Operating Instructions & Parts Manual Dayton Pr opane Construction Heater Description Dayton Model 4E769B heater is a 35,000 BTU/Hr construction heater. This heater uses propane gas for combustion and electricity to run the motor. It is primarily intended for temporary heating of buildings under construction, alteration, or repair.
Dayton Operating Instructions and Parts Manual 2 Dayton Pr opane Construction Heater ® 4E769B General Safety Information Carbon monoxide poisoning may lead to death! Some people are mor e affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea.
Dayton Operating Instructions and Parts Manual 3 Model 4E769B Version B - For Reduction G016.J ® Specifications ELECTRICAL SPECIFICA TIONS Electrical Input Amperage 120 V olt/60Hertz 2 General Safety.
Dayton Operating Instructions and Parts Manual 4 Dayton Pr opane Construction Heater ® 4E769B Product Identification Figure 2 – Model 4E769B Shell Handle Motor Power Cord Hot Air Outlet (Front) Fan.
Dayton Operating Instructions and Parts Manual 5 Model 4E769B Version B - For Reduction G016.J ® A verage T emperature Number of T anks ( o F) at T ank Location (100 pound) 40 ° 1 32 ° 1 20 ° 1 10 ° 1 0 ° 1 -10 ° 2 -20 ° 2 Pr opane Supply Propane gas and propane tank(s) must to provided by the customer .
Dayton Operating Instructions and Parts Manual 6 Dayton Pr opane Construction Heater ® 4E769B Installation Review and understand the warnings in the General Safety Infor - mation Section. They are needed to safely operate this heater . Follow all local codes when using this heater .
Dayton Operating Instructions and Parts Manual 7 Model 4E769B Version B - For Reduction G016.J ® Operation (Continued) NOTE : If not opened slowly , excess-flow check valve on propane tank will stop gas flow . If this happens, close propane supply valve and open again slowly .
Dayton Operating Instructions and Parts Manual 8 Dayton Pr opane Construction Heater ® 4E769B Figure 11 - Removing Motor and Fan Guard from Heater Maintenance (Continued) SERVICE PROCEDURES Never attempt to service heater while it is connected to propane supply , operating, or hot.
Dayton Operating Instructions and Parts Manual 9 Model 4E769B Version B - For Reduction G016.J ® Ignitor Ignitor Mounting Screw Rear Head Figure 15 - Removing Ignitor Mounting Screw and Ignitor 7. Set gap between ignitor electrode and target plate to .
Dayton Operating Instructions and Parts Manual 10 Dayton Pr opane Construction Heater ® 4E769B 4E769B For Replacement Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide follow.
Dayton Operating Instructions and Parts Manual 11 Model 4E769B Version B - For Reduction G016.J ® Dayton Operating Instructions and Parts Manual 4E769B Replacement Parts List Reference Number Description Part No.
Dayton Operating Instructions and Parts Manual 12 Dayton Pr opane Construction Heater ® 4E769B Never attempt to service heater while it is connected to propane supply , operating, or hot. Severe burns and electrical shock can occur . T roubleshooting Chart Symptom Possible Cause(s) Corrective Action 1.
Dayton Operating Instructions and Parts Manual 13 Model 4E769B Version B - For Reduction G016.J ® 4E769B Description Part No. 10' Rubber Hose with Brass Fitting LP A1020 U.L. listed. 15' Rubber Hose with Brass Fitting LP A1030 U.L. listed. Propane Gas Regulator LP A2110 U.
Dayton Operating Instructions and Parts Manual 14 Dayton Pr opane Construction Heater ® 4E769B Notes __________________________________________________________________________________________________.
Dayton Operating Instructions and Parts Manual 15 Model 4E769B Version B - For Reduction G016.J ® 4E769B Notes ________________________________________________________________________________________.
Dayton Operating Instructions and Parts Manual 16 Dayton Pr opane Construction Heater ® 4E769B 101427-01 Rev . B 01/00 Version B - For Reduction G016.J ® LIMITED WARRANTY DAYTON ONE-YEAR LIMITED WARRANTY. Natural gas construction heater, Models covered in this manual are warranted by Dayton Electric Mfg.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Dayton 4E769B c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Dayton 4E769B - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Dayton 4E769B, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Dayton 4E769B va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Dayton 4E769B, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Dayton 4E769B.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Dayton 4E769B. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Dayton 4E769B ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.