Manuel d'utilisation / d'entretien du produit CGCFTP 14 du fabricant Desa
Aller à la page of 28
Save this manual for future reference. OWNER’S OPERA TION AND INST ALLA TION MANUAL VENT -FREE PROP ANE/LP GAS COMP ACT FIREPLACE Shown with Optional Cabinet Mantel/Hearth Base Accessory CGCFTP 14,0.
2 107036 VENT -FREE PROP ANE/LP GAS COMP ACT FIREPLACE CGCFTP DANGER: Carbon monoxide poisoning may lead to death! SAFETY INFORMA TION Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea.
3 107036 OWNER’S MANUAL PRODUCT IDENTIFICA TION Figure 1 - Vent-Free Gas Compact Fireplace PRODUCT FEA TURES SAFETY PILOT This fireplace has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS/pilot is a required feature for vent-free room fireplaces.
4 107036 VENT -FREE PROP ANE/LP GAS COMP ACT FIREPLACE CGCFTP ASSEMBL Y WARNING: Always have branch support and screen in place before operating fireplace.
5 107036 OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILA TION Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in.
6 107036 VENT -FREE PROP ANE/LP GAS COMP ACT FIREPLACE CGCFTP DETERMINING FRESH-AIR FLOW FOR FIREPLACE LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space.
7 107036 OWNER’S MANUAL Figure 6 - Ventilation Air from Outdoors Shown with Optional Mantel Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic .
8 107036 VENT -FREE PROP ANE/LP GAS COMP ACT FIREPLACE CGCFTP INST ALLA TION Note: Your Comfort Glow fireplace is de- signed to be used in zero clearance installations. Wall or framing material can be placed directly against any exterior surface of your fireplace, except where standoff spacers are integrally attached.
9 107036 OWNER’S MANUAL INST ALLA TION Continued 36 5 / 8 " 25 7 / 8 " 51 3 / 4 " 26 7 / 8 " 1. Frame in rough opening. Use dimensions shown in Figure 9 for the rough opening. If installing in a corner , use dimensions shown in Figure 10 for the rough open- ing.
10 107036 VENT -FREE PROP ANE/LP GAS COMP ACT FIREPLACE CGCFTP 13" 16" 19" 21" 2 1 / 2 " 6" 8" 10" Note: All vertical measurements are from top of fireplace opening to bottom of mantel shelf. All measurements are in inches.
11 107036 OWNER’S MANUAL ASSEMBLING BRASS TRIM (Brass trim shipped with mantel) 1. Remove packaging from three remain- ing pieces of brass trim. 2. Locate two adjusting plates with set screws, and two shims in the hardware packet. 3. Align shim under adjusting plate as shown in Figure 15.
12 107036 VENT -FREE PROP ANE/LP GAS COMP ACT FIREPLACE CGCFTP 4. Carefully disconnect green and white wires at their insulated connectors. 5. In top of the heater cabinet, locate the four mounting holes on the outer cas- ing. Align these four holes with those on the blower bracket assembly .
13 107036 OWNER’S MANUAL 3 2 1 Follow instructions Removing Valve Cover Shield , page 11, then 1. Install a snap bushing found in hard- ware kit into one of the holes found on rear of valve cover shield. The other hole is for a strain relief clamp (not supplied) to secure incoming electrical supply .
14 107036 VENT -FREE PROP ANE/LP GAS COMP ACT FIREPLACE CGCFTP CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect fireplace to gas supply. Follow all local codes. CAUTION: Never connect fire- place directly to the propane/LP supply.
15 107036 OWNER’S MANUAL INST ALLA TION Continued Figure 25 - Removing Log Base Assembly From Fireplace CONNECTING EQUIPMENT SHUTOFF VALVE TO HEATER CONTROL Installation Items Needed • Phillips screwdriver • sealant (resistant to propane/LP gas, not provided) 1.
16 107036 VENT -FREE PROP ANE/LP GAS COMP ACT FIREPLACE CGCFTP ON POSITION OFF POSITION Open Closed Equipment Shutoff Valve Figure 28 - Checking Gas Joints Shown with Optional Mantel Figure 27 - Equip.
17 107036 OWNER’S MANUAL OPERA TING FIREPLACE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life. LIGHTING INSTRUCTIONS 1.
18 107036 VENT -FREE PROP ANE/LP GAS COMP ACT FIREPLACE CGCFTP INSPECTING BURNER Thermocouple Pilot Burner Figure 31 - Correct Pilot Flame Pattern Figure 32 - Incorrect Pilot Flame Pattern Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 31 shows a correct pilot flame pat- tern.
19 107036 OWNER’S MANUAL TROUBLESHOOTING WARNING: Turn off and un- plug fireplace and let cool before servicing. Only a qualified ser- vice person should service and repair fireplace. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot.
20 107036 VENT -FREE PROP ANE/LP GAS COMP ACT FIREPLACE CGCFTP TROUBLESHOOTING Continued OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring duri.
21 107036 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor ’ s phone.
22 107036 VENT -FREE PROP ANE/LP GAS COMP ACT FIREPLACE CGCFTP REPLACEMENT PA R T S Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty. PARTS UNDER WARRANTY Contact authorized dealers of this product.
23 107036 OWNER’S MANUAL P ARTS CENTRALS Master Parts Distributors 1251 Mound Ave. NW Grand Rapids, MI 49504-2672 616-791-0505 1-800-446-1446 Fax: 616-791-8270 www.nbmc.com Washer Equipment Co. 1715 Main Street Kansas City, MO 64108-2195 KS, MO, AR 816-842-3911 www.
24 107036 VENT -FREE PROP ANE/LP GAS COMP ACT FIREPLACE CGCFTP 12 ILLUSTRA TED PA R T S BREAKDOWN CGCFTP 23 29 32 8 14 36 38 37 13 7 8 17 33 11 4 10 4 7 8 30 3 1 2 9 19 6 22 31 21 40 27 39 39 16 15 18.
25 107036 OWNER’S MANUAL P ARTS LIST CGCFTP This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 22 of this manual. KEY CGCF26TP NO. PART NO. DESCRIPTION QTY.
26 107036 VENT -FREE PROP ANE/LP GAS COMP ACT FIREPLACE CGCFTP ACCESSORIES Purchase these fireplace accessories from your local dealer or Parts Central (see page 23) . If they cannot supply these accessories call DESA International’s Sales Department at 1-866-672-6040 for referral information.
27 107036 OWNER’S MANUAL NOTES _______________________________________________________________________________________________ _______________________________________________________________________.
2701 Industrial Drive P.O. Box 90004 Bowling Green, KY 42102-9004 www.desatech.com 107036-01 Rev. C 04/02 LIMITED WARRANTY VENT-FREE PROPANE/LP GAS COMPACT FIREPLACE DESA International warrants this p.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa CGCFTP 14 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa CGCFTP 14 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa CGCFTP 14, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa CGCFTP 14 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa CGCFTP 14, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa CGCFTP 14.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa CGCFTP 14. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa CGCFTP 14 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.