Manuel d'utilisation / d'entretien du produit Command Processor Panel du fabricant DMP Electronics
Aller à la page of 26
LT-0230 (2/97) Do Not Throw Away! This programming guide contains information you need to program and service the XR10 panel and should be kept along with your other DMP technical documentation. XR10 Command Processor Panel Programming Guide 10 Zone Burglary/Fire/Access Control Panel with Built-in Communicator 2841 E.
MODEL XR10 PROGRAMMING GUIDE Copyright © 1995 - 1997 Digital Monitoring Products, Inc. Information furnished by DMP is believed to be accurate and reliable.
TABLE OF CONTENTS Introduction .................................................................................................................................................................. 1 1.1 Before Y ou Begin .................................
TABLE OF CONTENTS Section Page 6.1 SYSTEM OPTIONS ................................................................................................................................................ 9 6.2 ALL/PERIMETER ....................................
1 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 1-INTRODUCTION Introduction 1.1 Before You Begin About this Guide This guide provides programming information for the DMP XR10 Command Processor Panel.
2 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 1 - INTRODUCTION 1.4 Programmer Lockout Codes Although the XR10 panel allows you to enter the built-in Programmer without a lockout code, we recommend you install one to restrict programming access to only those persons your company authorizes.
3 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 1 - INTRODUCTION If you are changing a phone number or account number, press the SELECT key followed by the appropriate digit keys.
4 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 2 - INITIALIZATION 2.1 INITIALIZATION This function allows you to set the panel's user codes and Programmer selections back to factory defaults before programming the panel for the first time or a new installation.
5 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 3 - COMMUNICATION 3.6 TEST FREQUENCY Allows you to set how often the panel's test report is sent to the receiver. Enter from 1 to 60 days. Enter zero to disable the test report.
6 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 3.16 PAGER REPORTING YES allows the panel to send Alarm, Trouble, Opening, and Closing reports to a numeric pager. The panel uses DTMF tones to generate the account and report information sent over the pager terminal equipment.
7 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 4 - REMOTE OPTIONS 4.1 REMOTE OPTIONS This section allows you to enter the information needed for Remote Command/Remote Programming operation. A description of the Remote Options follow: 4.
8 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 5.1 SYSTEM REPORTS This section of the Programmer allows you to select the reports the XR10 sends to the receiver. 5.2 OPENING/CLOSING REPORTS YES allows the panel to send opening/closing reports by user to the receiver.
9 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 6.1 SYSTEM OPTIONS This section allows you to select system wide functions of the XR10 system. 6.2 ALL/PERIMETER YES configures the panel as a Perimeter (Area 1) and Interior (Area 2) system.
10 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 7.1 OUTPUT OPTIONS This function allows you to program the panel's Bell Output functions and certain Output options. Switched Ground (open collector) outputs are available from the XR10 when using a 4-wire output harness (Model 300 Harness).
11 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 7.5 OUTPUT ACTION This option allows you to define the operation of the panel's four annunciator outputs. 7.5A CUTOFF OUTPUTS Any or all of the available outputs can be programmed here to turn off after the time specified in OUTPUT CUTOFF TIME .
12 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 8.1 ZONE INFORMATION This allows you to define the operation of each protection zone used in the system. A description of each programming option follows: 8.2 ZONE NUMBER Enter the number of the zone you intend to program.
13 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 8.6 ARM AREAS This option specifies the areas to be armed by the Arming Type Zone.
14 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 8.9A MESSAGE TO TRANSMIT You can send two report types to the receiver: Alarm and Trouble. These are represented by the characters A and T . Press any top row SELECT key to display the zone's report options.
15 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 8.11 ENTRY DELAY Select the entry delay timer for this zone. Entry delay timers 1 and 2 are programmed in section 6.4. 8.12 CROSS ZONE Select YES to enable cross zoning for this zone.
16 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 9.1 STOP At the STOP prompt, pressing any SELECT key allows you to exit the XR10 Programmer. When selected, the panel performs an internal reset and exits the programmer.
17 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 11.1 Status List The Status List is the current status of the system or records of recent system events that are displayed on the alphanumeric keypads. For example, in Home/Away systems, you might see the display SYSTEM READY .
18 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 11.4 Zone Type Specifications This section describes applications for the default zone types in Zone Information programming. The XR10 panel contains 11 default zone types for use in configuring the system.
19 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 11.5 Zone Type Descriptions NT (Night Zone) - Controlled instant zone used for perimeter doors and windows and interior devices such as PIRs and Glassbreak detectors.
20 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 11.7 Default panel programming This program sheets shows the XR10 panel's default program settings.
21 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 XR10 Programming Guide 11.8 4-2 Communication Reports The table below contains a complete list of hexadecimal characters sent using the DMP 4-2 communication format.
22 XR10 Programming Guide 2841 E. Industrial Drive Springfield, MO 65802-6310 800-641-4282 11.10 4-2 Examples The following examples are the actual event codes a central station would receive. The full report would also include the account number and checksum.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté DMP Electronics Command Processor Panel c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du DMP Electronics Command Processor Panel - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation DMP Electronics Command Processor Panel, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le DMP Electronics Command Processor Panel va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le DMP Electronics Command Processor Panel, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du DMP Electronics Command Processor Panel.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le DMP Electronics Command Processor Panel. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei DMP Electronics Command Processor Panel ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.