1 INSTALLATION INSTRUCTIONS APPLICA TION MANUAL AND INST ALLA TION INSTRUCTIONS THIS UNIT IS DESIGNED FOR OEM INSTALLATION ALL INITIAL INSTALLATIONS MUST BE APPROVED BY THE SALES DEPT. ROT AR Y COMPRESSOR SYSTEM MODELS Air Conditioners 39626.501 & 39626.
INSTALLATION INSTRUCTIONS 2 TABLE OF CONTENTS: 1.0 SAFETY INSTRUCTIONS ........................................................................... PAGE 3 2.0 APPLICATION MANUAL ..........................................................................
3 INSTALLATION INSTRUCTIONS 1.0 SAFETY INSTRUCTIONS This manual has safety information and instruc- tions to help users eliminate or reduce the risk of accidents and injuries. RECOGNIZE SAFETY INFORMA TION This is the safety-alert symbol. When you see this symbol in this manual, be alert to the potential for personal injury .
INSTALLATION INSTRUCTIONS 4 2.1 AIR DISTRIBUTION 2.1.1 GENERAL INFORMATION The purpose of an air conditioning system is to provide environmental conditions in a space to keep its occupants comfortable.
5 INSTALLATION INSTRUCTIONS 2.1.5 AIR FLOW AND FRICTION Air flows in a duct system from a region of high pressure to a region of lower pressure. The blower creates the pressure differential which causes the air flow through the duct system. The point of highest pressure in the system is at the outlet of the blower.
INSTALLATION INSTRUCTIONS 6 ITEM 1 Sharp Angle ITEM 4 Long Radius Bend ITEM 2 Rounded Outer Corner ITEM 5 Splitters, or turning vanes installed in sharp angle bend ITEM 3 Rounded Corners ITEM 6 Splitters in rounded corner bend EDDIES EDDIES ABRUPT EXPAN- SION SMALL DUCT EDDY LOSSES LARGE DUCT FIG.
7 INSTALLATION INSTRUCTIONS 4. Sudden contractions in air stream 5. Sudden expansions in air stream 2.1.7 REGISTERS, DIFFUSERS, AND GRILLE SELEC- TION One of the most important considerations in designing a conditioning system is the selection of the registers, diffus- ers and grills.
INSTALLATION INSTRUCTIONS 8 It is the responsibility of the installer to en- sure the duct work will not collapse or bend during and after installation. Dometic Corpo- ration will not be liable for any structural dam- age due to improperly insulated, sealed or collapsed duct work.
9 INSTALLATION INSTRUCTIONS 2.5.0 MOUNTING IN COACH The dual basement air conditioner and heat pump are designed for under the floor installation. It is the vehicle manufacturer's responsibility to provide an installation space which will allow for cutouts and mounting of the unit without cutting vital frame structures.
INSTALLATION INSTRUCTIONS 10 System Model 39726.501 & 39726.506* Nominal BTU Capacity 26,000 Volts/Phase/Hertz (each circuit) 115 AC / 1 / 60 Run Amps Comp (Circuit 1 =10.0) (Circuit 2 = 9.8) LRA Compressor (Circuit 1 = 59.0) (Circuit 2 = 59.0) Total Blwr/Fan Motor Run Amps 8.
11 INSTALLATION INSTRUCTIONS C HERM HERM C 3108345.061 FIELD WIRING FIELD WIRING FACTORY WIRING FACTORY WIRING P4 P3 P5 NC P6 COM K6 COM NO K1 F1 P1 P2 NO T3 NC T1 3 AMP FUSE 3 AMP FUSE CIRCUIT CIRCUIT MOTOR COND. BLOWER COND. BLOWER EVAP . BLOWER EVAP .
INSTALLATION INSTRUCTIONS 12 3.1 GENERAL INFORMATION 3.1.1 THIS UNIT IS DESIGNED FOR: A. Installation in a recreational vehicle at the time the vehicle is manufactured. B. Heating operation in a MILD GEOGRAPHICAL AREA where the heat loss is minimal. C.
13 INSTALLATION INSTRUCTIONS Where the return air must be provided through louvers or mesh screen, the FREE AREA percentage of the material used shall be taken into consideration when making this determination. An example of how to determine FREE AREA is included in "3.
INSTALLATION INSTRUCTIONS 14 3.3 ELECTRICAL WIRING E. Circuit #2 should be wired through the on-board generator or a separate power cord dedicated to Circuit #2. Note: A standard 30 amp hookup will not power both Circuit 1 and Circuit 2 and the coach's other major appliances.
15 INSTALLATION INSTRUCTIONS B. Route a dedicated DC supply line (18-22 AWG copper conductors) from the Converter or Battery to the unit's electrical box. Connect with wire nuts positive (+) DC to the red wire; Negative (-) DC to the black wire. C.
INSTALLATION INSTRUCTIONS 16 6. If an Energy Management System - EMS (load shed) is to be used with the control, two wires must be routed to the electrical control box. The signal required for this function is a normally open relay contact. When the EMS calls for the com- pressor to shut off, the relay contacts should close.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Dometic 39626.501 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Dometic 39626.501 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Dometic 39626.501, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Dometic 39626.501 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Dometic 39626.501, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Dometic 39626.501.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Dometic 39626.501. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Dometic 39626.501 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.