Manuel d'utilisation / d'entretien du produit 2E511D du fabricant Dayton
Aller à la page of 24
Operating Instructions & Parts Manual Dayton Portable Oil-Fir ed Heaters ® Form 5S1792 Please read and save these instructions. Read car efully before attempting to assemble, install, operate or maintain the pr oduct described. Protect yourself and others by observing all safety information.
Dayton Operating Instructions and Parts Manual 2 Dayton Portable Oil-Fir ed Heaters ® 101421 Amperage Model Electrical Input (during normal run) 2E510D 120 V olt/60 Hertz 2.0 2E511D 120 V olt/60 Hertz 2.0 3E218D 120 V olt/60 Hertz 4.5 3E219C 120 V olt/60 Hertz 4.
3 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® General Safety Information Make certain you read and understand all warnings. Keep these instructions for reference. They are your guide to safe and proper operation of this heater .
Dayton Operating Instructions and Parts Manual 4 Dayton Portable Oil-Fir ed Heaters ® 101421 General Safety Information (Continued) Figure 5 - Cr oss Section Operational View Clean Heated Air Out Air.
5 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® ASSEMBL Y (For Models 3E218D and 3E219C Only) These models are furnished with wheels and handles. Wheels, handles, and the mounting hardware are found in the shipping carton.
Dayton Operating Instructions and Parts Manual 6 Dayton Portable Oil-Fir ed Heaters ® 101421 Figure 8 - Flame-out Contr ol Reset Button, Models 3E218D and 3E219C Operation (Continued) 5. Plug extension cord into standard 120 volt/60 hertz, three-hole, grounded outlet.
7 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® Figure 12 - Fan Cr oss Section, Model 3E219C AIR OUTPUT , AIR INT AKE, AND LINT FIL TERS 1. Remove upper shell (see Figure 10). 2. Remove filter end cover screws using 5/16" nut-driver .
Dayton Operating Instructions and Parts Manual 8 Dayton Portable Oil-Fir ed Heaters ® 101421 Maintenance (Continued) Side Cover Upper Fuel Line Fuel Filter Figure 17 - Fuel Filter Removal, Models 2E510D and 2E511D Side Cover Upper Fuel Line Figure 18 - Fuel Filter Removal, Models 3E218D and 3E219C SP ARK PLUG (Models 2E510D and 2E511D) 1.
9 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® Spark Plug Wire Spark Plug Burner Head Figure 22 - Spark Plug Removal, Models 3E218D and 3E219C Maintenance (Continued) 5. Clean and regap spark plug elec- trodes to .
Dayton Operating Instructions and Parts Manual 10 Dayton Portable Oil-Fir ed Heaters ® 101421 Maintenance (Continued) NOZZLE (Models 3E218D and 3E219C) 1. Remove upper shell (see page 6). 2. Remove fan (see page 6). 3. Remove fuel and air line hoses from burner head.
11 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® NOTE : If rotor is still binding, proceed as follows. 13. Perform steps 1 through 6 (see page 10). 14. Place fine grade sandpaper (600 grit) on flat surface.
Dayton Operating Instructions and Parts Manual 12 Dayton Portable Oil-Fir ed Heaters ® 101421 For Replacement Parts, call 1-800-323-0620 Please provide following information: -Model number -Serial number (if any) -Part descriptions and number as shown in parts list Address parts correspondence to: Grainger Parts Operations P .
13 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® Replacement Parts List Models 2E510D, 2E511D, 3E218D and 3E219C Portable Oil-Fir ed Heaters 2E510D, 2E511D, 3E218D, and 3E219C Ref. Part 2E510D 2E511D No.
Dayton Operating Instructions and Parts Manual 14 Dayton Portable Oil-Fir ed Heaters ® 101421 Please provide following information: -Model number -Serial number (if any) -Part descriptions and number as shown in parts list Address parts correspondence to: Grainger Parts Operations P .
15 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® 2E510D and 2E511D (*) Standard hardware item, available locally .
Dayton Operating Instructions and Parts Manual 16 Dayton Portable Oil-Fir ed Heaters ® 101421 For Replacement Parts, call 1-800-323-0620 Please provide following information: -Model number -Serial number (if any) -Part descriptions and number as shown in parts list Address parts correspondence to: Grainger Parts Operations P .
17 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® 3E218D Replacement Parts List Model 3E218D Portable Oil-Fir ed Heater (*) Standard hardware item, available locally . ( ∆ ) Not shown. (†) Not available as an assembly , see pages 14 and 15.
Dayton Operating Instructions and Parts Manual 18 Dayton Portable Oil-Fir ed Heaters ® 101421 For Replacement Parts, call 1-800-323-0620 Please provide following information: -Model number -Serial number (if any) -Part descriptions and number as shown in parts list Address parts correspondence to: Grainger Parts Operations P .
19 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® 3E219C Replacement Parts List Model 3E219C Portable Oil-Fired Heater Ref. Part 3E219C No. Description Number Qty . Ref. Part 3E219C No. Description Number Qty .
Dayton Operating Instructions and Parts Manual 20 Dayton Portable Oil-Fir ed Heaters ® 101421 Replacement Parts List for Handle and Wheel Group Models 3E218D and 3E219C Figure 39 - Handle and Wheel Assembly 3 4 5 8 7 6 2 1 Ref. Part Number No. Description 3E218D 3E519C Qty .
21 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® Wiring Diagrams Figure 41 - Wiring Diagram for Models 3E218D and 3E219C White Black Blue Green Pow.
Dayton Operating Instructions and Parts Manual 22 Dayton Portable Oil-Fir ed Heaters ® 101421 T roubleshooting Chart Possible Cause(s) Corrective Action Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur .
23 Models 2E510D, 2E511D, 3E218D, and 3E219C Dayton Operating Instructions and Parts Manual 101421 ® __________________________________________________________________________________________________.
Dayton Operating Instructions and Parts Manual 2E510D, 2E511D, 3E218D, and 3E219C Manufactured for Dayton Electric Mfg. Co. Niles, Illinois 60714 101421-01 Rev . C 03/98 Version B - For Reduction G016.J ® Dayton Portable Oil-Fir ed Heaters LIMITED WARRANTY Dayton One-Year Limited Warranty.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Dayton 2E511D c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Dayton 2E511D - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Dayton 2E511D, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Dayton 2E511D va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Dayton 2E511D, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Dayton 2E511D.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Dayton 2E511D. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Dayton 2E511D ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.