Manuel d'utilisation / d'entretien du produit CDVBP(A) du fabricant Desa
Aller à la page of 36
CAST IRON STOVE AND DIRECT -VENT (FREEST ANDING FIREPLACE HEA TER) BURNER SYSTEM OWNER’S OPERA TION AND INST ALLA TION MANUAL NA TURAL GAS BURNER SYSTEM MODEL CDVBN(A), PROP ANE/LP GAS BURNER SYSTEM MODEL CDVBP(A) REMOTE READY Save this manual for future reference.
2 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) SAFETY INFORMA TION 1. This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases unless a certified kit is used.
3 105501 OWNER’S MANUAL L O H I OFF ON ON OFF AUTO PRODUCT IDENTIFICA TION Install and use stove and burner system with care. Follow all local codes. In the absence to local codes, use the current National Fuel Gas Code ANS Z223.1 , also known as NFPA 54* (USA) or the current CAN/CGA- B149[.
4 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) LOCATION AND SPACE REQUIREMENTS Determine the safest and most efficient loca- tion for your Comfort Glow cast iron stove. Make sure that rafters and wall studs are not in the way of the venting system.
5 105501 OWNER’S MANUAL Pallet Wood Bolted to Bottom of Stove Body STOVE BODY ASSEMBLY 1. Lift off corrugated box enclosing stove body crating. 2. Remove all screws fastening the wood frame enclosure. Spread wood frame open and lift away from plastic-bagged stove body .
6 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) CAST IRON STOVE AND DIRECT -VENT BURNER SYSTEM ASSEMBL Y Continued Figure 12 - Attaching Stove Door Step Bolt Door Hinge Threaded Hole Stove Door Stove Bottom Bolt Shoulder Adjusting Nut Bolt Stop Catch Bolt Door Claw Door Figure 13 - Catch Bolt and Door Claw Orientation 10.
7 105501 OWNER’S MANUAL WARNING: Never touch the blower wheel while in operation. 7. Peel off the backing paper and stick the supplied wiring diagram decal on the inside of rear cover on right side oppo- site control.
8 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) LOCATION OF VENT TERMINATION When locating vent termination, it is impor- tant to observe the minimum clearances shown in Figure 18, page 9. *Check with local codes or with the current CAN/CGA B149[.
9 105501 OWNER’S MANUAL Fixed Closed Openable Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTE.
10 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) WARNING: Read all instruc- tions completely and thoroughly before attempting installation.
11 105501 OWNER’S MANUAL INSTALLATION FOR HORIZONTAL TERMINATION 1. Determine the route your horizontal venting will take. Note: The location of the horizontal vent termination on the exterior wall must meet all local and national building codes and must not be easily blocked or obstructed.
12 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) UP VENTING INST ALLA TION Continued (Framing Detail) 10" (254mm) 10" (254mm) 7 1 / 2 " (190mm) V ent Opening Combustible W all V ent Opening Noncombustible W all Figure 22 - Vent Opening Requirements 3 .
13 105501 OWNER’S MANUAL VENTING INST ALLA TION Continued Figure 26 - Horizontal Termination Configuration for Rigid Venting Figure 27 - Horizontal Termination Configuration for Rigid Venting Using One 90 ° Elbow Horizontal V enting V ertical (V) Horizontal (H) 37" min.
14 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) Flat Ceiling Installation 1. Cut a 10" square hole in the ceiling us- ing the locating hole as a center point.
15 105501 OWNER’S MANUAL VENTING INST ALLA TION Continued Figure 31 - Installing Firestop If area above is not a room, install firestop below framed hole. If area above is a room, install firestop above framed hole. Continued 3. Cut a hole in the roof using the locating hole as a center point.
16 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) V enting with T wo 90 ° Elbows V ertical (V 1 ) Horizontal (H) 5' min. 6' max. 6' min. 12' max. 7' min. 18' max. 8' min. 20' max. Note: V ertical (V 1 ) + V ertical (V 2 ) = 20' max.
17 105501 OWNER’S MANUAL Figure 37 - Vertical Rigid Venting Configuration With No Horizontal Run VENTING INST ALLA TION Continued V er tical V enting V = 40' max. RVKBK Kit Shown Note: Install restrictor into 4" collar of burner system as shown.
18 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) Figure 39 - Gas Connection * The A.G.A. design-certified manual shutoff valve may be supplied with the appliance or you can purchase it from your dealer. CAUTION: Use only new, black iron or steel pipe.
19 105501 OWNER’S MANUAL Pressure Testing Gas Supply Piping System Test Pressures In Excess Of 1/2 PSIG (3.5 kPa) 1 . Disconnect burner system and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 psig (3.
20 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) STOVE AND DIRECT -VENT BURNER SYSTEM INST ALLA TION Continued Test Pressures Equal To or Less Than 1/2 PSIG (3.
21 105501 OWNER’S MANUAL REMOVING/REPLACING GLASS DOOR CAUTION: Do not operate this burner system with a broken glass door panel or without the glass door panel securely in place. For replacement part in- formation see Replacement Parts , page 30. 1.
22 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with freestanding burner system.
23 105501 OWNER’S MANUAL TO TURN OFF GAS TO APPLIANCE 1. Open lower panel. 2a. T urn ON/OFF switch to “OFF”. 2b . If Using Optional Hand-Held Re- mote: Set selector switch in the OFF position to pre vent draining battery . 3. T ur n off all electrical power to the appliance if service is to be perf ormed.
24 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) 1. After lighting, let pilot flame bur n f or about one minute. T urn g as control knob on the control v alve to ON posi- tion. T urn va ri ab le control knob any- where between HI and LO.
25 105501 OWNER’S MANUAL INSPECTING BURNERS Check pilot flame pattern and burner flame patterns often. PILOT ASSEMBLY The pilot assembly is factory preset for the proper flame height. Alterations may have occurred during shipping and handling. Call a qualified service person to readjust the pilot if necessary.
26 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) CLEANING AND MAINTENANCE WARNING: Turn off burner sys- tem and let cool before cleaning. CAUTION: You must keep con- trol areas, burners, and circulat- ing air passageways of burner system and stove clean.
27 105501 OWNER’S MANUAL TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off burner system and let cool before ser- vicing. Only a qualified service person should service and repair burner system or stove.
28 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) OBSERVED PROBLEM Burner does not light after pilot is lit Delayed ignition burner Burner backfiring during combustion Slight smoke or .
29 105501 OWNER’S MANUAL TROUBLESHOOTING Continued WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone.
30 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) SER VICE HINTS When Gas Pressure Is Too Low • pilot will not stay lit • burners will have delayed ignition • burner system will .
31 105501 OWNER’S MANUAL SPECIFICA TIONS CDVBN(A) CDVBP(A) 16,000-22,000 Btu/hr 14,000-20,000 Btu/hr Gas Type Natural Propane/LP Ignition Piezo Piezo Manifold Pressure 3.5" w.c. 10.0" w.c. Minimum Inlet Supply Pressure 4.5" w.c. 11.0" w.
32 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) ILLUSTRA TED PA R T S BREAKDOWN CDVBN(A) CDVBP(A) L O H I P I L O T OFF ON 27 19 20 21 23 29 30 4 25 1 2 4 4 7 8 9 10 11 13 12 31 15 1.
33 105501 OWNER’S MANUAL KEY NO. PART NUMBER DESCRIPTION QTY. 1 105478-02BR Firebox Assembly 1 2 M11084-26 Screw, Hex 2 3 105482-02CK Rear Cover 1 4 M11084-39 Screw, Hex 12 5 103587-02CK Switch Plat.
34 CAST IRON STOVE AND BURNER SYSTEM 105501 CDVBN(A) AND CDVBP(A) ILLUSTRA TED PA R T S BREAKDOWN CISC CISG 1 4 6 4 5-4 5-1 5-2 3 5-3 5-4 2 STOVE CHASSIS.
35 105501 OWNER’S MANUAL P ARTS LIST CISC CISG This list contains replaceable parts used in your stove. When ordering parts, follow the instructions listed under Replacement Parts on page 30 of this manual. * Included In Hardware Kit KEY PART NO. NO.
COMFORT GLOW LIMITED WARRANTY DIRECT-VENT BURNER SYSTEM AND STOVE CHASSIS DESA International warrants this product to be free from defects in materials and components for two (2) years from the date of first purchase, provided that the product has been properly installed, operated and maintained in accordance with all applicable instructions.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa CDVBP(A) c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa CDVBP(A) - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa CDVBP(A), vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa CDVBP(A) va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa CDVBP(A), mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa CDVBP(A).
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa CDVBP(A). Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa CDVBP(A) ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.