Manuel d'utilisation / d'entretien du produit CXA160 / CXA80 du fabricant EAW
Aller à la page of 16
CX A 160 / CX A 8 0 Integrated Amplifiers INSTRUCTION MANUAL.
2 – CXA160 / CXA80 1. SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not use this apparatus near water . 6. Clean only with a dry cloth. 7. Do not block any ventilation openings.
CXA160 / CXA80 – 3 2. INTRODUCTION The CXA160 and CXA80 amplifiers are designed for continuous duty in speech, music, paging and sound reinforcement applications in churches, schools, offices, are.
4 – CXA160 / CXA80 3. FRONT P ANEL FEA TURES 1. EQ-LOW T urn this clockwise to boost the level of the low-frequency range below 100 Hz. T urn it counter -clockwise to cut the level. In the detented center position, there is no change in level. The maximum boost and cut is 12 dB.
CXA160 / CXA80 – 5 4. REAR P ANEL FEA TURES INPUT CONNECTORS The Input section has four different styles of input connections for line-level audio signals. Choose one which suits your system the best: 6. Combination XLR/TRS connector . This can accept a male balanced XLR connector , a balanced TRS or unbalanced TS 1/4" connector .
6 – CXA160 / CXA80 PRIORITY CONNECTORS When a signal above –20 dB is detected at the priority input, the main input is muted. This is useful for making announcements, as the music program is then automatically muted.
CXA160 / CXA80 – 7 P ARALLEL OUTPUT CONNECTORS These outputs allow you to send a copy of the input signals to another amplifier or component in your system. The output is not affected by the volume or EQ controls. There will only be an output here if the Input DIP switch Pin 1 is set in the UP position (see page 5 for details).
8 – CXA160 / CXA80 24. Output Connectors This is a five-position barrier strip for connection of speaker loads. Each terminal accepts bare wire from 22 AWG to 10 AWG, or spade lugs sized for the same range of conductors. T erminals are provided for 4 ohm low-impedance loads or 25, 70 and 100 V olt high-impedance loads.
CXA160 / CXA80 – 9 GND and 100V are used to connect 100V speakers Use Class II wiring: 25. AC Power The CXA160 and CXA80 are fitted with a detachable IEC socket for AC input. Each unit is fitted with a universal power supply , allowing it to operate from any AC mains supply from 100 to 240 V AC, 50-60 Hz.
10 – CXA160 / CXA80 5. THERMAL CONSIDERA TIONS The power amplifier within the unit is convection cooled rather than fan cooled. Heat is drawn away from the amplifier by the heatsink and radiated through the cooling vents in the top and bottom cover .
CXA160 / CXA80 – 11 7. TYPICAL HOOKUP DIAGRAM A M/ FM T un er o r C D P la ye r P ag i n g Mi c ro ph o n e L in e- l e v e l o ut p u t t o t he i n p u t of a no th e r C XA 16 0 ( f o r ex a m pl.
12 – CXA160 / CXA80 8. SPECIFICA TIONS Audio Input and Proximity input Input T ype Balanced Differential, Unbalanced Input Impedance 30 k Ω (Bal, Line-In) 2.
CXA160 / CXA80 – 13 BLOCK DIAGRAM DIP 1 DIP 2 DIP 3 DIP 4 DIP 5 XLR/TRS Combo Screw T erminal External Priority Switch (option) Phoenix Connector Mic/ Line Mic/ Line 24V Phantom High Pass Pad Enable.
14 – CXA160 / CXA80 9. SERVICE INFORMA TION In the event that your CXA160 or CXA80 should require servicing, please follow these instructions: 1. Call EAW Commercial T ech Support at 1-888-337-7404, 7 am to 5 pm PST (Monday-Friday), to verify the problem and obtain a Return Authorization (RA) Number .
CXA160 / CXA80 – 15 10. EA W COMMERCIAL W ARRANTY Warranty : LOUD T echnologies Inc. requires its authorized EAW Commercial distributors to abide by the following warranty terms for all EAW Commerci.
EA W Commercial A LOUD T echnologies Inc. Company EAW Commercial | One Main Street | Whitinsville, MA 01588 USA | TEL toll free within US/Canada 888.337.7404 TEL outside US 425.892.6503 | FAX 425.485.1152 | www .eawcommercial.com © 2007 LOUD T echnologies Inc.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté EAW CXA160 / CXA80 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du EAW CXA160 / CXA80 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation EAW CXA160 / CXA80, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le EAW CXA160 / CXA80 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le EAW CXA160 / CXA80, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du EAW CXA160 / CXA80.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le EAW CXA160 / CXA80. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei EAW CXA160 / CXA80 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.