Manuel d'utilisation / d'entretien du produit 630516.336 du fabricant Dometic
Aller à la page of 16
620515, 620525, 620526, 630515 & 630516 Installation Instructions 1 Important: These Instructions must stay with unit. Owner read carefully. REVISION: Form No. 3309083.032 9/07 (Replaces 3309083.024) (French 3309084.030) ©2007 Dometic Corporation LaGrange, IN 46761 C U S INST ALLA TION INSTRUCTIONS Models 620515.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 2 SAFETY INSTRUCTIONS This manual has safety information and instruc- tions to help users eliminate or reduce the risk of accidents and injuries. RECOGNIZE SAFETY INFORMA TION This is the safety-alert symbol.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 3 620515.331 13,500 1530 12.4 60.0 3.5 10.0 335 / 250 .012 / 0.65 16.5 2 0 A m p 9 5 3.5 KW/5.0 KW 620515.336 13,500 1530 12.4 60.0 3.5 10.0 335 / 250 .012 / 0.65 16.5 2 0 A m p 9 5 3.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 4 A . Precautions Improper installation may damage equipment, could endanger life, cause serious injury and/ or property damage. 1. Read Installation and Operating Instructions care- fully before attempting to start your air conditioner installation.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 5 It is the responsibility of the installer of this air conditioner system to ensure structural integrity of the RV roof. Never create a low spot on the roof where water will collect.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 6 It is the responsibility of the installer to insure the ductwork will not collapse or bend during and after the installation. Dometic Corporation will not be liable for roof structural or ceiling damage due to improperly insulated, sealed or collapsed ductwork.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 7 These items must be determined in conjunction with the Air Distribution System and Sizing and Design Require- ments listed in the chart on page 6. Terminate the start of the duct at the back edge of the 14-1/4" x 14-1/4" (±1/ 8").
620515, 620525, 620526, 630515 & 630516 Installation Instructions 8 D. Wiring Requirements 1. 120 VAC Supply Line Route a copper 12 AWG, with ground, 120 VAC supply line from the time delay fuse or circuit breaker box to the roof opening.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 9 Important: RJ-11-6C4P connectors must be installed as shown in FIG. 8A, 8B & 8C. 3. Comfort Control Center TM Installation a. Carefully remove the base plate from the Com- fort Control Center TM .
620515, 620525, 620526, 630515 & 630516 Installation Instructions 10 CAUTION If bolts are left loose there may not be ad- equate roof seal or if over tightened, damage may occur to the air conditioner base or ceil- ing template. Tighten to specifications listed in this manual.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 11 Improper installation and sealing of divider plate will cause the compressor to quick cycle on the cold control. This may result in fuse or circuit breaker opening and/or lack of cool- ing.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 12 e. Use Aluminum foil tape (not supplied) to seal the ends of the foam divider to the sides of the opening. Make sure the area behind the flange on the ceiling template is sealed.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 13 If bolts are left loose there may not be ad- equate roof seal or if over tightened, damage may occur to the air conditioner base or ceil- ing template. Tighten to specifications listed in this manual.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 14 Installing unit with 3308120 Genesis Air Filtra- tion System Return Air Kit. For 3105007 or 3105935 Return Air Kit, see page 14. 1. Install the slider in the return air cover and raise it to the ceiling template.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 15 J . System Configuration, Reset & Check Out Now that the system is installed, it is necessary to check all operations and then configure the electronics. Refer to the Operating manual for a description of the air conditioner operation.
620515, 620525, 620526, 630515 & 630516 Installation Instructions 16 REAR REM O TE SENS O R ( R e qui re d wi t hS e c on d Ai r C on di t i oner) REAR REM O TE SENS O R ( R e qui re d wi t h S e .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Dometic 630516.336 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Dometic 630516.336 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Dometic 630516.336, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Dometic 630516.336 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Dometic 630516.336, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Dometic 630516.336.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Dometic 630516.336. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Dometic 630516.336 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.