Manuel d'utilisation / d'entretien du produit 3VG79 du fabricant Dayton
Aller à la page of 16
Operating Instructions & Parts Manual 3VG79 Dayton Portable For ced Air Heaters Description Dayton Model 3VG79 is a 200,000 Btu/Hr heater . This heater uses Kerosene or #1 fuel oil for combustion and electricity to run the motor .
Dayton Operating Instructions and Parts Manual 2 Dayton Portable Oil-Fir ed Heaters ® 3VG79 Lower Shell Hot Air Outlet Fan Guard Fuel T ank Flame-out Control Reset Button Side Cover Fuel Cap Figure 2.
Dayton Operating Instructions and Parts Manual 3 Model 3VG79 Version B - For Reduction G016.J ® General Safety Information Make certain you read and understand all warnings. Keep these instructions for refer ence. They are your guide to safe and proper operation of this heater .
Dayton Operating Instructions and Parts Manual 4 Dayton Portable Oil-Fir ed Heaters ® 3VG79 General Safety Information (Continued) Theory of Operation Fuels Use only kerosene or No. 1 fuel oil to avoid risk of fire or explosion. Never use gasoline, naphtha, paint thinners, alcohol, or other highly flammable fuels.
Dayton Operating Instructions and Parts Manual 5 Model 3VG79 Version B - For Reduction G016.J ® Front Handle Rear Handle Wheel Support Frame Hot Air Outlet Fuel T ank Flange Screw Air Inlet Assembly This model is furnished with wheels and handles. Wheels, handles, and the mounting hardwar e are found in the shipping carton.
Dayton Operating Instructions and Parts Manual 6 Dayton Portable Oil-Fir ed Heaters ® 3VG79 FAN IMPORT ANT : Remove fan from motor shaft before r emoving motor from heater . The weight of the motor resting on the fan could damage the fan pitch. 1. Remove upper shell (See Figure 6).
Dayton Operating Instructions and Parts Manual 7 Model 3VG79 Version B - For Reduction G016.J ® Figure 10 - Adjusting Pump Pr essure Pressure Gauge Side Cover Bushing, Lower Fuel Line, and Fuel Filter Figure 11 - Fuel Filter Removal Fuel V alve Fitting High V oltage.
Dayton Operating Instructions and Parts Manual 8 Dayton Portable Oil-Fir ed Heaters ® 3VG79 Air Line Hose Screw Combustion Chamber Burner Head Spark Plug Wire Spark Plug Fuel Line Hose NOZZLE 1. Remove upper shell (See page 6). 2. Remove fan (See page 6).
Dayton Operating Instructions and Parts Manual 9 Model 3VG79 Version B - For Reduction G016.J ® Sandpaper Gap Adjusting Screw Gap Adjusting Screw .003"/.004" Gap Measured With Feeler Gauge Rotor Blade 5. Remove pump plate. 6. Remove rotor , insert, and blades.
Dayton Operating Instructions and Parts Manual 10 Dayton Portable Oil-Fir ed Heaters ® 3VG79 For Replacement Parts, call 1-800-323-0620 24 hours a day - 365 days a year Please provide following infor.
Dayton Operating Instructions and Parts Manual 11 Model 3VG79 Version B - For Reduction G016.J ® Ref. Part 2E510D 2E511D No. Description Number Qty . Qty .
Dayton Operating Instructions and Parts Manual 12 Dayton Portable Oil-Fir ed Heaters ® 3VG79 Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts Operations P .
Dayton Operating Instructions and Parts Manual 13 Model 3VG79 Version B - For Reduction G016.J ® 3VG79 Replacement Parts List Ref. Part No. Description Number Qty .
Dayton Operating Instructions and Parts Manual 14 Dayton Portable Oil-Fir ed Heaters ® 3VG79 Replacement Parts List for Handle and Wheel Group Ref. Part No.
Dayton Operating Instructions and Parts Manual 15 Model 3VG79 Version B - For Reduction G016.J ® T roubleshooting Chart Possible Cause(s) Corrective Action Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur .
Dayton Operating Instructions and Parts Manual 16 Dayton Portable Oil-Fir ed Heaters ® 3VG79 Manufactured for Dayton Electric Mfg. Co. Niles, Illinois 60714 103536-01 Rev . B 3/97 Version B - For Reduction G016.J ® Limited Warranty Dayton One-Year Limited Warranty.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Dayton 3VG79 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Dayton 3VG79 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Dayton 3VG79, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Dayton 3VG79 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Dayton 3VG79, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Dayton 3VG79.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Dayton 3VG79. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Dayton 3VG79 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.