For more information, visit www.desatech.com For more information, visit www.desatech.com DIRECT -VENT GAS FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANUAL Save this manual for future reference.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 2 Figure 1 - VDDVF36PN/PP (Peninsula) Dimensions FRONT VIEW 30" (76cm) (Opening) 25" (64c.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 3 3 Figure 2 - VDDVF36STN/STP (See-thru) Dimensions GLOSSAR Y OF TERMS Chase - A boxlike enclosure to protect venting from the elements when the venting run is on the outside of a structure.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 4 WARNING: Installation and repair should be done by a qualified installer/service person. The appliance should be inspected before use, and at least annually thereafter by a qualified service person.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 5 5 PRE-INSTALLATION PREPARATION Clearances Mantel Clearances Framing CLEARANCES Minimum clearances to combustibles are: • Back and Sides of Surround: .
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 6 PRE-INST ALLA TION PREP ARA TION Continued Figure 8 - Rough Opening for Installing Peninsula Fireplace on Platform * As required by design as long as ceiling clearance is maintained.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 7 7 GENERAL VENTING These models are approved for use with Simpson Dura-Vent 6 5 / 8 " direct-vent pipe components and terminations as well as both flex and rigid Vanguard vent components.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 8 Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 9 9 VENTING INSTALLATION Installation Precautions Installation Planning WARNING: Read all instructions completely and thoroughly before attempting installation.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 10 VENTING INSTALLATION Installation Planning (Cont.) Installation For Horizontal Termination NOTICE: Treatment of firestops and construction of the chase may vary from building type to building type.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 11 11 VENTING INSTALLATION Installation For Horizontal Termination (Cont.) WARNING: Do not recess vent termination in to any wall. This will cause a fire hazard.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 12 VENTING INSTALLATION Installation For Horizontal Termination (Cont.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 13 13 VENTING INSTALLATION Installation For Vertical Termination (Cont.) VENTING INST ALLA TION Continued 4. Connect a section of pipe and extend up through the hole.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 14 Figure 27 - Installed Cathedral Ceiling Support Box Nonhardening Mastic under all edges of support box before nailing 4.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 15 15 VENTING INST ALLA TION Continued VENTING INSTALLATION Installation For Vertical Termination (Cont.) High Altitude Installation Parts Lists For Venting Kits And Components V er tical V enting V = 30' max.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 16 PARTS LISTS FOR VENTING KITS AND COMPONENTS (Cont.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 17 17 INSTALLATION Optional Wireless Hand-Held Remote Control (GHRC Series) Installation INST ALLA .
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 18 VENTING INSTALLATION Gas Line Hook-Up INST ALLA TION Continued GAS LINE HOOK-UP WARNING: Gas line hookup should be done by your gas supplier or a qualified service person.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 19 19 INSTALLATION Gas Supply Testing Installing Log Set INST ALLA TION Continued GAS SUPPLY TESTING Note: This section is intended as a guide for qualified service technicians installing gas to the appliance.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 20 WARNING: Improper installation, adjustment, al- teration, service, or maintenance can cause injury or property damage.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 21 21 BURNER FLAME ADJUSTMENT Burner Removal OPERATING GUIDELINES AND MAINTENANCE INSTRUCTIONS CLEANING AND MAINTENANCE Glass Door Panels CAUTION: Before proceeding, make sure the entire unit is cool.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 22 OPERA TING FIREPLACE WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 23 23 9. Push in the control knob all the w ay and hold in. Immedi- ately light the pilot by pr essing the ignitor button until a flame appears one (1) minute after the pilot is lit.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 24 TROUBLESHOOTING OBSERVED PROBLEM Pilot will not light No gas to burner, although wall switch and valve are set to the ON position Frequent pilot outage Burner goes off after a short time POSSIBLE CAUSE 1.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 25 25 TROUBLESHOOTING Continued POSSIBLE CAUSE 1. Ignitor electrode not connected to igni- tor cable 2. Ignitor cable pinched or wet 3. Piezo ignitor nut is loose 4.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 26 OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfir.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 27 27 TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 28 ACCESSORIES TECHNICAL SER VICE You may have further questions about installation, operation, or troubleshooting. If so, contact DESA Internat ional’s Technical Ser- vice Depart ment at 1-866-672-6040.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 29 29 REPLACEMENT P AR TS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 30 GAS CONTROL VALVE Natural - 104496-01 (14389) Propane/LP - 104496-02 (14390) If in need of replacing, have a qualified technician replace it.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 31 31 1. Where will the product be used? ❍ Living/F amily Room ❍ Office/Warehouse ❍ Utility Shed/Outbuilding ❍ Gar age ❍ Bedroom ❍ Bathroom ❍ Other 2.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 32 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 Postage Required T APE T APE.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 33 33 NOTES _______________________________________________________________________________________.
106918-01B For more information, visit www.desatech.com For more information, visit www.desatech.com 34 2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa VDDVF36PN/PP c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa VDDVF36PN/PP - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa VDDVF36PN/PP, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa VDDVF36PN/PP va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa VDDVF36PN/PP, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa VDDVF36PN/PP.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa VDDVF36PN/PP. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa VDDVF36PN/PP ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.