Manuel d'utilisation / d'entretien du produit 3VG79B du fabricant Dayton
Aller à la page of 16
Operating Instructions & Parts Manual 3VG79B Dayton Portable For ced Air Heater Description Dayton Model 3VG79B is a 200,000 Btu/Hr heater . This heater uses only Kerosene or No.
Dayton Operating Instructions and Parts Manual 2 Dayton Portable For ced Air Heater ® 3VG79B Figure 2 - Model 3VG79B Product Identification Thermostat Knob General Safety Information Make certain you read and understand all warnings. Keep these instructions for reference.
Dayton Operating Instructions and Parts Manual 3 Model 3VG79B Version B - For Reduction G016.J ® Carbon monoxide poisoning may lead to death! Some people are mor e affected by carbon monoxide than others. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea.
Dayton Operating Instructions and Parts Manual 4 Dayton Portable For ced Air Heater ® 3VG79B Fuels Use only Kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
Dayton Operating Instructions and Parts Manual 5 Model 3VG79B Version B - For Reduction G016.J ® 4. Place handles on top of fuel tank flange. Insert scr ews through handles, fuel tank flange, and wheel support frame. Attach nut finger tight after inserting each screw .
Dayton Operating Instructions and Parts Manual 6 Dayton Portable For ced Air Heater ® 3VG79B 7. Place setscrew on flat of shaft. Tighten setscrew firmly (40-50 inch-pounds). 8. Replace fan guard and upper shell. AIR OUTPUT , AIR INT AKE, AND LINT FIL TERS 1.
Dayton Operating Instructions and Parts Manual 7 Model 3VG79B Version B - For Reduction G016.J ® Maintenance (Continued) Side Cover Bushing, Lower Fuel Line, and Fuel Filter Figure 10 - Fuel Filter Removal Fuel V alve Fitting 4. Disconnect red and white wir es fr om fuel valve (See Figure 11).
Dayton Operating Instructions and Parts Manual 8 Dayton Portable For ced Air Heater ® 3VG79B Maintenance (Continued) Figure 13 - Ignitor Replacement Combustion Chamber Photocell Bracket Ignitor Ignitor Screw Nozzle Adapter Bracket Nozzle Adapter Bracket Opening Ignitor Element Washer NOZZLE ASSEMBL Y 1.
Dayton Operating Instructions and Parts Manual 9 Model 3VG79B Version B - For Reduction G016.J ® Sandpaper Figure 18 - Sanding Rotor Maintenance (Continued) STORING, TRANSPORTING, OR SHIP- PING NOTE: If shipping, transport companies requir e fuel tanks to be empty .
Dayton Operating Instructions and Parts Manual 10 Dayton Portable For ced Air Heater ® 3VG79B For Replacement Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P .
Dayton Operating Instructions and Parts Manual 11 Model 3VG79B Version B - For Reduction G016.J ® Ref. Part 2E510D 2E511D No. Description Number Qty .
Dayton Operating Instructions and Parts Manual 12 Dayton Portable For ced Air Heater ® 3VG79B Figure 23 - Replacement Parts Illustration Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P .
Dayton Operating Instructions and Parts Manual 13 Model 3VG79B Version B - For Reduction G016.J ® Ref. Part No. Description Number Qty . Ref. Part No.
Dayton Operating Instructions and Parts Manual 14 Dayton Portable For ced Air Heater ® 3VG79B Replacement Parts List for Handle and Wheel Group Ref. Part No.
Dayton Operating Instructions and Parts Manual 15 Model 3VG79B Version B - For Reduction G016.J ® 1. No power to heater 2. Thermostat setting to low 3. Bad electrical connection between motor and ignition control assembly or ignition control assembly and power cor d 4.
Dayton Operating Instructions and Parts Manual 16 Dayton Portable For ced Air Heater ® 3VG79B Manufactured for Dayton Electric Mfg. Co. Niles, Illinois 60714 U.S.A. 107326-01 Rev . D 12/00 Version B - For Reduction G016.J ® NOT A UPC LIMITED WARRANTY DA YTON ONE-YEAR LIMITED WARRANTY .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Dayton 3VG79B c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Dayton 3VG79B - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Dayton 3VG79B, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Dayton 3VG79B va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Dayton 3VG79B, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Dayton 3VG79B.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Dayton 3VG79B. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Dayton 3VG79B ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.