OWNERS MANUAL OWNERS MANUAL OWNERS MANUAL OWNERS MANUAL OWNERS MANUAL ASSEMBLY CALIBRATION OPERATION REPLACEMENT PARTS READ complete manual CAREFULLY BEFORE attempting operation.
Thank you for purchasing a Demco boom. We feel you have made a wise choice and hope you are completely satisfied with your new flotation boom. Your new Demco boom features the newest and most up-to-date design of a boom it's type currently marketed.
Normal sprayer frame, without Height Adjuster. (Shown Above) 1. Mount the Boom Carrier Center Section (#1) to the Mounting Angles (#2) on the back of the sprayer frame using four 3/8" x 2-1/2" square U-bolts (#3) and eight 3/8" nylon locknuts (#4).
MOUNTING THE BOOM CENTER SECTION TO HYDRAULIC HEIGHT ADJUST 7 4 3 15 15 14 28 16 15 5 4 8 2 2 6 2 2 6 5 11 12 5 3 3 3 5 5 3 2 16 15 16 15 17 14 5 3 5 3 1 25 24 23 22 21 20 20 19 13 26 26 13 2 18 18 27 15 16 29 2 18 11 5 5 2 16 16 3 5 17 3 5 17 3 5 R E F .
MOUNTING THE BOOM CENTER SECTION TO MANUAL HEIGHT ADJUST 2 2 3 5 5 5 5 5 3 3 3 6 7 9 11 13 15 16 16 17 17 18 2 19 24 24 29 30 5 4 9 23 9 2 23 27 26 25 1 3 5 3 3 5 16 14 12 10 6 2 19 16 17 17 19 7 3 2 17 16 5 5 31 9 25 26 27 2 20 5 22 3 2 4 5 3 18 17 16 15 3 5 18 8 28 5 5 29 24 (DFBHA OPTION) 8 21 27 25 26 R E F .
CENTER SECTION BOOM CARRIER BREAKDOWN 5 15 19 21 16 16 17 14 10 12 8 6 10 5 5 2 20 19 22 21 13 9 23 20 30 Note: This bracket must be 5" off center in either direction. ASSEMBL Y INSTRUCTIONS 1. Begin by referring to the boom carrier (#1) mounting to the sprayer frame (page 1) or mounting to the height adjust (pages 2 & 3).
LEFT INNER WING P ARTS BREAKDOWN 1. Attach the upper offset linkage (#6) to center section (#1) using one 1/2" x 2" bolt (#7), bushing (#8) and one 1/2" locknut (#9). 2. Next attach the lower linkage bracket (#10) to the upper offset linkage (#6) using one 1/2" x 2" bolts (#7) and one 1/2" locknut (#9).
RIGHT INNER WING P ARTS BREAKDOWN ASSEMBL Y INSTRUCTIONS 1. Attach the upper offset linkage (#6) to center section (#1) using one 1/2" x 1-3/4" bolt (#7), bushing (#8) and one 1/2" locknut (#9).
R E F . PART N O. NO. QTY. DESCRIPTION RIGHT AND LEFT OUTER WING P ARTS BREAKDOWN Page 7 Please order replacement parts by PART NO. and DESCRIPTION. 1. 03322 1 Left Inner Wing 2. 03323 1 Right Inner Wing 3. 03328 2 Right and Left Outer Wing 4. 03326 2 Breakaway Pin 5.
TIP PLACEMENT 1. Marking location of boom clamps: Mark the clamp locations by starting at the center of the center boom section. From this mark, locate 20 inch spaces to both ends of the boom. 2. Fasten preassembled boom lines: Fasten the boom clamps (#3) on the boom so the sprayer tip will be on the back side of the boom.
ADJUSTMENT PROCEDURES After the boom is completely assembled and before attempting to fold the boom for the first time, the boom should be adjusted so it lays straight both horizontally and vertically. There are several ad- justment points built into the boom for this purpose.
ADJUSTMENTS FOR FOLDING AND STORAGE 4. Finally unlock the latch between the center section and inner right wing. (4th fold) Fold the inner right wing and outer right wing back and around to fold to the rear of the center section and into the storage bracket and lock in place with pin.
RIGHT WING MAINTENANCE AND LUBRICA TION LEFT WING TWO GREASE ZERKS FIVE GREASE ZERKS Y our Flotation Boom is designed to require only occasional light maintenance. Atten- tion to the following procedures will signifi- cantly prolong the useful life of your boom.
7 2 1 3. 05619 2 Pin (1/2" x 3" lg.) 4. 02384 4 Machine Washer (1/2" ID x 14 GA.) 5. 00185 2 5/32" x 1 Cotter Pin 6. 05564 2 Wheel Fork 7. 05328 2 1/2" x 3" lg. Ball Lock Hitch Pin 8. 05566 2 Wing Mounting Plate 9. 02802 12 5/16"-18UNC Nylon Insert Locknut 10.
XR8001VS X 20 .07 5.3 4.3 2.8 2.2 25 .08 5.9 4.7 3.1 2.4 30 .09 6.4 5.1 3.4 2.6 40 .10 7.4 6.0 4.0 3.0 XR80015VS X 20 .11 7.8 6.3 4.3 3.2 25 .12 8.8 7.1 4.7 3.6 30 .13 9.7 7.7 5.2 3.9 40 .15 11.1 8.9 6.0 4.5 XR8002VS X 20 .14 10.5 8.4 5.6 4.2 25 .16 11.
SAFETY FIRST SPRA YER CHECK LIST Down time in the field caused by breakdowns is costly and time consuming. Many breakdowns can be eliminated by periodic equipment maintenance. By spending time run- ning over this checklist before seasonal spraying application time and following proper af- ter season care, you can save time and money later on.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Demco AB20001 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Demco AB20001 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Demco AB20001, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Demco AB20001 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Demco AB20001, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Demco AB20001.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Demco AB20001. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Demco AB20001 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.