MODEL NO. F A125 F AC125 MGP-FA125-2A 9/18/99 SAFETY GUIDELINES - DEFINITIONS Information for preventing damage to equipment. This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS .
2 - ENG LIMITED WARRANTY ONE YEAR FROM DA TE OF PURCHASE All merchandise manufactured by DeVilbiss Air Power Company/ExCell Manufacturing is warranted to be free of defects in workmanship and material which occur during the first year from the date of purchase by the original purchaser (initial user).
3 - ENG CONTINUE NEXT P AGE RISK OF BURSTING RISK OF EXPLOSION OR FIRE RISK OF ELECTRICAL SHOCK AIR TANK THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT IN A VIOLENT TANK EXPLOSION: 1. FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK, CAUSING RUST AND THINNING OF THE STEEL TANK.
4 - ENG HAZARD RISK OF ELECTRICAL SHOCK RISK FROM FLYING OBJECTS RISK TO BREATHING RISK FROM MOVING PARTS RISK OF BURNS WHAT CAN HAPPEN REPAIRS ATTEMPTED BY UNQUALIFIED PERSONNEL CAN RESULT IN SERIOUS INJURY OR DEATH BY ELECTROCUTION.
5 - ENG GLOSSAR Y which the motor automatically re-starts is called "cut-in pressure." CUT-OUT PRESSURE: When you turn on your air com- pressor and it begins to run, air pressure in the air tank begins to build. It builds to approximately 125 PSI before the motor automatically shuts off .
6 - ENG DESCRIPTION OF OPERA TION Air Compressor Pump: To compress air, the piston moves up and down in the cylinder. On the downstroke, air is drawn in through the intake valves. The exhaust valves remain closed. On the upstroke of the piston, air is compressed.
7 - ENG Break-in Procedures INST ALLA TION AND BREAK-IN PROCEDURES GROUNDING INSTRUCTIONS Additional Regulators and Controls Since the air tank pressure is usually greater than that which is needed, a regulator is employed to control the air pressure ahead of any individual air driven device.
8 - ENG OPERA TING PROCEDURES 1. Before attaching air hose or accessories, make sure the OFF/AUTO lever is set to “OFF” and the air regulator or shut-off valve is closed. 2. Attach hose and accessories. When you are finished: 6. Set the “OFF/AUTO” lever to “OFF”.
9 - ENG Defective air tank. CORRECTION Excessive tank pressure - safety valve pops off. Pressure switch does not shut off mo- tor when compressor reaches “cut- out” pressure. Move the pressure switch lever to the “OFF” position. If the outfit doesn’t shut off, unplug.
10 - ENG TROUBLESHOOTING GUIDE (Continued) CORRECTION CAUSE Possible defect in safety valve. Knocking Noise Compressor is not supplying enough air to operate accesso- ries. Prolonged excessive use of air. Decrease amount of air usage. Hole in hose. Remove and clean, or replace.
11 - ENG P ARTS LIST AIR HOSE REGULATOR SAFETY VALVE TANK PRESSURE GAUGE PRESSURE SWITCH AIR HOSE OUTLET PRESSURE GAUGE COMPRESSOR ASSEMBLY AIR TANK DRAIN VALVE (Not Shown) CHECK VALVE (Not Shown) ISOLATOR DESCRIPTION PART NUMBER REGULATOR ...........
MODEL NO. F A125 F AC125 OWNERS MANUAL FOR PERMANENTL Y LUBRICA TED AIR COMPRESSOR (For Home Use Only) DeVilbiss Air Power Company • 213 Industrial Drive • Jackson, TN 38301-9615 W ARRANTY This product is covered by the DeVilbiss one year limited warranty.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté DeVilbiss FA125 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du DeVilbiss FA125 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation DeVilbiss FA125, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le DeVilbiss FA125 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le DeVilbiss FA125, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du DeVilbiss FA125.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le DeVilbiss FA125. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei DeVilbiss FA125 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.