Part No. F40BP73550001 Form No. BP7355-1 U.L. Model No.: CF100 READ AND SA VE THESE INSTRUCTIONS Net Weight: 30.0 Lbs. PERISTYLE ™ Ceiling Fan Owner's Manual Model Number s CF100AP00 Antique P .
W ARNING: T o avoid fire, shock, and serious personal injury , follow these instructions. Safety Instructions 1. Read your owner ’s manual carefully and keep it for future reference.
T ools Needed for Assembly One Phillips head screwdriver One wire stripper One stepladder Three 60-watt (max.) candelabra base bulbs Six wire connectors (supplied) Materials Wiring, outlet box and box connectors must be of type required by the local code.
Preset Memory Feature Y our remote control receiver is equipped with a preset memory feature. The receiv- er will remember the light intensity and fan speed when the light and fan are turned off from the wall switch. When the wall switch is turned back on, the lights and fan will resume operation as they were prior to the switch being turned off.
2. Slide the four switch levers on the code switch to your choice of ON (up) or down positions. Use a ball-point pen or small screwdriver and slide the levers firmly up or down. 3. In the receiver (Figure 1), slide the four switch levers to the same positions as set in the transmitter .
5. Reinstall the hanger ball (Figure 5) on the downrod as follows. Route the three 80” motor leads through the hanger ball and slide the hanger ball over the downrod. Position the pin through the two holes in the downrod and align the hanger ball so the pin is captured in the groove in the top of the hanger ball.
11 . Engage the connector of the switch housing/light fitter assembly with the motor connector (Figure 8). The two connectors are color-coded and must be mated correctly (color-to-color) before they can be engaged. Make sure the connectors close properly .
2. Carefully lift the fan and seat the hang- er ball/downrod assembly on the hang- er bracket that was just attached to the outlet box (Figure 12). Be sure the groove in the ball is lined up with the tab on the hanger bracket (Figure 1 1).
9 1. Position the supply wires to the left side of the outlet box (Figure 13); position the fan wires to the right side. Partially insert the remote control receiver (flat side up) until one end rests on the hanger ball as shown in Figure 13. NOTE: Make all wiring connections using wire connectors (supplied).
7. Screw three 60-watt (maximum) cande- labra base bulbs into the light fitter sockets (Figure 16). 8. Place the lower glass in the lower ring assembly (Figure 16).
NOTE: Slightly loosen the four screws securing the lower ring brackets to the switch housing assembly . 9. Securely grasp one of the lower ring posts and raise the lower ring up to one of the lower ring brackets. Secure the lower ring post to the lower ring brack- et using a bracket mounting screw (Figure 16).
12 Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. ! W ARNING The use of any other control not specifically approved for this fan could result in fire, shock and per- sonal injury .
13 T rouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not 1. Fuse or circuit breaker 1. Check main and branch start. blown. circuit fuses or circuit breakers. 2. Loose power line 2. Check line power connections connections to the fan, or to fan and wire.
14 Repair Parts 16 17 3 2 1 5 4 7 6 14 18 19 15 23 25 24 22 21 9 8 11 10 12 13 26 FAN/OFF FOR/REV LIGHT DIMMER HI MED LOW ® 20 U.L. Model No.: CF100 BP7355 PERISTYLE CF100 9/19/07 11:26 AM Page 14.
Part Numbers Key Model No. Model No. Model No. N o . Description CF100AP00 CF100DBK00 CF100GES00 * Hanger Pack, Consisting of: 761655-34 761655-36 761655-35 1 Bracket, Hanger Assembly (1) — — — .
LIMITED WARRANTY What The War ranty Covers: This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials. Y ou must be the original purchaser or user of the product to be covered.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Emerson CF100DBK00 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Emerson CF100DBK00 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Emerson CF100DBK00, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Emerson CF100DBK00 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Emerson CF100DBK00, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Emerson CF100DBK00.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Emerson CF100DBK00. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Emerson CF100DBK00 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.