Manuel d'utilisation / d'entretien du produit (V)T36EPA du fabricant Desa
Aller à la page of 40
For more information, visit www .desatech.com DIRECT -VENT FIREPLACE OWNER’S OPERA TION AND INST ALLA TION MANU AL NA TURAL GAS “TUDOR” MODEL (V)T36ENA SERIES PROP ANE/LP GAS “TUDOR” MODEL (.
www .desatech.com 1 1 1251-01E 2 SAFETY INFORMA TION T ABLE OF CONTENTS Safety Information ............................................... 2 Local Codes......................................................... 4 Product Identication ...............
www .desatech.com 1 1 1251-01E 3 SAFETY INFORMA TION Continued This replace must be installed by a qualied (cer - tied or licensed) service person. It has a sealed gas combustion chamber that uses a coaxial pipe (pipe within a pipe and having the same center) venting system.
www .desatech.com 1 1 1251-01E 4 SAFETY INFORMA TION Continued 2. If you smell gas • shut off gas supply • do not try to light any appliance • do not touch any electrica l switch; do not use any phone in your building • immediately call your gas supplier from a neighbor ’ s phone.
www .desatech.com 1 1 1251-01E 5 Figure 2 - Common Fireplace Locations Flush with a wall Through exterior wall enclosed in a chase Corner installation • The blower requires electricity if installed and if you plan to install the blower at a later date, do not forget to wire the outlet at the bottom of the replace when framing.
www .desatech.com 1 1 1251-01E 6 PRE-INST ALLA TION PREP ARA TION Continued Figure 4 - Framing Clearances for Installation Against an Exterior Wall Figure 5 - Framing Clearances for Corner Installation C B A D E F G T op of Louver Opening 3 2 1 4 5 6 7 Wall Ref.
www .desatech.com 1 1 1251-01E 7 Figure 7 - Minimum Clearances for T ermination Cap LOCA TION OF TERMINA TION CAP Fixed Closed Op en ab le Fixed Closed V V V V V V V V X X V X G G J F B B K N H I A N .
www .desatech.com 1 1 1251-01E 8 VENT ING INST ALLA TION INSTRUCTIONS NOTICE: Read these instruc- .
www .desatech.com 1 1 1251-01E 9 INST ALLA TION PLANNING There are two basic types of direct-vent in - stallation: • Horizontal T ermination • V ertical T ermination Horizontal T ermination Installation IMPORTANT : Horizontal square terminations require only inner portion of wall restop.
www .desatech.com 1 1 1251-01E 10 VENTING INST ALLA TION INSTRUCTIONS Continued W ARNING: Do not recess 6.
www .desatech.com 1 1 1251-01E 1 1 VENTING INST ALLA TION INSTRUCTIONS Continued Figure 13 - T ypical Horizontal T ermination Cap Mounting with Additional Siding Standoff Installed Siding Standoff Scr.
www .desatech.com 1 1 1251-01E 12 CORN ER AND AL TERNA TE INST ALL A TIO N Recommended Applications: • Corner ground oor installation • G ro un d o or in st a l la ti on w he re pi p e v en.
www .desatech.com 1 1 1251-01E 13 VENTING INST ALLA TION INSTRUCTIONS Continued Horizontal (H 1 Horizontal (H 1 Horizontal (H 2 5' min.
www .desatech.com 1 1 1251-01E 14 INST ALLA TION FOR VERTICAL TERMINA TION Note: V ertical restrictor must be installed in all vertical installations. 1.
www .desatech.com 1 1 1251-01E 15 5. Pla ce the ash in g o ver t he pi pe sec tio n( s) extendin g through the roof. Secure the base of the ashing to the roof and framing with roof - ing nails. Be sure roong materi al overlap s the top edge of the ashing as shown in Figure 19, page 14.
www .desatech.com 1 1 1251-01E 16 VENTING INST ALLA TION INSTRUCTIONS Continued Note : Install restrictor into inner collar of replace as shown. V ertical (V 1 5' min.
www .desatech.com 1 1 1251-01E 17 AND COMPONENTS .
www .desatech.com 1 1 1251-01E 18 FIREPLACE INST ALLA TION Use proper gas type for replace unit you are installing.
www .desatech.com 1 1 1251-01E 19 FIREPLACE INST ALLA TION Continued Figure 27 - Location of Wiring Diagram Decal (Model May V ary from Illustration) Wiring Diagram Decal 12" in Front of Burner 9. Check to make sure power cord is completely clear of blower wheel and there are no other foreign objects in blower wheel.
www .desatech.com 1 1 1251-01E 20 1 1. Peel off backing paper and stick supplied wiring diagram decal on rebox bottom ap - proxima tely 12" in front of blower (see Figure 27, page 19).
www .desatech.com 1 1 1251-01E 21 FIREPLACE INST ALLA TION Continued Figure 31 - Gas Connection CSA Design-Certied Equipment Shutoff V alve with 1/8" NPT T ap* 3" Minimum Approved Flexible Gas Line Cap Pipe Nipple T ee Joint Sediment T rap/Drip Leg Natural - From Gas Meter (5.
www .desatech.com 1 1 1251-01E 22 PRESSURE TESTING GAS SUPPL Y PIPING SYSTEM T est Pressures In Excess Of 1/2 PSIG 1. Dis conne ct rep lac e and i ts indiv idual equ ip - ment shutoff valve from gas supply piping sy st em .
www .desatech.com 1 1 1251-01E 23 REMOVING/REPLACING GLASS DOOR .
www .desatech.com 1 1 1251-01E 24 .
www .desatech.com 1 1 1251-01E 25 4. Place log #4 (right log) onto pin on right side of front log as shown in Figure 43. 5. Pl ace lo g #5 (base log) onto front left part of grate making sure notches t over prongs of grate. See Figure 44. 6. Place log #6 (left log) onto two pins on left side of back and front log.
www .desatech.com 1 1 1251-01E 26 FIREPLACE INST ALLA TION Continued Ember Material Figure 45 - Placing Ember Material on Burner 8. Pull ember material apart into pieces no larg er than a dime.
www .desatech.com 1 1 1251-01E 27 STEP DOWN TRANSFORMER PV GND PV/MV TR MV TH IGN EV2 INCOMING MAIN GAS SUPPL Y EV1 GAS LINE TO BURNER 24V AC 120V AC INCOMING 120V AC (FUSE BOX OR BREAKER) OFF ON WALL SWITCH (NOT SUPPLIED) GREEN BLACK WHITE 120v , 60Hz, 0.
www .desatech.com 1 1 1251-01E 28 5. T u rn eq ui pme nt shu to ff val ve clo ck wis e to the OFF position (see Figure 48). Do not force. 6. W ait ve (5) minutes to clear out any gas. Then smell for gas, including near the oor .
www .desatech.com 1 1 1251-01E 29 OPERA TING FIREPLACE Continued TO TURN OFF GAS TO APPLIANCE 1. T urnoffthewallswitch. 2. T urn off all electric power to the appliance if service is to be performed. 3. Open lower louver panel. 4. T u rn eq ui pme nt shu to ff val ve clo ck wis e to OFF .
www .desatech.com 1 1 1251-01E 30 CLEANING AND MAINTENANCE .
www .desatech.com 1 1 1251-01E 31 TROUBLESHOO TING .
www .desatech.com 1 1 1251-01E 32 Pilot will not stay lit No gas to burner, although wall switch and valve are set to the ON position Frequent pilot ou.
www .desatech.com 1 1 1251-01E 33 Glass soots Remote does not function Dark residue on logs or inside of replace 1. Flame impingement on logs 2 . Debris around burner air mixer 1.
www .desatech.com 1 1 1251-01E 34 ILL USTRA TED P ARTS BREAKDOWN .
www .desatech.com 1 1 1251-01E 35 P ARTS LIST This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 38 of this manual.
www .desatech.com 1 1 1251-01E 36 ILL USTRA TED P ARTS BREAKDOWN .
www .desatech.com 1 1 1251-01E 37 P ARTS LIST This list contains replaceable parts used in your replace. When ordering parts, follow the instructions listed under Replacement Parts on page 38 of this manual.
www .desatech.com 1 1 1251-01E 38 REPLACEMENT P ARTS Note: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty .
www .desatech.com 1 1 1251-01E 39 ACCESSORIES NOTICE: All accessories may Pu rch ase th ese rep lace acce ss or ies from your loca l re tai ler .
2701 Industrial Drive P .O. Box 90004 Bowling Green, KY 42102-9004 www .desatech.com NOT A UPC 1 1 1251-01 Rev . E 03/06 WARRANTY INFORMA TION KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Desa (V)T36EPA c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Desa (V)T36EPA - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Desa (V)T36EPA, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Desa (V)T36EPA va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Desa (V)T36EPA, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Desa (V)T36EPA.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Desa (V)T36EPA. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Desa (V)T36EPA ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.