2- ENG A08184 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury .
3- ENG A08184 IMPORT ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this pr oduct could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment.
4- ENG A08184 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury .
5- ENG A08184 WARNING: Risk to Breathing WARNING: Risk of Electrical Shock HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
6- ENG A08184 WARNING: Risk of Burns T ouching exposed metal such as the compressor head or outlet tubes, can result in serious burns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation.
7- ENG A08184 Review and underst and all instructio ns and warnings in this manual. Become famil iar with the operation and contr ols of the air compresso r . Keep operati ng area clear of all persons, pets, and obstacle s. Keep childr en away from the air compr essor at all times .
8- ENG A08184 GLOSSAR Y DUTY CYCLE Accessories for this unit are available at the store the unit was purchased. ACCESSORIES Become familiar with these terms before operating the unit. CFM : Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery .
9- ENG A08184 Assemble Wheels It will be necessary to brace or support one side of the outfit when installing the wheels because the compressor will have a tendency to tip. 1. Attach wheels with shoulder bolts and nuts as shown. 2. Tighten securely . NOTE : The outfit will sit level if the wheels are properly installed.
10- ENG A08184 INST ALLA TION GROUNDING INSTRUCTIONS RISK OF ELECTRICAL SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current.
11- ENG A08184 Extension Cords Use extra air hose instead of an extension cord to avoid voltage drop and power loss to the motor , and to prevent overheating.
12- ENG A08184 Description of Operation Become familiar with these controls before operating the unit. On/Auto/Off Switch : T ur n this switch "ON/AUTO" to provide automatic power to the pressur e switch and "OFF" to remove power at the end of each use.
Before Starting Break-in instructions Serious damage may result if the following break-in instructions are not closely followed. This procedur e is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.
14- ENG A08184 How to Start: 1. T urn the On/Auto/Off lever to "ON/AUTO" and allow tank pressur e to build. Motor will stop when tank pressur e reaches "cut-out" pressur e. 2. T urn regulator knob clockwise to increase pressure and stop when desired pressur e is reached.
15- ENG A08184 NOTE: See "Operation" section for the location of controls. T o ensure efficient operation and longer life of the air compressor outfit, a routine maintenance schedule should be prepared and followed.
16- ENG A08184 Air Compressor Pump Intake and Exhaust V alves Once a year have a T rained Service T echnician check the air compressor pump intake and exhaust valves. If it is dirty , replace it with a new filter . On some models,the filter may be removed by using a pair of needle nose pliers or a screwdriver .
17- ENG A08184 8. Apply sealant to the check valve threads. Reinstall the check valve (tur n clockwise). 9. Replace the pressur e release tube. Tighten nuts. 10. Replace the outlet tube and tighten nuts. 11. Perform the Break-in Procedure. See "Break-in Procedure" in the Operation section.
18- ENG A08184 STORAGE Before you store the air compressor , make sure you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary . 2. Set the On/Auto/Off lever to "OFF".
19- ENG A08184 TROUBLESHOOTING Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur . Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressur e.
20- ENG A08184 PROBLEM CAUSE CORRECTION It is normal for "some" pressur e drop to occur . If there is an excessive amount of pressur e drop when the accessory is used, adjust the regulator following the instructions in the "Description of Operation" paragraph in the "Operation Section.
21- ENG A08184 Regulator will not shut off air outlet. Damaged regulator Replace PROBLEM CAUSE CORRECTION Motor will not run. Fuse blown, circuit breaker tripped.
22- ENG A08184 AIR COMPRESSOR DIAGRAM T orque 5-7 ft.-lbs. 5 24 26 27 28 25 9 10 21 15 17 6 10 11 14 18 4 3 T o rque 9-12 ft.-lbs. 2 1 T orque 15-25 ft.
23- ENG A08184 P ARTS LIST Key Part No. Number Description 1 ACG-408 Fastener Assembly (2) 2 AC-0376 Mini Shroud 3 91895680 Screw 1/4-20 x 3/4 (2) 4 ACG-18 Cup, Saddle Mount (2) 5 CAC-60 Shoulder Bolt.
24- ENG A08184 AIR COMPRESSOR PUMP DIAGRAM T orque 51-63 in.-lbs. T o rque 100-120 in.-lbs. T orque 100-120 in.-lbs. T o rque 7-10 ft.-lbs. T o rque 42-48 in.
25- ENG A08184 P ARTS LIST KEY P ART NO. NO. DESCRIPTION 70 SSF-586 Screw 1/4-20 x 3/4 72 AC-0108 Fan 73 SSF-615 Screw 1/4-20 UNC-2A THD 74 Z-AC-0107 Eccentric Bearing Assembly 76 Z-D27268 Motor 77 D2.
26- ENG A08184 A08184 LIMITED W ARRANTY DEL T A MACHINERY warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté DeWalt A08184 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du DeWalt A08184 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation DeWalt A08184, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le DeWalt A08184 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le DeWalt A08184, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du DeWalt A08184.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le DeWalt A08184. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei DeWalt A08184 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.