Manuel d'utilisation / d'entretien du produit 90031300 du fabricant Digi
Aller à la page of 160
Part No: 90031300 Rev C Digi International Inc. AccelePort T1 Modem Bank Installation and Configuration Guide.
The Digi logo is a registered trademark of Digi International Inc. AccelePort ™ , T1 Modem Bank ™ and EPC/X ™ are tradem arks of Digi International Inc. All other brand and product names are the trademarks of their respective holders. © Digi International Inc.
Contents iii Table of Contents Regulatory Statements ................................................................................................................................................. viii Federal Communications Commission (FCC) Statement .
iv T1 Modem Bank Software Installation for Novell Systems...............................................................................................................34 Introduction ...................................................................
Contents v Physical Specifications .................................................................................................................................................. 79 T1 Modem Bank Power Cord Specifications ..........................
vi T1 Modem Bank List of Figures Figure 1 T1 Modem Bank Chassis, Front View.......................................................................................................1 Figure 2 Power Supply .................................................
Contents vii List of Tables Table 1 T1 Modem Bank Shipping Carton Contents..............................................................................................2 Table 2 CSU Technical Description ...............................................
viii T1 Modem Bank Regulatory Statements Federal Communications Commission (FCC) Statement Radio Frequency Interference (RFI) This equipment generates and uses radio frequency energy, and if not installed and used in strict accordance with manufacturer’s instructions, may cause interference to radio and television reception.
Regulatory Statements ix FCC Part 68 FCC Registration: 5TLUSA-23932-DD-N Ringer Equivalence Number: 0.0B This T1 Modem Bank complies with Part 68 of FCC Rules. On the back of the T1 Modem Bank is a label that includes the FCC Registration Number and Ringer Equivalence Number (REN) for this T1 Modem Bank.
x T1 Modem Bank Industry Canada Compliance Statement This Class A digital apparatus meets the requirem ents of the Canadian Interference-Causing Equipment Regulations. It complies with CSA 22.2 No. 950 for safety, ICES 003 for EMC, and ICCS 003 for Telecom.
Overview 1 AccelePort T1 Modem Bank Overview The Digi AccelePort T1 Modem Bank is a high speed Wide Area Network (WAN) interface for Windows NT and Novell environments. The T1 Modem Bank system is composed of two major parts: a host-installed Enhanced Performance Concentrator (EPC/X) adapter and a rack mountable or table top system cabinet.
T1 Modem Bank 2 Unpacking Table 1 documents typical shipment packaging contents of the T1 Modem Bank. The components should be checked in upon arrival; notify your salesperson if the order is incomplete. The T1 Modem Bank is shipped with proper shock insulation material.
Planning the T1 Interface 3 Planning the T1 WAN Interface This section describes planning the T1 Modem Bank interface to the carrier facility. The configuration of the T1 Modem Bank must match the requirements of the T1 line specified by the carrier.
T1 Modem Bank 4 Line Build Out After the T1 Modem Bank is installed, the carrier will determine the correct setting for Line Build Out (LBO). However, certain determinations based on the following information will need to be entered into your computer.
Planning the T1 Interface 5 Parameters Specified to the Carrier Certain parameters are specified to the carrier when provisioning the T1 line. You will need to provide the following information to a T1 facility provider.
T1 Modem Bank 6 Planning Worksheets The T1 Modem Bank must be configured to match the provisioning of the T1 line from the carrier. General Information Required information includes the following: •.
Planning the T1 Interface 7 T1 Modem Bank Worksheet Type Number or Checkmark ( √ ) Description Circuit ID # __________________ This is a code assigned by your service provider, one per T1 line Lead phone number __________________ Master phone number or first phone in the sequence to receive a call.
T1 Modem Bank 8 Hardware Installation This section describes the following procedures: 1. T1 Modem Bank power supply installation/replacement 2. T1 Modem Bank standalone or rack installation 3. T1 Modem Bank daisy chaining 4. EPC/X host adapter installation 5.
Hardware Installation 9 Figure 2 Power Supply • You can install a second power supply into a T1 Modem Bank that already has an existing power supply installed without having to power-down the T1 Modem Bank. • Wear a grounding strap while performing this procedure to prevent electrical discharge.
T1 Modem Bank 10 T1 Modem Bank Standalone or Rack Installation You have the option of using the T1 Modem Bank in a standalone, table-top configuration or in a rack-mounted configuration. Directions for both configurations are provided in this section.
Hardware Installation 11 Standalone Installation Procedure Tools needed: Phillips screwdriver; flat blade screwdriver 1. Place the T1 Modem Bank on a flat surface within 6’ 7” (2m) of a power outlet. 2. Attach the terminator plug to the connector labeled HOST OUT on the HOST IN/OUT and Terminal faceplate.
T1 Modem Bank 12 Requirements for Rack Installations The T1 Modem Bank chassis is made to be inserted into a standard 19-inch or a 24-inch equipment rack. The T1 Modem Bank is shipped from the factory with two rack-m ounting brackets (“ears”) installed for a 19-inch rack.
Hardware Installation 13 3. Line up the circular holes in a bracket with the circular holes on a side of the T1 Modem Bank, and use two of the screws to fasten the bracket to the chassis. Do not use the oval slots on a bracket to connect the bracket to the T1 Modem Bank.
T1 Modem Bank 14 General Rack Installation Directions • When multiple units will be m ounted in the rack, install a T1 Modem Bank unit in the first chassis slot at the bottom of the rack, then work upward. This prevents cables from becoming tangled, and it m aintains the lowest possible center of gravity to prevent the rack from falling over.
Hardware Installation 15 1. Installing the T1 Modem Bank into the rack requires two people since the T1 Modem Bank is heavy. Note that handles are provided on the T1 Modem Bank to aid in rack installation. They are part of the chassis and are located on the front of the T1 Modem Bank near the outer edges of the chassis.
T1 Modem Bank 16 Daisy Chaining T1 Modem Bank Units The HOST OUT connector of each unit m ust be connected to the HOST IN connector of the next unit in the daisy chain. A terminator plug is then installed on the HOST OUT connector of the last unit in the daisy chain.
Hardware Installation 17 Daisy Chain Example While setting up daisy chains, refer to the example shown in Figure 9 and the directions that follow. Figure 9 Two Daisy Chains of T1 Modem Banks to be Con.
T1 Modem Bank 18 • Do not connect wires to pins 12 or 13 in a standard daisy chain cable—serious damage could result. • Never use VGA extension cable or any other cable that has all 15 pins wired.
Hardware Installation 19 Daisy Chaining T1 Modem Bank Units and EPC/CON-16 Concentrators A T1 Modem Bank can be installed in an existing system comprised of EPC/CON-16 concentrators.
T1 Modem Bank 20 EPC/X Host Adapter Installation The Digi EPC/X host adapter is an intelligent dual-channel synchronous communication board which plugs into a slot in your computer’s bus. The adapter provides an interface between the computer and a single T1 Modem Bank or a series of daisy-chained T1 Modem Banks and/or EPC concentrators.
Hardware Installation 21 ISA Host Adapters Setting the I/O Port Address The ISA EPC/X host adapter uses four bytes of address space on the host computer’s I/O bus. Before installing the host adapter, the board’s I/O port starting address m ust be set on DIP switch SW1 (located on the top of the board).
T1 Modem Bank 22 Factory-Set Jumper J1 There is one jumper, J1, on the host adapter. This jumper is set in the factory and must not be changed. Installing the ISA Host Adapter in your Computer 1.
Hardware Installation 23 EISA Host Adapters Factory-Set Jumpers There are three jum pers, J1-J3 on the EISA EPC/X host adapter. These are set in the factory, and must not be changed. Installing the EISA Host Adapter in your Computer 1. Turn off your computer and disconnect any attached peripheral devices.
T1 Modem Bank 24 6. Place the cursor on “ Dual-Ported Mem Address ” and press <Enter>. A screen similar to the following will appear: The following address choices are available: Below 1 Meg.
Hardware Installation 25 Connecting the EPC/X Host Adapter to the T1 Modem Banks To locally connect the EPC/X Host Adapter to the T1 Modem Bank(s), connect the daisy chain cable from the EPC/X host adapter line connector to the HOST IN connector on the first T1 Modem Bank in the daisy chain.
T1 Modem Bank 26 To connect the EPC/X host adapter to the T1 Modem Bank(s) via modems, follow the example in Figure 14. Figure 14 Local and Remote T1 Modem Bank Units TM TM TM TM TM TM TM /LQH /LQ.
Software Installation 27 Software Installation and Configuration Setting the Node Number The EPC/X host adapter identifies T1 Modem Bank units and/or EPC concentrators by their node num bers, which are stored in non-volatile RAM (NVRAM).
T1 Modem Bank 28 Figure 16 T1 Modem Bank Display Panel Pressing the right push button will interrupt the power-on self test (POST) of a T1 Modem Bank and let you enter the configuration/diagnostic mode so that you can change the T1 Modem Bank’s node num ber.
Software Installation 29 Installing Download Cycle the T1 Modem Bank’s power off, then on again to restart POST. After a brief pause, the lights on the display panel will flash, and the T1 Modem Bank will begin the POST sequence, which takes about 2 minutes to com plete.
T1 Modem Bank 30 POST Failure If the T1 Modem Bank does not pass POST, it will display an error message code on the seven-segment LED display and enter an infinite loop, waiting for the device to be reset. (Table 4 shows a list of the possible error m essage codes).
Software Installation 31 Possible Problem If at least one m odem card is not inserted in the T1 Modem Bank unit, the line card will busy out the lines associated with that line card. Restarting POST Cycle the T1 Modem Bank’s power off, then on again to restart POST.
T1 Modem Bank 32 Table 5 Display Panel Status Codes 7 Segment Display Meaning Description AC Activity AC appears on the 7-segment display. The ten activity LEDs turn on sequentially from left to right. The speed of this “chase light” display increases with the overall activity level of the T1 Modem Bank.
Software Installation 33 Table 5 (continued) 7 Segment Display Meaning Description SE* Severely Errored Seconds A Severely Errored Second is a second with 320 or more CRC errors FS* Framing Bit Errors.
T1 Modem Bank 34 Software Installation for Novell Systems Introduction Before software installation can proceed: • The EPC/X adapters must be installed in the computer. • The T1 Modem Banks must be connected to the EPC/X host adapters. • The T1 Modem Banks must be powered on.
Software Installation 35 Installing the EPC/X AIO Device Driver See the AccelePort EPC/X device driver installation instructions in the Digi AccelePort Intelligent Serial Communications Products Novell AIO Device Driver Package Software Manual (manual part no.
T1 Modem Bank 36 Configuring the T1 Modem Banks • The instructions for configuring and managing T1 Modem Banks with QuickManager are in “ Configuring via QuickManager” on page 41. • Configuring the T1 Modem Banks with the DGT1CFG.NLM utility is described in this section.
Software Installation 37 3. Press the ENTER key to configure that host adapter’s T1 Modem Banks. The “#” field in the example screen shown in Figure 18 indicates the number (beginning with 0) of the T1 Modem Bank you will be configuring. Figure 18 T1 Modem Bank Configuration Screen 4.
T1 Modem Bank 38 Software Installation for Windows NT Systems Software installation and configuration for a Windows NT system involves the following steps: 1. Install and configure the EPC/X Windows NT device driver on the host system (the system to which the T1 Modem Banks are directly connected).
Software Installation 39 Windows NT 4.0 1. Double click Control Panel. 2. Double click the Network icon. 3. When the “Network” window appears, select “Services”, then click the “Add” button.
T1 Modem Bank 40 To run the setup program, insert the setup disk (part no. 40001468) into the drive and run SETUP.EXE. Setup will perform the following steps: 1. Install local and remote management support files. 2. Install and run the ConfigWizard configuration utility.
Software Installation 41 T1 Modem Bank Configuration The T1 Modem Bank can be configured in the field for specific network needs by one of four methods: • QuickManager mode • DGT1CFG.NLM mode (used on Novell systems only). See “ Configuring the T1 Modem Banks” on page 36 for instructions on using the DGT1CFG.
T1 Modem Bank 42 Figure 19 Line Card Status Display.
Software Installation 43 Figure 20 shows an example screen when “Line Card” and “Options” are selected. Figure 20 Line Card Options Display Once the desired settings have been selected for a com ponent, they must be applied to the T1 Modem Bank.
T1 Modem Bank 44 Configuring via the Terminal Port To configure the T1 Modem Bank through the terminal port, follow these steps before starting up the T1 Modem Bank: 1. Make sure the T1 Modem Bank is shut off; then connect a terminal to the terminal port.
Software Installation 45 Configuring via the Display Panel Power up the T1 Modem Bank and press the right push button on the display panel soon after the adjacent lights flash.
T1 Modem Bank 46 The following describes the display panel configuration/diagnostic process: 1. Press Right Displays current node number Press Left changes node number 2. Press Right Line Card T1 Line Select Press Left selects Line Interface or Drop & Insert 3.
Software Installation 47 Configuring via the Serial Port Interface The serial port on the T1 Modem bank can be used to display and modify the T1 configuration. It can also be used to display the installed equipm ent list, the m odem on/off-hook status, and the alarm status.
T1 Modem Bank 48 The initial screen is shown below. ----------------------------------------------------------------------------- Modem Bank Configuration ---------------------------------------------.
Software Installation 49 Configuration modification For each parameter, the currently active value will be shown in square brackets. Each modifiable parameter has a “ selector” number associated with it and displayed on the left m argin. For example, the parameter “Span Type” has the selector value 5.
T1 Modem Bank 50 ( The user stores the new configuration and makes it “active” by entering “s” ) : s ----------------------------------------------------------------------------- Modem Bank Co.
Software Installation 51 Equipment List To see a display of installed components with their software and hardware revisions and status, the user types the command letter “ e” at the comma nd prompt. There are four component types that can be displayed: m otherboard, line card, power supply and modem cards.
T1 Modem Bank 52 System Information The user can choose to see a display of modem bank system information. An example of the system BIOS/NVRAM information screen is given below.
Software Installation 53 Modem Switchhook Status The user can choose to see a dynamically updated display of the modem switchhook status for each com port. The screen is updated once per second. A “spinner” will be visible on the left margin to provide a visible heartbeat indicating that updating is in progress.
T1 Modem Bank 54 Alarm Status The user can choose to see a continuously updating display of the modem bank’s alarm and loopback status. As with the modem switchhook status display, the screen is updated once per second.
Software Installation 55 An example of the alarm and loopback status display when there are alarm s is shown below. In this case no loopbacks are active.
T1 Modem Bank 56 T1 Modem Bank Diagnostics The T1 Modem Bank features three methods of running its on-board diagnostic programs: • QuickManager mode • display panel mode The tests are selected and.
Diagnostics 57 Running Diagnostics with QuickManager QuickManager is started by clicking the “ Digi” program group, and then clicking the QuickManager icon. Clicking “Window” in the main m enu will allow you to view the current configuration settings, change the configuration settings, or run a test on the selected component.
T1 Modem Bank 58 Running Diagnostics from the Display Panel To run the internal diagnostic programs from the T1 Modem Bank’s front panel, turn the T1 Modem Bank on and wait for the POST (Power On Self Test) to complete. While P1 is displayed on the front panel, press either button on the display panel.
Diagnostics 59 Running Diagnostics from the Terminal Port 1. To run the internal diagnostic programs from the terminal port, turn off the T1 Modem Bank and connect a terminal to the terminal port. Some terminals will not transmit data if their CTS (Clear To Send) line is LOW.
T1 Modem Bank 60 The results of the POST sequence are displayed, and the T1 Modem Bank begins listening for a ping packet from the EPC/X host adapter. While listening for a ping packet, the T1 Modem Bank cycles through various baud rates and clocking modes as it tries to link up with the EPC/X host adapter.
Diagnostics 61 To run individual tests, enter the test number ( 1 - 9 ). To run all tests (except number 9), enter A . Tests run continuously. To stop a test, press any key during execution of the test. The current pass of the test will be completed, and control will be returned to the terminal.
T1 Modem Bank 62 Diagnostic Test Descriptions Test 1: Front Panel Test This test activates the ten LED indicators and the two 7-segment displays in four different patterns at 1-second intervals: the f.
Diagnostics 63 Test 4: Line Card Test The line card test checks to make sure a line card is installed and working. To begin the test in front panel mode, press the left push-button while the number 4 is displayed in the 7-segment LED display. When run from the front panel, the pass number is shown on the 7-segm ent display.
T1 Modem Bank 64 Test 7: Sync External Loopback Test This test places the high-speed synchronous channel in external loopback mode. In video mode, this test can be run with or without an external loopback cable. The external loopback test checks the internally clocked and self clocked transmission modes (0-2, 6-14, 27-29 and 60-74).
Component Removal and Installation 65 Component Removal and Installation This section provides replacem ent instructions for various com ponents. The line card, modem card, power supply, fan assembly, and fuse may be replaced by any on-site personnel of average skill.
T1 Modem Bank 66 Line Card Removal and Replacement These instructions are provided in the event that the line card needs to be replaced in the field due to equipment malfunction. If the line card is malfunctioning, a message number E6 will flash in the display panel window or the boot will not proceed past the D0 state.
Component Removal and Installation 67 The line card is located on the left as you face the front of the chassis. It is accessed from the front of the chassis. A power indicator LED and a T1 jack are part of the line card faceplate. Follow this procedure to replace the line card: 1.
T1 Modem Bank 68 Modem Card Removal and Installation/Replacement Modem Card Removal Modem cards can be “hot swapped”, m eaning that no system reset is needed after a modem card is pulled out and replaced with another modem card.
Component Removal and Installation 69 Figure 23 Modem Card.
T1 Modem Bank 70 Modem cards are located on the front of the chassis between the line card (labeled T1 and PWR) and the sync and terminal connections (labeled HOST IN, HOST OUT and TERMINAL). Six on-line indicators and one power indicator are found on the modem card faceplate.
Component Removal and Installation 71 Figure 24 Quick Manager Modem Revision Screen 2. There are two captive fasteners that secure the modem card to the chassis. To remove the modem card, use a flathead screwdriver to loosen the captive fasteners on the malfunctioning m odem card.
T1 Modem Bank 72 Perform the following steps to install a modem card: 1. Before installing an additional modem card into an empty slot, you m ust remove the faceplate covering the slot. Loosen the captive screws from the faceplate using a flathead screwdriver and lift off the faceplate.
Component Removal and Installation 73 Power Supply Removal There are two ways to check a power supply failure: • Use QuickManager • Check the LED on the power supply’s printed circuit board. An unlit LED indicates that the power supply has failed.
T1 Modem Bank 74 Figure 25 Power Supply.
Component Removal and Installation 75 Fan Assembly Removal and Replacement If the T1 Modem Bank overheats or exceeds its operating range, the fan is probably malfunctioning. If this is the case, follow the procedure below. Wear a grounding strap while performing these procedures to prevent electrical discharge.
T1 Modem Bank 76 Fuse Replacement A defective fuse is indicated by a total loss of power to the system. The fuse is located at the rear of the unit behind the AC power inlet filter. A diagram of the AC power inlet filter is shown below. Figure 27 AC Power Inlet Wear a grounding strap during this procedure to prevent electrical discharge.
Connections to the Telephone Network 77 Connections to the Telephone Network Figure 28 illustrates connections to the PSTN (Public Switched Telephone Network) using the T1 Modem Bank. With PSTN, a modem m odulates serial data into voice-like signals for transmission.
T1 Modem Bank 78 Alarms on a T1 Span Alarm Reason for Alarm Result of Alarm Red Alarm The T1 Modem Bank is not receiving a valid signal from the T1 Line. The T1 Modem Bank sends a “Yellow Alarm” down the T1 line, and it will not accept calls or dial out.
Physical Specifications 79 Physical Specifications T1 Modem Bank Power Cord Specifications The chassis has a 3-wire power cord. The free end of the 3-wire power cord connects to the 110 VAC (domestic) power source and protective ground. NEMA plug type 5/15P is used for US installations.
T1 Modem Bank 80 T1 Modem Bank Environmental Requirements The T1 Modem Bank meets all functional requirements in this m anual when operating in the environment listed below: Ambient Temperature 0° C .
Physical Specifications 81 Daisy Chain Cables Daisy Chain cables have the following attributes: • Twisted pair, overall shield, 28 AWG • Capacitance 15.
T1 Modem Bank 82 T1 Modem Bank Certification The T1 Modem Bank is certified to meet the following electromagnetic emissions and safety standards: Emissions: USA: FCC Part 15, Subpart J, Class A Canada: CSA C108.8-M83, Class A Cispr 22, Class A EN55022 Safety: USA: UL 1950 Canada: C22.
Glossary 83 Glossary AMI (Alternate Mark Inversion) a line coding method for T1 spans. bandwidth the difference between the highest and lowest frequencies in a given range; the maximum data- carrying capacity of a circuit. (Greater bandwidth indicates higher speed data-transfer.
T1 Modem Bank 84 network a collection of links, nodes, and computers that provide connections between two or more defined points to facilitate telecommunication between them.
Appendix A 85 Appendix A — Memory Conflicts Contention for Memory Addresses Many intelligent peripheral devices require a block of vacant memory addresses on the host com puter’s bus for their own use.
T1 Modem Bank 86 Figure 30 Typical PC Memory Usage - 1st Megabyte A0000h AFFFFh B0000h BFFFFh C0000h C8000h D8000h CFFFFh C7FFFh D7FFFh D0000h DFFFFh E0000h EFFFFh F0000h FFFFFh ESDI Hard Disk Drive SCSI Interface EGA/VGA ROM BIOS System BIOS BIOS Extensions (EBIOS) EMM, LIM 4.
Appendix A 87 ISA Host Adapters The Digi ISA EPC/X host adapter has 1 m egabyte of on-board dual-ported RAM which is accessed through a 32K “window”, which can be mapped into any 32K region in the com puter’s mem ory address space (32K byte boundaries end with either 0000h or 8000h).
T1 Modem Bank 88 EISA Host Adapters The Digi EISA EPC/X host adapter has 1 megabyte of on-board dual-ported RAM which is accessed through a 32K “window”, which can be mapped into any 32K region in the computer’s mem ory address space up to the 4 gigabyte limit.
Appendix B 89 Appendix B — Transmission Modes The EPC/X host adapter and the T1 Modem Bank transmit synchronous data in one of 75 m odes. These modes are numbered 0 - 74, and each corresponds to a specific combination of wiring mode (4-Wire or 8-Wire), clocking method (internal, external or self-clocking) and baud rate.
T1 Modem Bank 90 4-Wire, Self Clocked Mode# Mode Baud Rate Mode# Mode Baud Rate 1 NRZI 230K 64 NRZI 460K 2 FM 460K 65 FM 460K 60 NRZI 115K 66 NRZI 921K 61 FM 115K 67 FM 921K 62 NRZI 230K 68 NRZI 1843K.
Appendix C 91 Appendix C — Terminal Port Cable Some terminals will not transm it data if their CTS (Clear To Send) line is LOW. These terminals m ust have their CTS line HIGH or floating to ensure that they will have no problems com municating with the T1 Modem Bank.
T1 Modem Bank 92 Appendix D — Specifications and Wiring Pin Diagrams Line Card Connector Figure 32 illustrates an RJ-45 plug that can be inserted into the T1 line card connector. Figure 32 RJ-45 Plug The following are pin assignments for the T1 line interface and the DSX-1 line interface.
Appendix D 93 Connector for Sync Channels The following is a pin out of the serial channel of SCA and sync link input Signal Pin Signal Pin TxD+ 1 TxD- 2 RTS+ 3 RTS- 8 TxC- 4 TxC+ 5 RxD- 6 RxD+ 7 RxC- 9 RxC+ 10 CTS- 14 CTS+ 15 GND 12 reserved 11 Terminal Port The following pin connections are used for the terminal port.
T1 Modem Bank 94 Appendix E — Generic T1 Modem Bank Wiring Modes There are three basic wiring modes for connecting T1 Modem Bank units to an EPC/X host adapter or to each other: Eight-Wire Direct, Four-Wire Direct (also called Four-Wire Self-Clocking), and Eight-Wire Synchronous Modem (or Eight-Wire Externally Clocked).
Appendix E 95 Four-Wire Direct Wiring Four-Wire Direct wiring connects T1 Modem Bank units where longer synchronous cable runs are necessary. While not as fast as Eight-Wire connections (the maximum data transfer rate is 1.
T1 Modem Bank 96 Restrictions on Daisy Chain Cable Lengths The maximum length of a daisy chain is dependent upon the synchronous data rate. Table 8 lists the maxim um cumulative daisy chain cable lengths for various baud rates.
Appendix E 97 Eight-Wire Synchronous Modem Wiring Eight-Wire Synchronous Modem wiring allows T1 Modem Bank units to be installed in rem ote locations and connected to the EPC/X host adapter via RS-232 or RS-422 synchronous modems.
T1 Modem Bank 98 RS-422 synchronous modems can also be used with the EPC system. The required cables are shown in Figure 36. Figure 36 RS-422 Synchronous Modem Cables The RS-422 Synchronous Modem cables are twisted pair cables, each having an HD-15 (high-density DB-15) connector at one end and a DB-37 connector at the other end.
Appendix F 99 Appendix F — Modem AT Command Set Default values of command param eters, if applicable, are indicated by an asterisk (*). Basic AT Commands A/ Repeat Last Command Repeats execution of the previous command string. “ A/ ” must not be preceded with AT, or followed by pressing <Enter>.
T1 Modem Bank 100 D n Dial Command Initiates the dialing sequence. The string n includes the dial modifiers and the telephone number to be dialed. Dial Modifiers: P : Pulse dial. Only digits 0-9 may be used in pulse dial mode. R : Reverse dial mode. Originates call in answer mode.
Appendix F 101 I n Modem Identification Causes modem to provide information about itself. I0 : Returns product code (for example, “Digi International Modem/Xem”). I1 : Returns 3-digit checksum of ROM. I2 : Checks ROM by calculating and verifying checksum.
T1 Modem Bank 102 N n Select Negotiate Handshake Controls automode enable/disable. N0 : When originating or answering, handshake only at the comm unication rate specified by register S37 and command B n , with no fallback.
Appendix F 103 S n ? Read S Register n Reports the value of S register n as a 3-digit decimal number. n = 0-99 T Enable Tone dialing Instructs the modem to use DTMF tones when dialing. Dialed digits will be tone dialed until a P comma nd or dial modifier is received.
T1 Modem Bank 104 Y n Dummy Command Dummy command for compatibility. Y0 : Returns OK. Y1 : Returns OK. Z n Recall Stored Profile Forces the modem to go on-hook and restore the selected profile. Non-storable parameters are returned to their factory settings.
Appendix F 105 AT& (Ampersand) Commands &B n Autoretrain Defines modem action when it receives a poor signal. &B0 : Hang up on a poor received signal. * &B1 : Retrain on a poor received signal. Hang up if condition persists longer than the threshold set in register S7 .
T1 Modem Bank 106 &G n Guard Tone Operation Determines which guard tone, if any, to transmit while transm itting in the high band (answer mode). Used only in V.22 and V.22 bis mode. * &G0 : No guard tones. &G1 : 550 Hz guard tone. &G2 : 1800 Hz guard tone.
Appendix F 107 &M n Select Sync, Async or AutoSync Mode Options Selects the communication mode. * &M0 : Async mode. &M1 : Sync mode 1. Async off-line and Sync on-line. To switch to on-line comma nd mode, select &D1 and drop DTR. &M2 : Sync mode 2.
T1 Modem Bank 108 &S n Data Set Ready Option Controls the functions of DSR. DSR indicates when the modem is connected to a com munications channel and is ready. Async mode only. If the modem is in Sync mode, DSR is on during handshake and when on- line.
Appendix F 109 &V n View Active Configuration and Stored Profile Displays the active and stored profiles (commands and S register settings), and any stored telephone numbers. The following example illustrates typical &V information for the Digi Modem/Xem.
T1 Modem Bank 110 &X n Sync Transmit Clock Source Determines how the DTE transmit clock is generated while the modem is in synchronous modes. * &X0 : The modem generates the transmit clock and applies it to pin 15 (EIA-232).
Appendix F 111 AT% (Percent) Commands %A n Set Autoreliable Fallback Character Allows the user to specify the character that tells the modem to return (or fall back) from autoreliable (MNP) mode to a normal connection on the answering modem. Result Codes: OK Returned when n = 0-127 (ascii character set).
T1 Modem Bank 112 AT (Backslash) Commands A n Block Size for V.42 Sets the maximum block size during connection. This option forces the modem chip set to transmit smaller blocks of data. The command is typically used for poor quality telephone lines where transm itting smaller blocks reduces retransmission and improves throughput.
Appendix F 113 J n Constant DTE Speed Option * J0 : DCE and DTE rates are independent. J1 : DTE rate adjusts to DCE connection rate after online. Result Codes: OK Returned when n = 0 or 1. ERROR Returned for any other value of n . K n Set Break Control Selects the way in which the modem handles a break signal.
T1 Modem Bank 114 N n Modem Protocol Options Selects the type of data connection the modem can establish. N0 : Normal mode. No protocol, but flow control is allowed. N1 : Direct mode. No protocol and no flow control is allowed. N2 : MNP reliable mode.
Appendix F 115 X n Set XON/XOFF Passthrough Option Valid only if XON/XOFF flow control is enabled, such as with G1 or Q1 ; otherwise, XON/XOFF will not be detected by the modem, and thus will always pass through. * X 0 : Process XON/XOFF per G and Q options; do not pass XON/XOFF to the remote modem or local DTE.
T1 Modem Bank 116 AT- (Dash) Commands -J n Set V.42 Detection Phase Defines whether the originating modem sends a sequence to the answering m odem to determ ine the type of error correction it has enabled. -J0 : Disables the V.42 detection phase. * -J1 : Enables the V.
Appendix F 117 AT" (Quote) Commands "H n V.42bis Compression Control Controls V.42bis data compression over an error correction link. "H0 : Disable V.42bis. "H1 : Enable V.42bis only when transmitting data. "H2 : Enable V.42bis only when receiving data.
T1 Modem Bank 118 Class 1 FAX Commands The Digi Modem/Xem supports FAX com mands conform ing to EIA standard 578. These comm ands are given here with short descriptions; complete descriptions are given in the standard, available from the Electronic Industry Association.
Appendix F 119 Table 9 Supported FAX Transmit/Receive Modulations n Modulation Speed (Bits/Second) 3 V.21 ch. 2 300 24 V.27terbo 2400 48 V.27terbo 4800 72 V.29 7200 73 V.17LT 7200 74 V.17ST 7200 92 V.17terbo 192 LT 19200 93 V.17terbo 192 ST 19200 96 V.
T1 Modem Bank 120 Class 2 FAX Commands +FAA= n FAX Auto Answer Enable Command Syntax: +FAA= <value> 0: Answer as FAX modem of type specified by +FCLASS .
Appendix F 121 +FBOR Data Bit Order Selection. Command syntax: +FBOR= <value> 0: Direct bit order for both Phase C data and Phase B/D data. 1: Reversed bit order for Phase C data and direct bit order for Phase B/D data. 2: Direct bit order for Phase C data and reversed bit order for Phase B/D data.
T1 Modem Bank 122 +FDCC FAX Capability Parameters Command syntax: +FDCC=VR,BR,WD,LN,DF,EC,BF,ST Response syntax: VR,RB,WD,LN,DF,EC,BF,ST Valid Values: VR: Vertical resolution 0: Normal, 98 lpi 1: Fine, 196 lpi BR: Bit rate 0: 2400 bps V.27ter 1: 4800 bps V.
Appendix F 123 +FDCS Current Session Results. Command syntax: +FDCS? Response syntax: VR,BR,WD,LN,DF,EC,BF,ST Valid Values: VR: Vertical resolution 0: Normal, 98 lpi 1: Fine, 196 lpi BR: Bit rate. 0: 2400 bps V.27ter 1: 4800 bps V.27ter 2: 7200 bps V.
T1 Modem Bank 124 +FDFFC Data Compression Format Conversion Command syntax: +FDFFC= <value> 0: Disable mismatch checking. The DTE must check the +FDCS:DF subparameter, and transfer matching data.
Appendix F 125 +FDR Begin or continue Phase C Receive Data. Command syntax: +FDR This command will initiate a transition to Phase C data reception. +FDT Begin Phase C Data Transmission. Command syntax: +FDT This command prefixes Phase C data transmission.
T1 Modem Bank 126 +FMFR Manufacturer’s Identification. Command syntax: +FMFR? Response value: The information text cannot exceed 2048 characters. This command causes the m odem to send one or m ore lines of information text which is used to identify the manufacturer.
Appendix F 127 Class 2 FAX Responses +FCFR Indicate Confirmation to Receive. Syntax: +FCFR Usage: Indicates the reception of an acceptable TCF training burst and valid DCS signal from the remote machine. +FCON Facsimile Connection Response. Syntax: +FCON Usage: Indicates connection with a FAX machine.
T1 Modem Bank 128 S Registers All bit-mapped registers are read-only. The appropriate AT command which controls the relevant bits in the S register should be used to change the value. The factory default values are stored in ROM and are loaded into the active configuration at powerup or by the ATZ n comm and.
Appendix F 129 S Register Definitions S0 Autoanswer Ring Count Sets the number of the rings required before the modem automatically answers a call. Setting this register to zero disables autoanswer mode. Range: 0-255 Default: 000 Units: rings S1 Ring Count The value of S1 is incremented with each ring.
T1 Modem Bank 130 S6 Wait Before Dialing Sets the length of tim e, in seconds, that the modem must wait (pause) after going off-hook before dialing the first digit of the telephone number. The modem always pauses for a minim um of 2 s, even if the value of S6 is less than 2 s.
Appendix F 131 S12 Guard Time Defines the maxim um period, in 2-hundredths of a second, allowed between consecutive asynchronous escape characters (+) for the escape sequence to be considered valid. Range: 0-255 Default: 050 (1 s) Units: 0.02 s S14 Bit-Mapped Options Indicates the status of command options.
T1 Modem Bank 132 S16 Bit-Mapped Option Status Indicates the test in progress status. Default: 000 Bit 0 Local analog loopback 0 local ALB disabled 1 local ALB enabled ( &T1 ) Bit 1 Reserved Bit 2.
Appendix F 133 S18 Modem Test Timer Sets the length of time, in seconds, that the modem conducts a test (comm anded by &T n ) before returning to the command m ode. If this register value is zero, the test will not automatically term inate; the test must be term inated from the command mode by issuing an &T0 or H command.
T1 Modem Bank 134 S21 Bit-Mapped Options Indicates the status of command options. Default: (30h), (048d), (00110000b) Bit 0 Reserved. Bit 1 Reserved Bit 2 CTS behavior ( &R n ) 0 &R0 CTS follo.
Appendix F 135 S22 Bit-Mapped Options Indicates the status of command options. Default: (76h), (118d), (01110110b) Bit 1, 0 Speaker volume ( L n ) 00 L0 is selected 01 L1 is selected 10 L2 is selected.
T1 Modem Bank 136 S23 Bit-Mapped Options Indicates the status of command options. Default: (001), (015d), (00001111b) Bit 0 Grant RDL 0 &T5 is selected 1 &T4 is selected Bit 3, 2, 1 Reserved B.
Appendix F 137 S27 Bit-Mapped Option Indicates the status of command options. Default: (40h), (064d), (01000000b) Bit 3, 1, 0 Synchronous/asynchronous selection ( &Q n , &M n ) 000 &Q0 , &.
T1 Modem Bank 138 S37 Desired DCE Speed Default = 000 0 = Attempt to connect at the last AT speed 3 = Attempt a 300 bits/s connection 5 = Attempt a 1200 bits/s connection 6 = Attempt a 2400 bits/s con.
Appendix F 139 S44 Bit-Mapped Option Status Default = (17h) (023d) (00010111b) Bit 0 V.42bis status 0 disabled 1 enabled Bit 1-2 V.42bis selection ( "H n ) 00 "H0 is selected 01 "H is s.
T1 Modem Bank 140 S51 Data/FAX DTE Flow Control Selection Default = 003 Bit 0-2 ( &K n , Q n ) 000 &K0 , Q0 are selected 001 &K1 , Q1 are selected 010 &K2 , Q2 are selected 011 &K3.
Appendix F 141 S58 BTLZ String Length Default = 032 Range: 6-64 bytes S59 Bit-Mapped MNP Options Default = 001 Bit 0 MNP 5 status ( %C n ) 0 %C0 is selected 1 %C1 is selected S62 DTE Rate Status Defau.
T1 Modem Bank 142 S72 DTE Speed Select During Data Transfer Default = 000 0 last autobaud speed 1 300 bits/s 2 600 bits/s 3 1200 bits/s 4 2400 bits/s 5 4800 bits/s 6 7200 bits/s 7 9600 bits/s 8 12000 .
Appendix F 143 Result Codes The modem connect message is controlled by ATQ , ATV , ATW , ATX , and ATV . Display Format Options If ATQ1 is selected, there will be no connect message at all.
T1 Modem Bank 144 Extended Message Options ATV1 affects only ATW0 and ATW2 commands. If ATW0 , ATV1 , and ATV0 are selected and the DTE rate is 57600 bits/s, then “CONNECT 57600” will be displayed regardless of protocol. If ATW0 , ATV1 , and ATV1 , are selected and the DTE rate is 57600 bits/s, then: a.
Appendix F 145 2 RING The modem sends this result code when incoming ringing is detected on the line. 3 NO CARRIER The modem sends this result code when attempting to establish a call if: 1. Ringback is detected and later ceases but no carrier is detected within the period of time determined by register S7 , or 2.
T1 Modem Bank 146 Negotiation Progress Messages 40 CARRIER 300 The modem returns this result code when either a V.21 or Bell 103 carrier has been detected on the line, and carrier reporting has been enabled. (See W1 .) 42 CARRIER 75/1200 The modem sends this result code when the V.
Appendix F 147 56 CARRIER 24000 The modem sends this result code when the channel carrier in V.34 mode has been detected on the line, and carrier reporting has been enabled. 57 CARRIER 26400 The modem sends this result code when the channel carrier in V.
T1 Modem Bank 148 83 PROTOCOL: MNP 2, 4 This message is sent to the DTE when the modem has connected in the MNP m ode of error correction, and PROTOCOL message reporting has been enabled.
Index 149 Index AT Command Set, 99 Cables Terminal Port, 91 Clear To Send, 44 Configuration EPC/X Host Adapter, 20 Line Card, 58, 61 T1 Modem Bank, 41 Contention Memory addresses, 85 CTS.
T1 Modem Bank 150.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Digi 90031300 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Digi 90031300 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Digi 90031300, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Digi 90031300 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Digi 90031300, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Digi 90031300.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Digi 90031300. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Digi 90031300 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.