T ype C40 / 1 10 822 6100 - 52 T .B. 09/2005 ABSORPTION - REFRIGERA T OR for CARA V AN and MOT ORHOME AUS English RM 7271 L RM 7275 L RM 7291 L RM 7295 L RM 7361 L RM 7365 L RM 7371 L RM 7401 L RM 7405 L Model number ..................................
2 www .dometic.com Instructions for storing food in a refrigerator: No refrigerator of any kind can improve the quality of the food; refrigerators can only maintain the food's quality for a short duration as from the time of storing it.
3 1.0 INTRODUCTION 4 2.0 FOR YOUR SAFETY 4 2.1 W arning and safety notices 4 2.2 Coolant 4 3.0 W ARRANTY AND CUST OMER 5 SER VICE 3.1 Damage in transit 5 4.0 DESCRIPTION OF MODEL 5 5.0 REFRIGERA T OR GUIDE 5 5.1 Cleaning 5 5.2 Using the refrigerator 6 5.
4 INTRODUCTION Y ou have made an excellent choice in selecting the Dometic Absorption Refrigerator . We are sure that you will be fully satisfied with your new appliance in all respect s.
5 W ARRANTY AND CUST OMER SER VICE W arranty arrangement s are in accordance with the normal conditions applicable for the country concerned. For warranty or other servi cing, please contact our Dometic Service dep artment. Any damage due to improper use is not covered by the warranty .
6 Using the refrigerator The cooling unit is silent in operation. When the appliance is first put into operation, there may be a mild odour which will disappear after a few hours.
7 Proceed to the description that applies to YOUR model. Electrical operation 1. 12V - operation (DC) The refrigerator should only be used while the motor is running, otherwise the on-board-battery would be discharged within a few hours! 2.
8 Gas operation The refrigerator should only be operated using liquid gas (prop ane). Do not use Autogas, town gas or natural gas. If the refrigerator is operated during travel using gas, the precautions stipulated by the legislation in the respective country must be t aken .
“AUT O”-operation RM7XX5 L - models are equipped with an “AUTO”-MA TIC function. Explanations: Upon switching on, the electronics automatically select one of the three possible energy types: 230V - 12V - liquid gas .
Additional functions ( RM 7XX5 L - models only ) T emperature setting cooling comp artment As shown, you are able to regulate the temperature of the cooling compartment, if necessary , by turning rotary knob (B) . 10 5.2.6 5.2.7 B T T I I P P medium setting The cooling unit’s performance is influenced by ambient temperatures.
11 Making ice cubes Ice cubes are best frozen overnight. At night, the refrigerator has less work to do and the unit has more reserves. Defrosting As time goes by , frost builds up on the fins. When the layer of frost is about 3mm thick, the refrigerator should be defrosted.
12 Door locking Switching off Winter operation 1. Check that the ventilation grills and the extractor have not been blocked by snow , leaves or similar . 5.8 2. When the ambient temperature falls below 46°F , the optional winter covers should be fitted.
13 Interior light Changing the light bulbs Changing the decor p anel Dimensions of the p anels in mm: Model Height Wid th Thickness RM 7271 /..75 730+1 453,5+1 3,2 RM 7361 /..65 730+1 453,5+1 3,2 RM 7371 713+/-1 453,5+1 3,2 RM 7291 /..95 730+1 491,5+1 3,2 RM 7401 /.
14 Changing the doorhang 5.12 It is not always possible to change the door when the refrigerator is installed. 1. Open the door , unscrew the hinge screw and keep it to hand. 2. T ake off the door by moving it upwards. 5 . Attach the door . 8 . Screw the hinge screw back in.
15 T roubleshooting 5.13 Failure : The refrigerator does not work in gas operation mode. Possible cause Action you can take a.) Gas bottle empty . b.) Is the supply cut-out device open? c.) Air in the gas pipe? Before calling the authorised Service Department, please check whether: 1.
16 Maintenance Works on gas component s and electical installation may only be carried out by authorised personnel. We recommend to cont act your Dometic Service Centre. The appliance´s gas equipment and it’s associated fume system must be inspected after inst allation.
17 T echnical dat a We reserve the right to make technical changes. *Average consumption measured at an average ambient temperature of 25°C in pursuance of ISO S tandard. Connecting point s 5.19 RM 7271(L) 821x486x541 77 lit. 9.5 lit. 125 W / 120 W ca.
18 INST ALLA TION GUIDE On installation of the appliance, the technical and administrative regulations of the country in which the vehicle will first be used must be adhered to. Otherwise the refrigerator must be installed as described in these instructions.
19 Draught-free inst allation The refrigerator shall be sealed so that fumes cannot enter the living area. Illustrated below are two typical approved methods of sealing.
20 In this case, for gas operation, do not use the upper winter covering! If even with draught-free installation a fume chimney is desirable, you must incorpor- te the L100 ventilation and extraction system into the upper air vent opening . Installation of fume chimney: please refer to point “ 6.
21 Inst alling the ventilation system 6.4 3. Insert the ventilation grilles. 6. Insert winter cover (optional) 2. Insert the frame ... 4. Lock the ventilation grilles. 5. Clip the extractor insert in position (only for upper ventilation system L100) .
22 Inst allation recess The refrigerator must be installed draught-free in a recess (see point “ 6.2 ”). The measurements of the recess are given in the t able below .
23 Fume extraction Fume extraction must be arranged in such a way as to provide complete extraction of all product s of combustion to an area out side the living area. The flue system must slope in an upward direction in order to avoid a build-up of condensation.
Gas inst allation The rules in point 6.1 must be adhered to. When running on gas, these appliances are intended exclusively to use liquid gas (prop ane) - under no circumst ances should town gas or natural gas be used. An AGA Approved LP Regulator must be fitted to the gas supply .
25 Electrical inst allation Electrical inst allation may only be carried out by qualified personnel. The connection cables must be laid in such a way that they do not come in cont act with hot component s of the unit/burner or with sharp edges. The electrical inst allation must comply with national regulations.
26 D+ connection and Solar Control connection ( AES only ) D+ connection The D+ control connection must be connected to the respective vehicle terminal (alternator signal while motor is running). Solar control input (S+): Connection only when using a solar system with a solar charging controller with AES output.
27 Wiring diagram Wiring diagram for RM 7XX1 L - models and RM 7XX5 L - models 6.9.6 Connections: A = Ground heating element DC B = Plus heating element DC C = Ground electronics D = Plus electronics .
Dometic GmbH In der S teinwiese 16 D-57074 Siegen GERMANY www .dometic.com.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Dometic RM 7405 L c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Dometic RM 7405 L - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Dometic RM 7405 L, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Dometic RM 7405 L va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Dometic RM 7405 L, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Dometic RM 7405 L.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Dometic RM 7405 L. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Dometic RM 7405 L ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.