Sav e this manual for future reference. For more information, visit www .desatech.com W ARNING: If the information in this manual is not fol- lowed exactly , a fire or explosion may result causing property damage, personal injury or loss of life.
www .desatech.com 1 1 1916-01F 2 W ARNING: Improper installation, adjustment, altera- tion, service or maintenance can cause injury or prop- erty damage. Refer to this manual for correct installation and operational procedures. For assistance or addi- tional information consult a qualified installer , service agency or the gas supplier .
www .desatech.com 1 1 1916-01F 3 INTRODUCTION W ARNI NG : This p rod uc t con- ta ins and /or ge ner ate s ch emi cal s kno wn to the Stat e of Cali for nia to cause ca nce r or birth d efec ts or oth er rep rod uct ive ha rm.
www .desatech.com 1 1 1916-01F 4 SELECTING LOCA TION Continued • Do not locate appliance close to where gasoline or other flammable liquids may be stored. The appliance must be kept clear and free from combustible materials. • Do not use this appliance if any part has been und er water .
www .desatech.com 1 1 1916-01F 5 VENT TERMINA TION CLEARANCES The final position of your fireplace depends on the location of the vent termination in relation to the clearances that must be observed as shown in Figure 5 on page 6. The vent system serves as the “chimney” as well as the combustion air supply (air intake).
www .desatech.com 1 1 1916-01F 6 Fixed Closed Op en a bl e Fixed Closed Openable V V V V V V V V X X V X G G J F B B K N H I A N E L D B M A C B V V A G G B TERMINA TION CAP AIR SUPPL Y INLET GAS METER RESTRICTED AREA (TERMINA TION PROHIBITED) A = clearance above grade, veranda, porch, deck, or balcony [*12 inches (30.
www .desatech.com 1 1 1916-01F 7 INST ALLA TION W ARNING: Read all instruc- tio ns compl etel y and thorou ghl y before attempting installation. Failure to do so could result in serious injury , property dam- age or loss of life.
www .desatech.com 1 1 1916-01F 8 Figure 7 - V ent T ermination (Horizontal) Direct-V ent Pipe CD32M and CD36M-A 4 1 / 4 " Inner and 7 1 / 4 " Outer CD42M-A 5" Inner and 8" Outer W .
www .desatech.com 1 1 1916-01F 9 INST ALLA TION Continued ELECTRICAL HOOKUP AND REMOTE RECEIVER DIAGRAM An out let box wi th two re ce pta cl es (s ee Fi gu re 9) has bee n su pplie d fo r yo ur conv eni en ce an d is loc ate d ins ide o n the lowe r rig ht si de of t he fir epl ac e.
www .desatech.com 1 1 1916-01F 10 In con forma nce w ith l ocal cod es, rou te a 1/2 " NPT gas line towards the appliance coming in from either the left or right side of the fireplace (see Figure 13). Install a sediment trap between the incoming gas line and the gas control box (see Figure 14).
www .desatech.com 1 1 1916-01F 1 1 INST ALLA TION Continued 3. Undo latches located on top and bottom of firebox (see Figure 17). Carefully swing door to the left.
www .desatech.com 1 1 1916-01F 12 5. Place log #5 (small front log) onto the front left part of grate making sure notches fit over prongs of grate (see Figure 22).
www .desatech.com 1 1 1916-01F 13 Lava Rock and Ember Material 1. Fo r al l m ode ls , pl ac e la va ro ck a lon g s ide s a nd fr ont of fir eb ox bo tto m in are as t ha t are vi sib le. It is n ot nec ess ar y to u se all la va r oc k prov ide d. NOTICE: Do not put lava rock on or under burner .
www .desatech.com 1 1 1916-01F 14 If adjustment is necessary , you can restore the proper flame setting by loosening the air shutter screw and rotating the air shutter until proper setting is achieved (see Figure 31).
www .desatech.com 1 1 1916-01F 15 D. Do no t us e thi s ap pl ian ce if an y par t ha s bee n under water . Immedia tely call a qualifie d s er vi ce te ch ni ci an to in sp e c t t h e a pp li an ce an d to r epl ace an y p art o f the co ntr ol sy ste m a nd an y g as con tr ol wh ich ha s b een un der w ate r .
www .desatech.com 1 1 1916-01F 16 Figure 34 - Converting Pilot Pilot Hood Pilot Orifice Barrel Clip 5/32" Allen Wrench Pilot Bracket 6. Lo cat e ai r sh utt er at en d of bur ner man ifo ld (e nd of tu be bu rne r for CD 42M se ri es ).
www .desatech.com 1 1 1916-01F 17 TROUBLESHOO TING W ARNING: T urn off heater and let cool before servicing. Only a qualified service person should service and repair heater . W ARNING: T urn off heater and let cool before servicing. Only a qualified service person should service and repair heater .
www .desatech.com 1 1 1916-01F 18 6 7 19 18 10 12 23 24 34 2 1 1 17 8 21-2 21-6 21-4 21-5 21-3 21-1 1 13 9 16 3 14 4 20 15 5 15 42 40 35 36 22 37 39 38 25 41 26 30 27 28 29 33 31 32 ILL USTRA TED P AR.
www .desatech.com 1 1 1916-01F 19 KEY P ART NUMBER NO. CD32M CD36M-A DESCRIPTION QTY . 1 ** ** Firebox Assembly 1 2 ** ** Face Weldment 1 3 108892-01 108010-01 Door Assembly 1 4 108903-01 10801 1-01 T.
www .desatech.com 1 1 1916-01F 20 ILL USTRA TED P ARTS BREAKDOWN MODEL CD42M-A 37 23 41 42 38 22 39 32 31 33 28 26 25 29 24 34 35 40 36 30 27 28 6 7 19 18 10 12 2 1 1 17 8 20 1 4 13 16 3 14 15 5 15 9 .
www .desatech.com 1 1 1916-01F 21 KEY NO. P ART NUMBER DESCRIPTION QT Y . 1 ** Firebox Assembly 1 2 ** Face Weldment 1 3 108328-01 Door Assembly 1 4 108331-01 T op Panel Assembly Louver 1 5 108331-03 .
www .desatech.com 1 1 1916-01F 22 SPECIFICA TIONS CD32M CD36M-A CD42M-A Gas Rate (Natural) 12,000/ 18,000 Btu/hr 15,000/ 22,000 Btu/hr 25,000/ 35,000 Btu/hr Gas Rate (Propane/LP) 11,000/ 17,000 Btu/hr 14,000/ 20,000 Btu/hr 23,000/ 33,000 Btu/hr Ignition Piezo Piezo Piezo Natural Gas Manifold Pressure 3.
www .desatech.com 1 1 1916-01F 23 ACCESSOR Y AND REPLACEMENT P ARTS P/N 104506-20 P/N 104506-20 P/N 1 10994-01 (CD36M-A SERIES) P/N 108328-01 (CD42M-A) USED ON BLOWER ONL Y P/N 00710 (OPTIONAL) REMOTE.
2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com NOT A UPC 1 1 1916-01 Rev . F 04/05 111916 01.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa CD36M-A1 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa CD36M-A1 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa CD36M-A1, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa CD36M-A1 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa CD36M-A1, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa CD36M-A1.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa CD36M-A1. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa CD36M-A1 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.