UST Universal Slim Twin Model Number 16C26S-010 OWNERS MANUAL • Installation • Operation • Basic UST Service Guide • T echnical Repair Guide • Repair Parts Part No. 37-6070A Replaces 846-2027 Rev B 0015 Electronic Air Cleaner Printed In U.S.
2 RULES FOR SAFE INST ALLA TION AND OPERA TION Please read instructions before installing and using the Electronic Air Cleaner. This will help you obtain the full benefit from the Electronic Air Cleaner you have selected. WARNING ! ELECTROCUTION HAZARD Shut off power at fuse panel before servicing.
3 HOW THE AIR CLEANER WORKS Dirt particles flowing through the ducts (Figure 1) first enters the pre-filters (A) where large particles (hair, lint, etc.) are trapped. Smaller particles (smoke, dust, pollen, etc.) pass through these pre-filters and enter the ionizing section (B).
4 PREINST ALLA TION facing the power door. Air flow direction must agree with arrow embossed on end of collecting cells. After installing the cell sections, install pre-filters in cabi- net tracks on the right. This will again place the pre-filters on the air entering side (on the same side as ionizing wires).
5 TYPICAL MOUNTING POSITIONS BASEMENT FURNACE (LOWBOY) (Figure 6) Cleaner is mounted hori- zontally in return plenum, just above furnace. COUNTERFLOW FURNACE (Figure 7) Cleaner is mounted horizon- tally in return duct or plenum, just above furnace. HIGHBOY FURNACE (Figure 8) Side installation.
6 INST ALLA TION REMOVE OLD FILTER AND DISCARD (Figure 12) NOTE: This filter may be mounted in the furnace compart- ment. CLEAN BLOWER COMPARTMENT It is suggested that the furnace blower compartment, blower and blower housing be cleaned to ensure clean air circulation.
7 WIRING INSTRUCTIONS 7. With the cabinet installed, the air cleaner can now be wired to electrical input source. WARNING ! Installation of this unit must comply with local electric codes or other applicable codes. Review and understand local codes prior to in- stallation.
8 An alternate method for controlling the air cleaner operation is to install an F859-0381 Air Flow Switch/ Harness Kit (available separately) that switches power to the air cleaner when airflow is detected. NOTE: The air cleaner should not be operating un- less the furnace blower is on.
9 3. Release the latch on top of power pack and pull the power pack straight away from cabinet at the top. Then lift pack out of ledge at bottom edge of cabinet. Set power pack aside. 4. Remove the cell(s) and pre-filter(s) from cabinet. Using a solution of warm water and low sudsing detergent, soak cell(s) and pre-filter(s) for 20 to 30 minutes.
10 SERVICE INDICA TION SER VICE CHECKS ON/OFF switch “ON” Unit functioning Normally Blower ON Operating Light ON ON/OFF switch “ON” 1. Power is not being supplied to air cleaner . Blower ON A. Check fuse or circuit breaker . Operating Light OFF B.
11 TECHNICAL REP AIR GUIDE All voltage measurements indicated can be made with a high voltage D.C. probe and a general purpose volt ohm meter. For example: Simpson 260 or equivalent. NOTE: All tests to be performed with the Ozone Reduc- tion Jumper intact.
12 POWER SUPPLY CHECKOUT PROCEDURE 1. Turn power switch to the “OFF” position and remove the power pack from cabinet. 2. Place power pack on a well insulated workbench. Connect meter negative (-) lead to the sheet metal chassis and the high voltage probe to high voltage contact on back cover of power pack.
13 NOTES.
14 REP AIR P AR TS.
15 ITEM NO. DESCRIPTION P ART NUMBER 16C28S-010 1 Cabinet N/A 2 Pre-Filter • F825-0337 3 Collecting Cell • F81 1-0321 4 Junction Box Cover F838-0072 5 * Screw #6 x 3/8 ------ 6 Connector , Female .
White-Rodgers Division, Emerson Electric Co. 9797 Reavis Road, St. Louis, MO 63 123-5398 314-577-1300 • FAX 314-577-1517 www.white-rodgers.com Controlling America’s Indoor Comfort NOTICE T O CONSU.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Emerson 16C26S-010 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Emerson 16C26S-010 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Emerson 16C26S-010, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Emerson 16C26S-010 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Emerson 16C26S-010, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Emerson 16C26S-010.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Emerson 16C26S-010. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Emerson 16C26S-010 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.