Manuel d'utilisation / d'entretien du produit BRISK AIR 579 SERIES du fabricant Dometic
Aller à la page of 12
1 INST ALLA TION INSTRUCTIONS REVISION: Form No. 3109395.066 8/07 (Replaces 3109395.058) (French 3109660.063) ©2007 Dometic Corporation LaGrange, IN 46761 INST ALLA TION INSTRUCTIONS Lire et comprendre ce manuel avant de procéder à l’installation, à des réglages, de l’entretien ou des réparati ons.
2 INST ALLA TION INSTRUCTIONS SAFETY INSTRUCTIONS This manual has safety information and instructions to help users eliminate or reduce the risk of accidents and injuries. RECOGNIZE SAFETY INFORMA TION This is the safety-alert symbol. When you see this symbol in this manual, be alert to the potential for personal injury .
3 INST ALLA TION INSTRUCTIONS SPECIFICA TIONS 120V AC, 60 HZ., 1PH. 12 AWG Copper up to 24’ * For wire lengths over 24 ft. consult the National Electric Code for proper sizing. ** Dometic Corporation gives GENERAL guidelines for generator requirements.
4 INST ALLA TION INSTRUCTIONS INST ALLA TION INSTRUCTIONS 1. PRECAUTIONS Improper insta llation may damage equipment/could endanger life, cause serious injury and/or property damage. A. Read Installation and Operating Instructions carefully before attempting to start your air conditioner installa- tion.
5 INST ALLA TION INSTRUCTIONS C. AFTER LOCA TION HAS BEEN SELECTED: 1. Check for obstructions in the area where air condi- tioner will be installed. 2. The roof must be designed to support 130 pounds when the RV is in motion. Normally a 200 lb. static load design will meet this requirement.
6 INST ALLA TION INSTRUCTIONS It is the responsibility of the installer of this air condi- tioner system to ensure structural integrity of the RV roof. Never create a low spot on the roof where water will collect. W ater standing around the air conditioner ma y lea k int o the inte ri or caus in g da mage to the pro du ct and the RV .
7 INST ALLA TION INSTRUCTIONS 3. A 3/8” diameter hole will be needed to route the cable through the wall. B. CONTROL CABLE INST ALLA TION A 4-conductor control cable must be routed from the roof opening to the Comfort Control Center ™.
8 INST ALLA TION INSTRUCTIONS 6. DISCHARGE DUCT & CEILING TEMPLA TE INST ALLA TION A. Remove the air box and mounting hardware from their carton. The upper duct is shipped inside the lower duct which is part of the ceiling template. B. Remove the upper duct from the ceiling template and locate it over the blower discharge.
9 INST ALLA TION INSTRUCTIONS TROL KIT A. If your installation included the optional electric heat kit, install it at this time. Follow the instructions with the heat package for its installation procedure. B. T erminate the 4-conductor control cable(s) protruding into the 14-1/4” x 14-1/4” (±1/8”) roof opening.
10 INST ALLA TION INSTRUCTIONS 8. SYSTEM CONFIGURA TION, RESET & CHECKOUT Nowthat thesystem isinstalled, itis necessaryto congurethe elec - tronics and check all operations. Refer to the Operating manual for a description of the air conditioner operation.
1 1 INST ALLA TION INSTRUCTIONS FIG. 16 T wo Zone Conguration FIG. 15 9. AIR BOX INST ALLA TION A. Remove return air grille from air box by pulling in on half- roundngercatches. B. Hold air box up to ceiling template and install three (3) #10 x 3/8” (C) screws at air box mounting point.
12 INST ALLA TION INSTRUCTIONS AIR CONDITIONING UNIT A. (4) 1/4” — #20 x 7” bolts B. (4) #8 x 5/8” long sharp point wood screws C. (7) #10 x 3/8” blunt point tapping screws D.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Dometic BRISK AIR 579 SERIES c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Dometic BRISK AIR 579 SERIES - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Dometic BRISK AIR 579 SERIES, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Dometic BRISK AIR 579 SERIES va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Dometic BRISK AIR 579 SERIES, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Dometic BRISK AIR 579 SERIES.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Dometic BRISK AIR 579 SERIES. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Dometic BRISK AIR 579 SERIES ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.