(2.30” x 0.90” x 0.39”) SMD and Through-hole versions Industry standard pin out 2:1 input range Fixed frequency operation Input UVLO, Output OTP , OCP , OVP Basic insulat.
DS_E24SR05012_010 32008 2 TECHNICAL SPECIFICA TIONS (T A =25°C, airflow rate=300 LFM, V in = 24 Vdc, nominal V out unless otherw ise noted.) PA R A M E T E R NOTES and CONDITIONS E24SR05012 (St andard) Min.
DS_E24SR05012_010 32008 3 ELECTRICAL CHARACTERISTICS CUR VES 80 82 84 86 88 90 92 24 68 1 0 1 2 Output C ur re nt ( A ) E ff i ci en cy (%) 1. 0 2. 0 3. 0 4. 0 5. 0 6. 0 7. 0 2468 1 0 O utput C ur r ent ( A ) L o ss (W ) 18Vin 1 2 Figure 1: Ef ficiency vs.
DS_E24SR05012_010 32008 4 ELECTRICAL CHARACTERISTICS CUR VES For Negative Remote On/Off Logic Figure 4: T urn-on transi ent at full rated load current (resi stive load) (2 ms/div). Vin=24V . T op T race: V out, 2.0V/div; Bottom T race: ON/OFF input, 10V/div Figure 5: T urn-on trans ient at zero load current (2 ms/ div).
DS_E24SR05012_010 32008 5 ELECTRICAL CHARACTERISTICS CUR VES Figure 8: Output voltage response to step-change in load current (75%-50%-75% of Io, max; di/dt = 0.1A/µs). Load cap: 10µF t antalum capacitor and 1µF ceramic capacitor . 0 T op T race: Vout (100mV/div , 200us/div ) , Bottom T r ace: Iout (5 A /div).
DS_E24SR05012_010 32008 6 ELECTRICAL CHARACTERISTICS CUR VES Strip Copper Vo(-) Vo(+) 10u 1u SCOPE RESISTIV E LOAD Figure 12: Input reflected ripple current, i s , through a 12µH source inductor at nominal input voltage and rated loa d current (20 mA/div , 2us/div) Figure 13: Output voltage noise and ripple measur ement test setup 0.
DS_E24SR05012_010 32008 7 The input source must be insulated from the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. If the metal baseplate is grounded , one Vi pin and one Vo pin shall also be grounded.
DS_E24SR05012_010 32008 8 Vi(-) ON/OFF Vi(+) Vo(-) Trim Vo(+) Sense(-) Sense(-) Vi(-) ON/OFF Vi(+) Vo(-) Trim Vo(+) Sense(-) Sense(-) Figure 16: Remote on/off implementation Remote Sense Remote sense compen sates for voltage dro ps on the output by sensing the actual output volt age at the point of load.
DS_E24SR05012_010 32008 9 FEA TURES DESCRIPTIONS (CON.) Output V oltage Adjustment (TRIM) To increase or decrea se the output voltage set poin t, connect an external re sistor between the TRIM pin and either the SENSE(+) or SENSE(-). The TRIM pin should be left open if this feature is not used.
DS_E24SR05012_010 32008 10 THERMAL CONSIDERA TIONS Thermal management is an important part of the syst em design. To ensure p roper, reliable operation, sufficie nt cooling of the power mod ule is needed over the entire temperature range of the modul e.
DS_E24SR05012_010 32008 11 P I C K A N D P L A C E L O C A T I O N S U R F A C E - MOUNT T APE & REEL RECOMMENDED P AD LA YOUT (SMD).
DS_E24SR05012_010 32008 12 LEADED (Sn/Pb) PROCESS RECOMMEND TEMP . PROFILE T ime ( sec. ) Pre-h eat tem p. 140~180 ° C 60~120 sec. Peak tem p. 210~230 ° C 5sec . Ramp-up te mp. 0.5~3.0 ° C /sec . T emperature ( ° C ) 50 100 150 200 250 300 60 0 120 180 240 2nd Ramp-up temp.
DS_E24SR05012_010 32008 13 MECHANICAL DRA WING Surface-mount module Through-hole module Pin No. Name Function 1 -Vin Negative input voltage Remote ON/OFF Positive input voltage Positive output voltage.
DS_E24SR05012_010 32008 14 P ART NUMBERING SYSTEM E 24 S R 050 12 N R F A T ype of Product Input V oltage Number of Output s Product Series Output V oltage Output Current ON/OFF Logic Pin Length/T ype Option Code E - Eighth Brick 24V S - Single R - Regular 050 - 5.
DS_E24SR05012_010 32008 15 at any time, without notice ..
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Delta Electronics Delphi Series E24SR c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Delta Electronics Delphi Series E24SR - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Delta Electronics Delphi Series E24SR, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Delta Electronics Delphi Series E24SR va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Delta Electronics Delphi Series E24SR, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Delta Electronics Delphi Series E24SR.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Delta Electronics Delphi Series E24SR. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Delta Electronics Delphi Series E24SR ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.