Manuel d'utilisation / d'entretien du produit 32-475ECS du fabricant Crown Boiler
Aller à la page of 16
D e s i g n e D t o L e a D T el: (215) 535-8900 • Fax: (215) 535-9736 • www .crownboiler .com Manufacturer of Hydronic Heating Products P .O. Box 14818 3633 I.
.
I Pr oduct Description This supplement covers information not included in the standard Series 32 installation manual that is unique to the following models: 32-380WNLECS, 32-475WNLECS 32-380WNTECS, 32-475WNTECS 32-380SNLECS, 32-475SNLECS Follow the Series 32 installation instructions except where noted in this supplement.
VII V enting Refer to installation manual. V ent sizing for the 32-380ECS should always be done in accordance with the National Fuel Gas Code. A vent damper can be installed on any 32-380ECS or 32-475ECS equipped with a 24 volt control system except for those with tankless heaters.
W ARNING All wiring and grounding must be done in accordance with the authority having jurisdiction or , in the absence of such CAUTION Make sure that damper and BVS harnesses are secured so that they do not come in contact with draft hood or steam piping.
“BURNER” “BURNER” TH TR + ROBERTSHAW 7000DERHC GAS V AL VE VENT DAMPE R (NOTE 2) NOTE 2 LESS VENT DAMPER 2. ON BOILERS LESS VENT DAMPER, DAMPER HARNESS NOT USED. RED AND BLUE LEADS ARE JUMPED TOGETHER USING RED JUMPER WIRE. RD RD RD ALARM ALARM 2 (NOTE 2) 2.
Sequence of Operation - Steam Boiler 1) When the boiler is ener gized, 24 volts is immediately applied to terminals “1” (blue) and “4” (yellow) on the vent damp - er . Assuming that there is no call for heat, and that the damper switch is in the “automatic” position, the damper will close.
2 HIGH LIMIT LOW LIMIT HONEYWELL L8124E TH TR + ROBERTSHAW 7000DERHC GAS VAL VE PILOT VAL VE MAIN VAL VE RD RD RD/YE RD RD/YE ALARM ALARM Figure C: W ater Boiler Wiring (W ith T ankless Heater) Figure.
equipped with a reset button which must be pressed to restore normal burner operation. An open blocked vent switch is indicative of a problem with the vent system. If the blocked vent switch opens, the cause of the venting problem must be found and corrected by a qualied gas service technician before the blocked vent switch is reset.
Figure F: W ater Boiler Contr ol Installation (Less T ankless Heater V ersion Shown) Figure E: Blocked V ent Switch Installation 8.
6) Once the ignition module detects the presence of a pilot ame, voltage is applied across the main valve (terminals “MV” and “MV/PV”), opening the valve and establishing main ame.
380 475 380 475 I A PART # (STANDARD) 310000 310001 310002 3110053 3110063 310405 310406 311026 311020 311010 310400 311027 311028 311031 1 EA. 1 EA. BOILER MODEL 32-380ECS 1 1 3 1 1 1 1 1 1 1 1 31103.
BASE SIDE CAR TON - See Installation Manual JACKET SIDE P ANEL CAR TON- See Installation Manual W A TER AND STEAM BOILER CAR TONS - As shown in Installation Manual except that Rating Plate is factory applied to RH Side Jacket Panel.
12 STEAM PROBE CONTROL SUB ASSY 3513210 1 LWCO, CG400 WITH "P" PROBE 400824 1 BLOCKED VENT SWITCH ASSY 960128 1 GLASS SET (20-104-10, 8" CTR TO CTR) 950080 1 L404F PRESSURE LIMIT 350380.
.
PN 980895 05/10 T el: (215) 535-8900 • Fax: (215) 535-9736 • www .crownboiler .com Manufacturer of Hydronic Heating Products P .O. Box 14818 3633 I.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Crown Boiler 32-475ECS c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Crown Boiler 32-475ECS - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Crown Boiler 32-475ECS, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Crown Boiler 32-475ECS va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Crown Boiler 32-475ECS, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Crown Boiler 32-475ECS.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Crown Boiler 32-475ECS. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Crown Boiler 32-475ECS ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.