Manuel d'utilisation / d'entretien du produit DVP-0204520-03 du fabricant 321 Studios
Aller à la page of 44
DVPDNET -SL DeviceNet Network Scanner Operation Manual DVP-0204520-03 2012-3-27.
DeviceNet Network Scanner DVPDNET -SL W arning Please read this instruction carefully before u se and follow this instru ction to operate the device in order to prevent damages on the device or injuries to st aff . Switch off the power before wiring.
DeviceNet Network Scanner DVPDNET -SL 4 CONFIGURA TION OF DVPDNET -SL .................................................................................................... 8 4.1 Configuration through DeviceNet Builder Sof tware ........................
DeviceNet Network Scanner DVPDNET -SL 1 Introduction 1) Thank you for choosing Delt a DVPDNET -SL. T o ens ure correct inst allation and operation of DVPDNET -SL, please read this chapter carefully before usin g your DVPDNET -SL. 2) DVPDNET -SL running on the left side of PLC can se rve as the DeviceNet master or sl ave with PLC MPU together .
DeviceNet Network Scanner DVPDNET -SL 1.3 S pecifications PLC that DVPDNET -SL support s Item S pecification PLC Model DVPDNET -SL supports PLC MPU which can be extendable in it s left side g. DVP-SV , DVP-EH2_L, DVP- SX2, DVP-SA2, DVP10MC1 1T et c.
DeviceNet Network Scanner DVPDNET -SL 2 Product Profile & Outline 2.1 Dimension 3 2 0 1 4 9 8 6 7 0 MS NS 5 DR 0 DR 1 x10 IN 1 IN 0 DVPDNET x10 5 3 2 4 0 1 8 6 7 9 1 2.2 Product Profiles 1. Model name 2. Extension port 3. Power , MS, NS LED 4. DIN rail clip 5.
DeviceNet Network Scanner DVPDNET -SL 2.4 Address Switch The switch is used on setting up the node address of DVPDNET -SL on DeviceNet. Range: 00 ~ 63 (6 4 ~ 99 are forbidden).
DeviceNet Network Scanner DVPDNET -SL 2.6 Digit al Indicator The digital indicator provid es the following two functions: DVP DNE T POW ER MS NS 1) Displaying the node address and er ror messages of DVPDNET -SL . 2) Displaying the error message of slave.
DeviceNet Network Scanner DVPDNET -SL 3 Inst allation 3.1 Connecting DVPDNET -SL to DVP-SV MPU Adjust the extension clip on the lef t side of DVP-SV . Meet the extension port of the MPU with DVPDNET -SL as shown in the figure below . Fasten the extension clip.
DeviceNet Network Scanner DVPDNET -SL 3.3 Connecting to DeviceNet Connection Port The colors on the PINs on the Device Net connection port match the colors of the connection cables. Make sure you conne ct the cable to the right PIN. We recommend you also a pply Delta’ s power module in the connection.
DeviceNet Network Scanner DVPDNET -SL 4 Configuration of DVPDNET -SL 4.1 Configuration through De viceNet Builder Software Before DVPDNET -SL starts to work normally , it must be configured through DeviceNet Builder software.
DeviceNet Network Scanner DVPDNET -SL 4.1.2 Setup of Scan Module The following dialog is for setting DVP DNET -SL ’s current mode: master mode or slave mode.
DeviceNet Network Scanner DVPDNET -SL 4.1.3 Setup of Scan List Double click the existing icon of DVPDNET -SL in the DeviceNet Builder inte rface and then the following dialog box appears for conf iguring the scan module. Parameter Explanation Available node All already scanned slaves appear in “A vailable list”.
DeviceNet Network Scanner DVPDNET -SL 4.1.4 Input T able and Output T able Select the device in “Scan list” and then the dat a leng th of input and output of the device will be displayed respectively in the lower part of the following di alog box.
DeviceNet Network Scanner DVPDNET -SL 4.2 Dat a Mapping Areas The data ma pping introduced in this chapter is the dat a mapping between PLC MPU and DV PDNET -SL. The mapping relation is unch anged and user has n o right to revise this area. Max 8 PLC DVPDNET -SL modules can be connected to PL C’ s left side.
DeviceNet Network Scanner DVPDNET -SL Note: If the unit No. is 2, the number of the registers a bove will all be adde d by 500 respectively; if the unit No. is 3, the number of the registers abov e will all be added by 1000 respectively; if the unit No.
DeviceNet Network Scanner DVPDNET -SL 5 Sending Explicit Message from Ladder Diagram DVPDNET -SL supports the sending of explicit messages through WPL programs.
DeviceNet Network Scanner DVPDNET -SL 5.2 S tructure of Explicit Message Y ou can edit explicit messages in “explicit request m e ssage editing area” and “explicit re sponse message editing area”. See the table below for the correspondi ng relation betwee n the two areas and P LC devices.
DeviceNet Network Scanner DVPDNET -SL 2) S tructure of respon se message See the table below: Response Message PLC device 15 14 13 12 11 10 987 6 5 4 3 2 1 0 D6000 ReqID S tatus D6001 Port Size D6002 .
DeviceNet Network Scanner DVPDNET -SL 4) Application ex ample (I) Target When M0 = On, read Class 1>>I nstance 1>>Attribute 1 of IFD9502 1> The connecti on DVPDN ET DVP28 S V RUN STO P Devi ceN et RJ12 Node Address:00 Node Address:02 Note: IFD9502, a Delta De viceNet slave module can connect VFD AC motor drive to DeviceNet network.
DeviceNet Network Scanner DVPDNET -SL Explanations on devices Explanation PLC device Content 15 14 13 12 11 10 9876 5 4 3 2 1 0 D6250 0101Hex ReqID = 01Hex Command = 01Hex D6251 0005Hex Port = 00H.
DeviceNet Network Scanner DVPDNET -SL 5) Application ex ample (II) Target M1 = On, set 0x99>>Instance 1>>Attri bute 2 of IFD9502 to “0004Hex”. 1> The connecti on Note: IFD9502, a Delta De viceNet slave module can connect the temperature controller to Device Net network.
DeviceNet Network Scanner DVPDNET -SL Explanations on devices Explanation PLC device Content 15 14 13 12 11 10 987 6 5 4 3 2 1 0 D6250 0101Hex ReqI D = 01Hex Command = 01Hex D6251 0005Hex Port = 0.
DeviceNet Network Scanner DVPDNET -SL When M1 = On, DVPDNET - SL will only send out request message once. If you would like it to send out request message again, y ou will have to cha nge ReqID. When the writing is successfully done, the me ssage responded fro m the target equipment will be stored in D6000 ~ D6003.
DeviceNet Network Scanner DVPDNET -SL 6 Bit-S trobe Command 6.1 Principle of Bit-S trobe Bit-strobe is one of the st andard I/O transmission methods for DeviceNet. The length of command is fixed to 8 bytes (i.e. 64 bits), and eve ry bit corresponds to a slave.
DeviceNet Network Scanner DVPDNET -SL 7 Display of Node S tatus on Network 7.1 Display of Node S tatus in Scan List This function is to monitor if DeviceNet slave is off line or not. DVPDNET -SL does read-time monitoring to the nodes in the scan list and map s the status of ever y node to a bit.
DeviceNet Network Scanner DVPDNET -SL 8 Setup of Slave Mode DVPDNET -SL can serve as slave through modifying of t he mode by sof tware. As DVPDNET -SL serves as slave, the default input / output data length i s 8 bytes and max input / output data length is 255 bytes.
DeviceNet Network Scanner DVPDNET -SL 4) Select “Network” => "Online” and the “Select Comm unicatio n Channel” dialog bo x will appear . Click on “OK” to start scanni ng the DeviceNet network af ter selecting “analog onli ne” in the following windo w .
DeviceNet Network Scanner DVPDNET -SL 9 Setup of Extended Baud Rate 9.1 Setup of Extended Ba ud Rate (as master mode) 1) Connect the device to the Devicenet network a ccord ing to the following figure.
DeviceNet Network Scanner DVPDNET -SL 5) Select “Network” => "Setup of scan module” and the following "Setup of scan m odule” dialog box appears. Select “Master mode” and “S tartup” to activate the f unction of extended baud rate.
DeviceNet Network Scanner DVPDNET -SL 9.2 Setup of Extended Baud Rate (as slave mode) 1) Con nect the relevant devices to the Device Net network according to the following figure. DVP 28 S V DVP DNET - S L( Mas t e r ) De vi ce Net Bui l der De vi ceN et DV P 28S V DVP DNET- S L( Sl av e ) Note: a.
DeviceNet Network Scanner DVPDNET -SL 3) Set up the co mmunication paramete rs in the PC and DVP-SV , e.g. the communication p ort, address, baud rate and communication format.
DeviceNet Network Scanner DVPDNET -SL 6) Set parameter 5 as “Enabl e” and select the baud rate in p arameter 6 in the following pag e. Click on “Download” to download the ne wly set parameter value to DVPDNET -SL ( Sl ave ) . 7) Af ter download is completed, set DVPDNET -SL ( Slave ) ’s function switch: DR0 and DR1 as ON.
DeviceNet Network Scanner DVPDNET -SL 10 Application Example on Constructing DeviceNet Network In this section, we will present an application example, illustrating how to construct a DeviceNet netwo rk and the configuration of the network. Target Using an X point of DVP28SV to control RUN/ST OP of the remote VFD-L AC motor drive.
DeviceNet Network Scanner DVPDNET -SL VFD-L para met er Set value Explanation 02-00 4 T ransmit the frequency of VFD-L via RS485 communication. 02-01 3 Control operation of VFD-L via RS485 communication. 09-00 1 Set the node address of VFD-L in Modbus to 1.
DeviceNet Network Scanner DVPDNET -SL 3> Select “Network” => "Online”, and the “Select Communicatio n Channel” dialog box will appea r.
DeviceNet Network Scanner DVPDNET -SL 5> Double click on R TU-DNET (node 02), and the "Nod e Configuration…” dialog box will appear . 6> Click on “IO Configure… ” button in “Nod.
DeviceNet Network Scanner DVPDNET -SL 8> In the interface of “Modbus gat eway setting”, use the parameters of one sl ave and fill the relevant values there. You can refer to the user manual of RTU-DNET. Note: The sla ve here is the slave in Modbus n etwor k without direct relation with DeviceNet network.
DeviceNet Network Scanner DVPDNET -SL 2) Configuration of DeviceNet Master 1> Double click on DNET Scanner (node 01), and the “Scan Module Configur ation..." dialog box will appear . Y ou can find the currently available nodes , RTU-DNET and VFD-B Drives 230V 3HP , in the list on the left side.
DeviceNet Network Scanner DVPDNET -SL 3> Confirm all the settings and click on “O K”. Ne xt, download the configuration to DVPDNET -SL. If DVP-SV is in RUN mode while you are downloadin g the configuration, a “W arning” dialog box will appear .
DeviceNet Network Scanner DVPDNET -SL 10.3 Ladder Diagram Program This section introdu ces how to edit the ladde r diagram prog ra m to meet the control reque st of DeviceNet network.
DeviceNet Network Scanner DVPDNET -SL 11 LED Indicator & T rouble-shooting DVPDNET -SL supports two diagnostic methods: indicator diagnosis and digit al displayer diagnosis. DVP DNET POW ER MS NS 11.1 LED Indicator Diagnosis POWER LED LED status Indication How to correct Off Power is abnormal.
DeviceNet Network Scanner DVPDNET -SL MS & NS LED LED status NS LED MS LED Indication How to correct Off Off No power Make sure DVPDNET -SL i s powered. Make sure at least 1 node or more are communicating in the net work, and the baud rate is the same as the set ting in DVPDNET -SL.
DeviceNet Network Scanner DVPDNET -SL Code Indication How to correct E2 Slave device in the scan list does not exist or is of fline. 1. Check if there is any change for the nod e address of the slave. 2. Check if the communication cabl e is disconnected or connected loosely .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté 321 Studios DVP-0204520-03 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du 321 Studios DVP-0204520-03 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation 321 Studios DVP-0204520-03, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le 321 Studios DVP-0204520-03 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le 321 Studios DVP-0204520-03, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du 321 Studios DVP-0204520-03.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le 321 Studios DVP-0204520-03. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei 321 Studios DVP-0204520-03 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.