonic Meter Installation Manual Table of Contents 3-9000-760 Rev E March 2015 Table of Contents i Co nte nts Preface Danie l cu stomer ser vic e Sign al wor ds and symbols Impor tant saf ety instruc tions Notic e W arranty and Limit ations Section 1: Introduction 1.
ii Table of Contents Table of Contents Daniel 3814 Liquid Ul trasonic Meter In stallation Manual March 2015 3-9000-760 Rev E Section 3: Electrical installation 3.1 Cable length T TL mode ................................................................
Daniel 3814 Liquid Ultrasonic Meter Installation Manual List of Tables 3-9000-760 Rev E March 2015 List of Tables iii List o f T ables T able 1-1 Acronyms, abbreviations and defin itions .................. .............. .............. ........... ...
iv List o f Tables List of Tables Daniel 3814 Liquid Ul trasonic Meter In stal lation Manual March 2015 3-9000-760 Rev E.
Daniel 3814 Liquid Ultrasonic Meter Installation Manual List of Figures 3-9000-760 Rev E March 2015 List of Figures v List o f Figures Figure 1-1 Daniel MeterLink down load and registration ..................... .............. .............. .........
vi List of Figures List of Figures Daniel 3814 Liquid Ul trasonic Meter In stal lation Manual March 2015 3-9000-760 Rev E Figure 4-8 AMS Device Manager - Configure Manual Setup ................. ........... .............. ............... . 74 Figure 4-9 Gating configuration parameter Edge gated, active high .
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Secti on 1: Introduction 3-9000-760 Rev E March 2015 Section 1: Introduction 1 Sec tion 1: In troduc tion Danie l 3814 Liquid Ultra sonic Mete rs hav e variou s conf igurations tha t meet a broad range o f cus tom er req ui rem ents .
2 Typical Applications Section 1: Introduction Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E 1.1 T ypical Applications • Cust ody transf er me a sureme nt • .
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Secti on 1: Introduction 3-9000-760 Rev E March 2015 Features and benefits: 3 1.2 Fe atures and benefits : • Explosion-proof transmitte r e l.
4 Acronyms, abbreviations and definitions Section 1: Introduction Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E 1.
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Secti on 1: Introduction 3-9000-760 Rev E March 2015 Acronyms, abbreviations and definitions 5 m 3 /h cubic mete rs per hour (volume tric flow .
6 Daniel MeterLink software Section 1: Introduction Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E 1.4 Daniel MeterLink sof t w are Danie l Mete rLink TM soft war.
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Secti on 1: Introduction 3-9000-760 Rev E March 2015 Daniel MeterLink software 7 Procedure 1. F rom the right p anel under Quic k Links, c lick the MeterLink R egistration and D ownload link. 2.
8 3814 liquid ultrasonic meter d esign Section 1: Introduction Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E 1.5 3814 liquid ultrasonic meter design The Daniel 3.
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Secti on 1: Introduction 3-9000-760 Rev E March 2015 3814 liquid ultrasonic meter design 9 Figure 1-3 T r ansmitter elec tronics enclosure with.
10 Meter specifications Section 1: Introduction Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E 1.6 M eter specifications Consult your Daniel Sales and Se r vice re presen tative to ensure y ou purchase the c orrec t compone nts and se als f or yo ur application.
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Secti on 1: Introduction 3-9000-760 Rev E March 2015 Meter specifications 11 Body and Flang e Pressure rating ra nge U.
12 Meter specifications Section 1: Introduction Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E Electronic specificatio ns Power Mete r • 10.4 VDC to 36 VDC • 11 W t ypical power consumption Serial cable • Belde n #9940 or equ ivalen t (22 ga uge) – Capacitance (pF/m) 121.
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Secti on 1: Introduction 3-9000-760 Rev E March 2015 Meter specifications 13 Digital, analog, and frequency outputs Fre q ue nc y/ Di g it a l Output(s) The meter h as u ser -configurable selections for eithe r a Freque ncy O utput or Digital status (FODO) (Also see Sectio n 3.
14 Pre-installation considerations Section 1: Introduction Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E 1.7 Pre -installation considerations • Pipeline equipme nt c ode compli ance , AN SI, ASME, etc.
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Secti on 1: Introduction 3-9000-760 Rev E March 2015 Safety 15 Danie l 3810 Serie s Liquid Ultras onic Mete rs are INME TR O ce r tified. R ef e r to the 3810 Se ries Liquid Ultrasonic Flo w Mete r T ag, INME TRO C ertification drawing DMC - 006173.
16 Daniel 3810 Series certifications and approvals Section 1: Introduction Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E 1.
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Secti on 1: Introduction 3-9000-760 Rev E March 2015 FCC compliance 17 Appro val Agenc ies • UL • UL C • DEMK O • INMETRO • NEPSI • GOSTR IMPORT ANT Plea se consult Daniel Cu stomer Ser vice f or the complete metrology approvals list.
18 References Section 1: Introduction Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E 1.11 R eferenc es [1] Goul d Modb us P rotoc ol R ef ere nc e Gui de , R ev .
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 2: Me chanical installation 3-9000-760 Rev E March 2015 Section 2: Mechanical installation 19 Sec tion 2: Mech anical install a tion 2.
20 Meter piping, lifting and mounting Section 2: Mechanical installation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E Consult your Daniel Sales and Se r vice re presen tative to ensure y ou purchase the c orrec t compone nts and se als f or yo ur application.
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 2: Me chanical installation 3-9000-760 Rev E March 2015 Meter components 21 2.2 M eter compo nents Danie l 3810 Serie s Ultrasonic Flow Me ter s are asse mbled, c onfigured, and t ested a t the factor y .
22 Meter components Section 2: Mechanical installation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E Figure 2-1 Daniel 3814 Liquid Ultrasonic Flo w Meter assem.
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 2: Me chanical installation 3-9000-760 Rev E March 2015 Meter components 23 Figure 2-2 T ransmitter electronic s enclosure with optional local d isplay and glass endcap A. B. A. T ransmitter electronics enclosure with glass endca p B.
24 Piping r ecommenda tions Section 2: Mechanical installation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E 2.2.1 Piping recomme nd a tions BURST HAZ ARD Before pipe line cle aning and maint enance (“pi gging operati ons ”), remo ve str aighte ning vanes or fl ow conditi oners.
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 2: Me chanical installation 3-9000-760 Rev E March 2015 Piping recommenda tions 25 Flow conditioning is recommended fo r best measure m.
26 Piping r ecommenda tions Section 2: Mechanical installation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E Figure 2-3 Piping recommendations unidirec tional flow Figure 2-4 Piping recomme ndations bidirectional flow All pipe lengths are minimum: • D = Nominal pipe size in inche s (i.
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 2: Me chanical installation 3-9000-760 Rev E March 2015 Piping recommenda tions 27 Re fe r to the ultra sonic meter product data sheet for piping inf ormation. The Liquid Ultrasonic Flow Mete r D atashee t may be downloaded from the Da niel we bsite : http://www2.
28 High Viscosity piping requirements Section 2: Mechanical installation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E 2.2.2 High Viscosit y piping requireme n ts The piping requirements for High Visc osity meter applications are shown in Figure 2- 5 .
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 2: Me chanical installation 3-9000-760 Rev E March 2015 Meter safety for hoist rings and lifting slings 29 2.
30 Use of appropriate safety engineered sw ivel hoist rings in meter end flanges Section 2: Mechanical installation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E When li f ting a D anie l Ultra soni c Mete r b y itse lf , D anie l rec ommends two meth ods.
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 2: Me chanical installation 3-9000-760 Rev E March 2015 Use of appropriate safety engineered swivel hoist rings in meter end flange s 3.
32 Use of appropriate safety engineered sw ivel hoist rings in meter end flanges Section 2: Mechanical installation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E 8. Always use se parate slings to e ach hoist ring.
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 2: Me chanical installation 3-9000-760 Rev E March 2015 Use of appropriate safety engineered swivel hoist rings in meter end flange s 33 9. NEVER allow the slings to c ontact the electronic s enc losure .
34 Use of appropriate safety engineered sw ivel hoist rings in meter end flanges Section 2: Mechanical installation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E prior to be plac ed in any fur ther service. If a prope r inspection cannot be performed, discard the hoist ring.
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 2: Me chanical installation 3-9000-760 Rev E March 2015 Use of appropriate safety engineered swivel hoist rings in meter end flange s 3.
36 Appropriately rated lifting slings Section 2: Mechanical installation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E 2.
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 2: Me chanical installation 3-9000-760 Rev E March 2015 Appropriately rated lifting slings 37 6. NEVER all ow the slings t o contact the elec tronics enclosure or the transducer cabling.
38 Mounting requirements in heated or cooled pipelines Section 2: Mechanical installation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E 2.4 Mounting requirements in heated or c ooled pipelines The ambien t oper ating te mpe rature o f the Danie l 3814 Liquid Ultra sonic Flow Met er electronics (i.
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 3: El ectrical installation 3-9000-760 Rev E March 2015 Section 3: Electrical installati on 39 Sec tion 3: Elec trical inst all a tion 3.1 Cable length T TL mode The maximum cable leng th is 2000 feet whe n the “T TL” mode is se lec ted.
40 Grounding meter electronics Section 3: Electrical instal lation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E 3.3 Grounding meter electronics Daniel Liquid Ultra sonic Flow Meter e lect ronics should be internally grounded for intrinsically saf e ope rations.
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 3: El ectrical installation 3-9000-760 Rev E March 2015 Conduit seals 41 Figure 3-2 External gro und lug 3.4 Conduit seals Danie l 3814 Liquid Ultra sonic Mete rs require conduit seals f or installations in h azardou s en vironme nts.
42 Startup for systems using explosion-proof conduit Section 3: Electrical instal lation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E 3.4.1 S tar tup for syste ms u sing explosion-proof c onduit 1. Assemble conduit to the T ransmi tte r Electro nics Enclosure .
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 3: El ectrical installation 3-9000-760 Rev E March 2015 Startup for systems that use flame-proof cable 43 3.4.2 S tar tup for syste ms th at u se fl ame-proof cable 1. Check to m ake ce r tain that all fie ld wiring powe r is turned OFF .
44 Wiring and I/O Section 3: Electrical instal lation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E 3.5 Wiring and I/O Daniel Met erLink u ses the T CP/IP protoc ol to communica te with the 960-24™ M STS electronic s inste ad of Modbus ASCII or RTU .
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 3: El ectrical installation 3-9000-760 Rev E March 2015 CPU Module labeling and LED indicators 45 3.
46 CPU Module labeling and LED indicat ors Section 3: Electrical instal lation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E T a ble 3-2 CPU Module labeling and LED functions CPU Module swit ch Fu n c t io n Switch position indicator or LED WRITE PRO T .
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 3: El ectrical installation 3-9000-760 Rev E March 2015 CPU Module labeling and LED indicators 47 Ethernet comm unications The Ethe rne t port IP addr es s, subn et m a sk, and g a tewa y ad dre ss are so f tware-con fig urable .
48 CPU Module labeling and LED indicat ors Section 3: Electrical instal lation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E A DIN 41612 48-pi n conn ector is the in te r fac e from the CPU Module t o the Fie ld Co nnection Board (m ale end loca ted on the back of the Fie ld Connection Board).
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 3: El ectrical installation 3-9000-760 Rev E March 2015 CPU Module labeling and LED indicators 49 Figure 3-4 PC to mete r serial connec.
50 I/O connections Section 3: Electrical instal lation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E 3.6 I/O connec tions The 960-24™ MSTS provi des I/O connections on the CPU Module . Figure 3-5 CPU Module I/O connections A.
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 3: El ectrical installation 3-9000-760 Rev E March 2015 Frequency/Digital outputs 51 3.6.1 F reque nc y/Digital outputs The meter h as three use r -c onfigurable selections for configuring eithe r a Freque nc y output or Digital output (FODO).
52 Frequ ency/Di gital o utputs Section 3: Electrical instal lation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E F requency or Digital Outputs (FODO 3) sou rc.
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 3: El ectrical installation 3-9000-760 Rev E March 2015 Frequency/Digital outputs 53 Output for FODO1 and Digital Output1 (Group 1 o n the CPU Module) share a common ground and hav e 50V isolation.
54 Analog input settings Section 3: Electrical instal lation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E 3.6.2 Analog inp ut se tting s The 960-24™ MSTS has the capability to samp le analog te mpera ture (Analog Input 1) and pressure (An alog Input 2) with 4-20 mA signals.
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 3: El ectrical installation 3-9000-760 Rev E March 2015 Configuration protect switch settings 55 3.6.6 Con figura tion pro tect switch se tting s The mete r’s conf iguration parame te rs and fir mwar e can be protected against ch anges vi a CPU Module Write PR O T .
56 Securing the meter Section 3: Electrical instal lation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E 3.6.8 Securing the met e r Securit y se als protect the integrit y of the mete r metrology and pre ven t tampering with transduce r as semblie s.
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 3: El ectrical installation 3-9000-760 Rev E March 2015 Securing the meter 57 2. Install the security seal wire into and th rough one o f the t wo holes in the end cap .
58 Securing the meter Section 3: Electrical instal lation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E Base Enclosure Secu rit y Seals Use the following instructions to in stall the securit y seal wire on the Base Enclosure.
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 3: El ectrical installation 3-9000-760 Rev E March 2015 Securing the meter 59 3. Feed the security wire bene ath the T ransm itte r Electronic s Enclosure and through the adjac e nt sock et he ad screw .
60 Securing the meter Section 3: Electrical instal lation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E T ransducer assembly security seal Use t he fo llowing i nstructions and Figure 3-12 to install the securit y seal wire on the transdu ce r asse mbly .
Daniel 3814 Liquid Ultrasonic Meter Installati on Manual Section 3: El ectrical installation 3-9000-760 Rev E March 2015 Sealing the unit 61 3.6.9 Sea ling the unit The unit should be prope rly se aled with a se al ing compound af te r electr ical connections have been te sted acc ording t o the cu stome r's Best Practices schedule .
62 Sealing the unit Section 3: Electrical instal lation Daniel 3814 Liquid Ultrasoni c Mete r Installation Manual March 2015 3-9000-76 0 Rev E.
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Section 4: Configuration 3-9000-760 Rev E March 2015 Section 4: Configuration 63 Sec tion 4: Con figuration Af te r the mechanical and elec tri.
64 Field Setup Wizard Section 4: Configuration Daniel 3814 Liquid Ul trasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E 4. Con figure F requency output 1 and F reque ncy output 2 c onte n.
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Section 4: Configuration 3-9000-760 Rev E March 2015 Field Setup Wizard 65 Display It ems The valid l abels, de scrip tions and units f or the .
66 Field Setup Wizard Section 4: Configuration Daniel 3814 Liquid Ul trasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E Note : When conn ec ted to a meter wit h th e local display option, reve rse flow direc tion is indicated with a minus sign (negative) bef ore the value(s) shown on the displa y .
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Section 4: Configuration 3-9000-760 Rev E March 2015 Field Setup Wizard 67 Display units The Meter volume unit s display ed are either U.S. Customar y or Metric. T o modif y the Display Units, c onfi gure the Me te r units syst em in th e Fiel d Setup Wi zard — Ge ne ral Pa ge .
68 Using AMS Device Manager to configure the meter Section 4: Configuration Daniel 3814 Liquid Ul trasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E 4.
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Section 4: Configuration 3-9000-760 Rev E March 2015 Using AMS Device Manager to configure the meter 69 10. C lick the Daniel Industries Liquid 3810 Series Rev 1 hyperlink. The file downlo ad dialog displa ys.
70 Using AMS Device Manager to configure the meter Section 4: Configuration Daniel 3814 Liquid Ul trasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E 17. C lick the Co nfig ure tab , and the n se lect Guided Setup , Manual Setup or Alert Setup .
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Section 4: Configuration 3-9000-760 Rev E March 2015 Using AMS Device Manager to configure the meter 71 AMS Devic e Manager - Guided Setup The Guided setup wizard pro vides con figuratio n paramete r settings f or the mete r .
72 Using AMS Device Manager to configure the meter Section 4: Configuration Daniel 3814 Liquid Ul trasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E 4. Af ter a ll of the dat a sh own belo w is entere d, clic k Apply to wr ite th e param eters to the mete r .
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Section 4: Configuration 3-9000-760 Rev E March 2015 Using AMS Device Manager to configure the meter 73 d. Click the All V ariables t ab to view a g raphical display of the Pr imar y , Secondar y , Third and Fo ur th V ariables.
74 Using AMS Device Manager to configure the meter Section 4: Configuration Daniel 3814 Liquid Ul trasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E AMS Device Manager - Manual Setup Use t he Manual Setup wizard to confi gure t he m eter’s pa rameter s.
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Section 4: Configuration 3-9000-760 Rev E March 2015 Using AMS Device Manager to configure the meter 75 6. Click the Frequency/Digit al Outputs tab. Follow the con figuration instruc tions in the AMS De vice M anage r - Guided Se tup , Step 3 a.
76 Using AMS Device Manager to configure the meter Section 4: Configuration Daniel 3814 Liquid Ul trasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E b .
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Section 4: Configuration 3-9000-760 Rev E March 2015 Using AMS Device Manager to configure the meter 77 12. C lick the Alert Setup ta b (from the main Configuration page). Figure 4-13 Configure F low Analysis Aler t 13.
78 Using AMS Device Manager to configure the meter Section 4: Configuration Daniel 3814 Liquid Ul trasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E 14. Click the Service T ools tab to acces s the devic e alerts, variables, tr ends and ma inte nanc e statuses or to edit the configuration paramet ers.
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Section 4: Configuration 3-9000-760 Rev E March 2015 Using AMS Device Manager to configure the meter 79 c. Cli ck the Ser vice T ools|V ariables tab. The V ar iables page displays tabs for the device’s Flow D ata, Path Informa tion, Flow T otals, and All V ariables).
80 Using AMS Device Manager to configure the meter Section 4: Configuration Daniel 3814 Liquid Ul trasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E g. Click Ser vice T ools|V ariables|All V ariables tab t o view Primar y , Se cond ar y , Third and Fo ur th V ariable para met er stat us.
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Section 4: Configuration 3-9000-760 Rev E March 2015 Using AMS Device Manager to configure the meter 81 h. Click the Ser vice T ools|T rends tab to displa y the device vari ables (uncorrected volume flow ra te , pressure and t empe rature) trends.
82 Using a Field Communicator to c onfigure the meter Section 4: Configuration Daniel 3814 Liquid Ul trasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E 4.
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Section 4: Configuration 3-9000-760 Rev E March 2015 Using a Field Communicator to conf igure the meter 83 Procedure 1. R emov e electrical power to the mete r . If i nstalled, remov e the endcap securit y latches and seals and the n, remo ve the e ndcap .
84 Using a Field Communicator to c onfigure the meter Section 4: Configuration Daniel 3814 Liquid Ul trasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E 5. Wire Anal og Input 1 (AI1) and An alog Output 1 (A O1) a s shown in Fi gure 4-20 and Appendix A , drawing DMC -005324.
Daniel 3814 Liquid Ultrasonic Meter Inst allation Manual Section 4: Configuration 3-9000-760 Rev E March 2015 Security seals for the meter (optional) 85 4.
86 Security seals for the meter (optional) Section 4: Configuration Daniel 3814 Liquid Ul trasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E.
Daniel 3814 Liquid Ul trasonic Meter Installation Manual E ngineering drawings 3-9000-760 Rev E March 2015 Daniel 3810 Series Liquid Ultrasonic Flow Meter dra wings 87 APPENDIX APAGE 498 Appe ndix A: Enginee r ing dra wing s A .
88 Daniel 3810 Series Liquid Ultrasonic Flow Meter drawings Engineering drawings Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-76 0 Rev E.
.
.
.
.
Daniel 3814 Liquid Ultrasonic Meter In stallation Manual Open source licenses 3-9000-760 Rev E March 2015 89 A Appe ndix B: Ope n sourc e lic e nses Sourc e code f or ex ecutable file s or librarie s inclu ded in this product is provided pe r the indicat ed lice nse in the table be lo w .
90 GNU General Public License Open source licenses Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-760 Rev E Follo w the link be low t o the Danie l® Liqui d Ultra sonic Products GPL we bpage f or additi onal open sourc e info rmation and zipped source c ode files.
Daniel 3814 Liquid Ultrasonic Meter In stallation Manual Open source licenses 3-9000-760 Rev E March 2015 GNU General Public License 91 The GNU General Public License (GPL) Version 2, June 1991 Copyright (C) 1 989, 1991 Free Softwar e Foundation, Inc.
92 GNU General Public License Open source licenses Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-760 Rev E For example, if you distribute copies of such a program, whether gratis o r f o r a f e e , y o u m u s t g i v e t h e recipients all the rights that you have.
Daniel 3814 Liquid Ultrasonic Meter In stallation Manual Open source licenses 3-9000-760 Rev E March 2015 GNU General Public License 93 TERMS AND CONDITIONS FO R COPYING, DISTRI BUTION AND MODIFICATIO N 0 .
94 GNU General Public License Open source licenses Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-760 Rev E 2 . You may modify your copy or copie s of the Progra m or any po.
Daniel 3814 Liquid Ultrasonic Meter In stallation Manual Open source licenses 3-9000-760 Rev E March 2015 GNU General Public License 95 In addition, mere aggregation of another work not based on the P.
96 GNU General Public License Open source licenses Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-760 Rev E If distribution of executab le or object code i s made by offeri .
Daniel 3814 Liquid Ultrasonic Meter In stallation Manual Open source licenses 3-9000-760 Rev E March 2015 GNU General Public License 97 Program by all those who rec eive copies directly or indirectly throu gh you, then the only way you could satisfy both it and this Lice nse would be to refrain entirely from dis t ribution of the Program.
98 GNU General Public License Open source licenses Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-760 Rev E conditions either of tha t version or of any later version p ublished by the Free Software Found ation.
Daniel 3814 Liquid Ultrasonic Meter In stallation Manual Open source licenses 3-9000-760 Rev E March 2015 GNU General Public License 99 How to Apply These Terms to Your New Programs If you develop a n.
100 GNU General Public License Open source licenses Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-760 Rev E The hypothetical commands `show w' and `show c' sh ould show the appropriate parts of the General Public License.
Daniel 3814 Liquid Ultrasonic Meter In stallation Manual Open source licenses 3-9000-760 Rev E March 2015 GNU Lesser General Public License 101 B.2 G NU Lesser General Public Lic ense GNU LESSE R GENERAL PUBLIC LIC ENSE V ersi on 3, 29 June 2007 Copyright © 2007 Free Softwa re Foundat ion, Inc.
102 GNU Lesser General Public License Open source licenses Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-760 Rev E The "Corresponding Application Code" for a Co m.
Daniel 3814 Liquid Ultrasonic Meter In stallation Manual Open source licenses 3-9000-760 Rev E March 2015 GNU Lesser General Public License 103 4. Combined W o rks.
104 GNU Lesser General Public License Open source licenses Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-760 Rev E 5. Combined Libr aries.
Daniel 3814 Liquid Ultrasonic Meter In stallation Manual Open source licenses 3-9000-760 Rev E March 2015 BSD Open Source License 105 B.3 BSD Ope n Source Lic ense For mor e details abou t the Ope n Sourc e TM BSD li ce nse or t he Open Sour ce In itia tive , f ollow the link be low: http://www .
106 M.I.T License Open source licenses Daniel 3814 Liquid Ultrasonic Meter Installation Manual March 2015 3-9000-760 Rev E B.4 M. I.T L ic e nse For mor e details abo ut the Ope n Sourc e TM MIT license or the Open Source Initia tive follow the link below: http://www .
Daniel 3814 Liquid Ultrasonic Meter Installation Manual Index 3-9000-760 Rev E March 2015 Manual index 107 Appe ndix C: Index C. 1 M a n u a l in d e x A Acronyms, abbreviati ons and definitions ......... ........ ........ 4 American Dr ill Bushing Company .
108 Manual index Index Daniel 3814 Liquid Ultrason ic Meter Instal lation Manual March 2015 3-9000-76 0 Rev E Meter specifications .. ........... .......... .......... .......... ........... ........ 10 Accuracy Limits .................. .......... ..
.
P/N 3-9000-760 Rev E 2015 Daniel Measuremen t and Control, Inc . 11100 Brittmoore Park Drive Houston, TX 77041 USA T+1 713-467-6000 F+1 713-827-4805 USA Toll Free 1 888-356-9001 Daniel Measuremen t Services, Inc. T +1 713-827-6314 www.Daniel.com This product is a core c omponent of the P lantWeb digital plant archi tecture.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Emerson Process Management 3-9000-760 Revision E c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Emerson Process Management 3-9000-760 Revision E - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Emerson Process Management 3-9000-760 Revision E, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Emerson Process Management 3-9000-760 Revision E va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Emerson Process Management 3-9000-760 Revision E, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Emerson Process Management 3-9000-760 Revision E.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Emerson Process Management 3-9000-760 Revision E. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Emerson Process Management 3-9000-760 Revision E ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.