8 514 - 230 - 001 REV PR page 1 COMMERCIAL WASHER MODEL T- 1200 VENDED C- SERIES CONTROL OPERATOR’S MANUAL INSTALLATION & OPERATION INSTRUCTIONS Please read t his infor mation and ret ain for r eference. WARNIN G - THIS WASHER IS EQUIPPED WITH DEVICES AND FEATURES RELATING TO ITS SAFE OPERA TION.
8 514 - 230 - 001 REV PR page 2 TABLE OF CONTENTS Page No. Wash er Specifications 2 Mounting Dimensions 3 Installation Instructions 4 Operating Instructions 8 Programming the Washer Control 10 Display.
8 514 - 230 - 001 REV PR page 3.
8 514 - 230 - 001 REV PR page 4 INSTALLATION INSTRUCTIONS All washers must be installed in accordance with all local, state and national building, electrical, plumbing and other codes in effect in the area. WARNING - THESE INSTALLATION AND SERVICING INSTRUCTIONS ARE FOR USE BY QUALIFIED PERSONNEL ONLY.
8 514 - 230 - 001 REV PR page 5 CONCRE TE PEDES TAL MOUN TING Figure 1-1 Figure 1-2 FLOOR OU TLINE Figure 1-3 MACHIN E MOUNTING DETAI L.
8 514 - 230 - 001 REV PR page 6 PLUMBING Water supply hoses are furnished with each machine. The threaded connections on the hoses are ¾ -11 ½ NHT. Separate hot and cold water lines must be provided, maintaining 30 psi to 120 psi (207 kP a to 8 27 kPa) water flow pressure.
8 514 - 230 - 001 REV PR page 7 FUSING REQUIREMENTS: SINGLE- and THREE -PHASE 208-240VAC MODELS - 20 AMP TIME-DELAY (DUAL ELEMENT) FUSE (or equivalent circuit breaker) CONTROLS TRANSFORMER The controls transformer is located inside the control trough and steps a range of 208 to 240 volts down to 115 volts.
8 514 - 230 - 001 REV PR page 8 OPERATING INSTRUCTIONS - STARTING THE WASHER A. Load the clothes into the cylinder and latch the door securely. Be sure clothing does not get caught between the door gasket and tub front when closing the door. Maximum load is 80 pounds clothes, dry weight.
8 514 - 230 - 001 REV PR page 9 EMERGENCY STOP / SAFETY DOOR LOCK This machine is equipped with a Safety Door Lock that locks the door closed from when the cycle is started until the cycle is complete. The door lock prevents opening the door for up to 3 minutes if the power is interrupted during the cycle.
8 514 - 230 - 001 REV PR page 10 PROGRAMMING THE WASHER CONTR OL The washer control can be programmed to prompt the user for alternate vend prices, change washer cycle times, temperatures and many other options. This can be accomplished in two ways: 1.
8 514 - 230 - 001 REV PR page 11 When manual programming mode is entered, the “Start”, “Hot”, “Warm” and “Cold” buttons perform alternate functions.
8 514 - 230 - 001 REV PR page 12 Quick Test Option: When the Quick Test Option is chosen, the washer will begin a shortened wash cycle without the displayed vend price being met. The purpose of this shortened cycle is to test all major components for proper operation.
8 514 - 230 - 001 REV PR page 13 Prices Option: This option allows the user to set values for coin acceptor inputs and to set the vend pric e. It also allows the user to return the values to factory defaults.
8 514 - 230 - 001 REV PR page 14 Cycles Option: This option allows the user to set the bath time and spin time for the “Wash” bath. It also allows the user to set bath time, water temperature and spin time for “Rinse” and “Fin al rinse” baths.
8 514 - 230 - 001 REV PR page 15 3. “Delay Spin” is meant to be used in applications where the amount of drain capacity is limited. In these cases the washer cannot empty the tub in sufficient time to allow for a spin cycle to occur.
8 514 - 230 - 001 REV PR page 16 Plus Cycle Options: The “Plus Cycle” options allow for the user to prompt the customer for varying vend prices based on additional wash baths chosen. In general, the user can program the additional wash baths in a similar manner to what was described in the “Cycles” Options section.
8 514 - 230 - 001 REV PR page 17 “Final Rinse” bath. If the customer does not meet the vend price of the “Extra Rinse” feature, the prompt will time out and the “Extra Rinse” bath will not occur.
8 514 - 230 - 001 REV PR page 18 Settings: The “Settings” options allow for the user to make various programming changes to change how the control operation affects the customer.
8 514 - 230 - 001 REV PR page 19 press the “Enter” button to move to the minutes. Once the hours and minute are both chosen, the “Enter” button must be held down for 3 seconds to confirm that RTC is meant to be reset to the complete entry.
8 514 - 230 - 001 REV PR page 20 Usage Menu: The Usage menu allows for the user to track data about machine usage. See below for detailed information on each sub menu option. 1. “Coin Audit”: The coin audit field shows the accumulation of coin pulses that were sent to the control over each of the left and right coin inputs.
8 514 - 230 - 001 REV PR page 21 The figure below shows the sub menu options for Usage:.
8 514 - 230 - 001 REV PR page 22 Control Menu: The Control menu allows for the user to observe important technical information for the control. No changes can be made at this menu. See below for detailed information on each sub menu. 1. “Serial Number”: This is the control serial number.
8 514 - 230 - 001 REV PR page 23 COIN WASHER DEFAULT CYCLE The following table shows the complete details for the coin washer default cycle. Bath Bath Cycle Time (min.
8 514 - 230 - 001 REV PR page 24 DISPLAYED WASHER FAU LTS Display ed F ault Code Description DOOR LOCK ERROR Door Loc k Error Condition This error is when th e Door Locked signal i s not received within one se cond after the start of the cycle. A fter three attem pts to start the was her.
8 514 - 230 - 001 REV PR page 25 Condition Invalid washer size jump er (harness) configuration. COMM ERROR2 Wrong Wash er Size Jumper Configurati on Delay Immediate (after the wrong size jumper co nfig uration is read) . Wash er size/t ype inp uts are read o nly at power up, before star ting a cycl e, once every 24 hours, and in factory test mode.
8 514 - 230 - 001 REV PR page 26 COMM ERROR5 VFD Communication Fault Condition This error is a dat a error on communications between the controller and the VF drive Delay Delay t ime is 12 se conds. Action Stop the machine and clear the cycle. Keep the door locked until the mach ine has stoppe d mov ing and then unlock the door.
8 514 - 230 - 001 REV PR page 27 Condition This error is when th e dr ive size d oes no t match the washer size. DRIVE ERROR1 Washer si ze/ VFD size mismat ch Delay Immediate.
8 514 - 230 - 001 REV PR page 28 DRIVE OV VFD Over - voltage Fault Condition This error is over - voltage on the VF drive Delay Delay t ime is 35 se conds. Action Stop the machine and clear the cycle. Keep the door locked until the mach ine has stoppe d mov ing and then unlock the door.
8 514 - 230 - 001 REV PR page 29 DRIVE GFI VFD Ground Fault Condition This error is a gr ound fault interrupt ion on the VF drive Delay Delay t ime is 12 se conds. Action Stop the machine and clear the cycle. Keep the door locked until the mach ine has stoppe d mov ing and then unlock the door.
8 514 - 230 - 001 REV PR page 30 SERVICING AND TROUBLESHOOTING CAUTION: Label al l wires prior to disconnecti on when servici ng control s. Wiri ng errors c an cause improp er a nd dangerous operation. Veri fy proper operati on after serv icing. ATTENTION.
8 514 - 230 - 001 REV PR page 31 Door wil l not open Thermoactuator Check to see if the rmoactuator and its mechanism are stuck or binding and not allowing the door lock motor to open. Check to be sure that the locking th ermo actuato r is not receivin g 120V AC du ring the last 1 1/2 minute s of the cycle.
8 514 - 230 - 001 REV PR page 32 Water do es not flush softener compartment. Water Val ve Coil Check coil continuity at terminal s and repl ace if no co ntinuity . Water In let Scr eens Check water in let screens for block age and clean if necess ary.
8 514 - 230 - 001 REV PR page 33 IMPORTANT TRANSIENT VOLTAGE SURGE SUPPRESSORS Like most electrical equipment your new machine can be damaged or have its life shortened by voltage surges due to lightning strikes which are not covered by factory warranty.
8 514 - 230 - 001 REV PR page 34 ACCESSORIES INSTALLATION : (Furnished) QTY. 9990 - 027 - 013 Hose, Water Supply 4 8641 - 242 - 000 Washer, Inlet Hose 4 9565 - 00 3- 001 Strainer, Inlet Hose 8 Contact distributor or Dexter Laundry, Inc. if a steel-mounting base is required.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Dexter T-1200 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Dexter T-1200 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Dexter T-1200, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Dexter T-1200 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Dexter T-1200, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Dexter T-1200.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Dexter T-1200. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Dexter T-1200 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.