FEATURES High efficiency: 89% @ 5V/ 15A Size: 58.4mm x 22.8mm x 9.2mm (2.30”x0.90”x0.36”) Industry standard pin out 18~75V extremely wide 4:1 input r ange Fixed frequency ope.
TECHNICAL SPECIFICA TIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal V out unless otherw ise noted.) PA R A M E T E R NOTES and CONDITIONS E36SR05015 (St andard) Min.
ELECTRICAL CHARACTERISTICS CUR VES Figure 1: Efficiency vs. load current for minimum, nominal, and maximum in put voltage at 25°C. DS_E36SR05015_010 42008 3 Figure 2: Power dissipation vs. load current for min imum, nominal, and max i mum input voltage at 25°C.
ELECTRICAL CHARACTERISTICS CUR VES Figure 4: T urn-on trans ient at full rated load current (CC mode) (5ms/div). Vin=48V .T op T rac e: V out, 2V/div; Bottom T race: ON/OFF input, 5V/div . Figure 5: T urn-on transient at zero load current (5ms/ div). Vin=48V .
ELECTRICAL CHARACTERISTICS CUR VES Figure 8: Output voltage response to step-change in load current (50%-25% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF , tantalum cap acitor and 1 µF ceramic cap acitor. T op T race: Vout (100mV/div , 200us/div), Bottom T race: I out (5A/div).
ELECTRICAL CHARACTERISTICS CUR VES Figure 12: Input reflected ripple current, i s , through a 12µH source inductor at 48Vin and 15A output current (20 mA/ div , 2us/div). Strip Copper Vo(-) Vo(+) 10u 1u SCOPE RESISTIV E LOAD Figure 13: Output voltage noise and ripple measur ement test setup.
The input source must be insulated f rom the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. If the metal baseplate is grounded , one Vi pin and one Vo pin shall also be grounded.
DS_E36SR05015_010 42008 8 FEA TURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-curre nt protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modul es will automatically shut down (hiccup mode).
FEA TURES DESCRIPTIONS (CON.) Output V oltage Adjustment (TRIM) To increase or decrea se the output voltage set poin t, the modules may be connected wit h an external resistor betwee n the TRIM pin and either the SENSE(+) or SENSE(-). The TRIM pin should be left open if this feature is not used.
DS_E36SR05015_010 42008 10 THERMAL CONSIDERA TIONS Thermal management is an important part of the syst em design. To ensure p roper, reliable operation, sufficie nt cooling of the power mod ule is needed over the entire temperature range of the modul e.
P I C K A N D P L A C E L O C A T I O N S U R F A C E - M O U N T T A P E & R E E L RECOMMENDED P AD LA YOUT (SMD) DS_E36SR05015_010 42008 11.
LEADED (Sn/Pb) PROCESS RECOMMEND TEMP . PROFILE T ime ( sec. ) Pre-h eat tem p. 140~180 ° C 60~120 sec. Peak tem p. 210~230 ° C 5sec . Ramp-up te mp. 0.5~3.0 ° C /sec . T emperature ( ° C ) 50 100 150 200 250 300 60 0 120 180 240 2nd Ramp-up temp.
MECHANICAL DRA WING Surface-mount module Through-hole module Pin No. Name Function 1 2 3 4 5 6 7 8 +Vin ON/OFF -Vin -V out -SENSE TRIM +SENSE +V out Positive input voltage Remote ON/OFF Negative input.
MECHANICAL DRA WING (WITH HEA TSPREADER) THROUGH-HOLE MODULE DS_E36SR05015_010 42008 14.
DS_E36SR05015_010 42008 15 P ART NUMBERING SYSTEM E 36 S R 050 15 N R F A T ype of Product Input V o ltage Number of Output s Product Series Output V o ltage Output Current ON/OFF Logic Pin Length/T ype Option Code E- Eighth Brick 36-18~75V S- Single R- Regular 050- 5.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Delta Electronics Series E36SR c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Delta Electronics Series E36SR - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Delta Electronics Series E36SR, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Delta Electronics Series E36SR va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Delta Electronics Series E36SR, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Delta Electronics Series E36SR.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Delta Electronics Series E36SR. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Delta Electronics Series E36SR ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.