Culligan ® Iron-Cleer ® Plus Automatic Water Filter Owners Guide.
Thank You And Welcome To Your New World Of Better Living With Culligan Water. This system and its installation must comply with state and local regulations.
Table of Contents iii S p e c i f i c a t i o n s ................................................1 I n t r o d u c t i o n ..................................................2 O p e r a t i n g C o n d i t i o n s .....................................
This page intentionally left blank. iv.
Specifications Culligan ® Iron Cleer ® Plus Filters 10” Iron Cleer 12” Iron Cleer Control Valve 1” 5-cycle reinforced thermoplastic 1” 5-cycle reinforced thermoplastic Timer Electro-mechanical Electro-mechanical Overall Conditioner Height 67” 65” Media Tank Dimensions (D x H) 2 ea.
Introduction Operation Step 1. Aeration Operation Service Cycle In the service cycle, raw water enters the inlet port of the aeration tank and is directed through the inlet diffuser. The oxidation process begins when the water passes through the inlet diffuser and cascades through a head of air.
Shuttle Valve Operation In the service position, water pressure holds the shuttle valve piston in the closed position, trapping the airhead in the aeration tank and closes the air recharge inlet port and drain port. During air recharge cycle, air pressure is greater than the water pressure and forces the shuttle valve piston in the open piston.
The concentration limits listed below reflect the maximum individual limit that each contaminant was tested for separately without any interference of other contaminants in the influent water.
Fam il iar iza tio n Power Loss The AccuSoft ® circuit board is equipped with a Hi-Cap Capacitor and EEPROM memory chip. The capacitor is capable of maintaining the time, for at least two days, in the event of a power outage. The EEPROM ensures that the individual programming parameters of your filter are not lost.
Famil iariz ation (cont .) Modes of Operation Manual Regeneration Pressing and holding the regen button for 3 seconds will initiate an immediate regeneration. The beeper is to give one beep at the start of manual regeneration (when the motor starts to turn).
7 The Culligan ® AccuSoft ® Plus circuit board controls all of the filter functions. These settings are programmed at the time of installation. The following is a list of all the microprocessor functions, in the event that any of the settings need to be adjusted.
8 • Time of Regeneration - This setting is used to program the time at which a regeneration is to occur in the delay mode, or in immediate mode with time clock backup on.
9 • Filter Media Life (Change Media) - This setting is used in Filter Mode ONLY with flow meter attached. It enables or disables an alarm code (“CHANGE MEDIA”) that indicates the end of life for the filter media.
10 The statistical functions are reached by pressing the “Information” key. Repetitive presses of the “Information” key will cycle through the standard statistics mode until cycled back to time of day display.
11 When and How to Bypass Your Water Conditioner Normally, all water except outside lines passes through the water conditioner. There are times when the water conditioner should be bypassed, using the Cul-Flo-Valv ® Bypass, or a 3-way bypass valve. You should bypass: 1.
12 Aeration T ank – Bypass V alve Operation Normal Operation Bypass Operation “T reated” Water Exits Supply W ater Enters Supply W ater Exits Supply W ater Enters Shut-Off Mode No W ater Exits S.
13 Things to Check Before You Call for Service If you unexpectedly experience problem water, make these simple checks before calling your Culligan dealer.
Rec om men ded Pre ve nta tiv e Mai nt ena nce The Culligan Iron Cleer water filter has been designed to provide a good, consistent service life. Because of the nature of problem water, we recommend that the local Culligan dealer provide regular maintenance/service contracts for the proper operation of your systems.
15 Troubleshooting Guide Complaint Problem Cause Solution Iron bleed- through or staining. A. Inadequate backwash of filter 1. Plugged drain line flow control 1. Call your Culligan dealer for service. 2. Insufficient water supply from well. 2. Check for minimum specified flow and pressure requirements of filter system.
16 Complaint Problem Cause Solution Water leaking from relief valve. A. Dirt lodged under seat of valve. 1. Pressure has exceeded rating on relief valve and caused valve to open 1. Call your Culligan dealer for service. B. Faulty or defective relief valve 1.
17 Complaint Problem Cause Solution Water is running to drain continuously. A. Control valve is stuck in regeneration cycle. 1. Electrical service to control(s) has been interrupted. 1. Assure continuous electrical service is available. (check plug, breaker, fuse, etc.
Performance Data Sheet Culligan ® 10” and 12” Iron-Cleer ® Water Filters Important Notice — Read this data sheet and compare the capabilities of the unit to your actual water treatment needs. Culligan recommends that you have your water supply tested to determine these needs before purchasing a water treatment unit.
19 Records and Data Important Data on Your Water Filter It is advisable to have the salesperson or installer fill in the information below for your future reference. If this has not been done, please ask for it, as it is necessary if you contact your dealer.
Culligan Limited Warranty Culligan ® Iron-Cleer ® Automatic Water Filters You have just purchased one of the finest water conditioners made. As an expression of our confidence in Culligan Internatio.
21 With Culligan You Get More Than A Quality Product You Get Your Water Expert, The Culligan Man ® We’re here to provide you with fast, dependable service, making sure any problems you have are taken care of. The Culligan Man has been around for over seventy years, delivering dependable service all along.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Culligan Iron-Cleer Plus c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Culligan Iron-Cleer Plus - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Culligan Iron-Cleer Plus, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Culligan Iron-Cleer Plus va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Culligan Iron-Cleer Plus, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Culligan Iron-Cleer Plus.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Culligan Iron-Cleer Plus. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Culligan Iron-Cleer Plus ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.