Manuel d'utilisation / d'entretien du produit CP2 du fabricant Crestron electronic
Aller à la page of 40
.
This document was prepared and written by th e Technical Docum entation department at: Crestron Electronics, Inc. 15 Volvo D rive Rockleigh, NJ 076 47 1-888-CRESTRON.
Crestron CP2/CP2E 2-Series Integrated Control Processor Contents 2-Series Integrated Control Processor: CP2/CP2E 1 Introduc tion ................................................................................................................... ......
.
Crestron CP2/CP2E 2-Series Integrated Control Processor 2-Series Integrated Control Processor: CP2/CP2E Introduction Features and Functions Crestron’s CP2 and CP2E 2-Series Integrated Con trol Proce.
2-Series Integrated Control Processor Crestron CP2/CP2E bit Motorola ColdFire processor. The 2-Series operating system is vastly upgraded from Crest ron’s X-gene ration pro ducts, yet compatible with existing Crestron software and programm ing.
Crestron CP2/CP2E 2-Series Integrated Control Processor Physical Description The CP2/CP2E integrated control systems are housed in black enclos ures with labeling on t he front an d rear panels . The front panels of b oth units i nclude standar d LEDs and two reset buttons.
2-Series Integrated Control Processor Crestron CP2/CP2E Controls and Indicators The CP2/CP2E front panel indicators a nd controls a re described bel ow. PWR (Power) This LED illuminates when the unit is co nnected to and receives 24VDC power from an AC power pack or the C resnet NET connector.
Crestron CP2/CP2E 2-Series Integrated Control Processor NOTE: The orientation of this connector is “upside down” co mpared to other Crestron networ k devices (e.g., CNX-BI PAD8, CNX-RMCLV). Be sure the mating Cresnet cable connector is pr operly aligned before attempting to insert it, to avoid damage to the CP2/C P2E unit .
2-Series Integrated Control Processor Crestron CP2/CP2E COM Pinout to RS-485 Bus COM ( DB9) CO NNECT O R RS-485 BUS T ie Pins 1 & 9 - T ie Pins 4 & 6 + Pin 5 G INFRARED – SERIAL OU TPUT A B C D E F G H S G S G S G S G INFRA RED - SERIAL OUTPUT S G S G S G S G These connectors provi de eight serial outp uts for IR or serial int erface.
Crestron CP2/CP2E 2-Series Integrated Control Processor 24VDC, 2.0A (Power Supply) 24VDC 2.0A This male connector can be used to supply 24 VDC power to the CP2/CP2E from an AC power pac k purchased se parately. (Re fer to O ptional Powe r Supply on page 1 3).
2-Series Integrated Control Processor Crestron CP2/CP2E series control engine. Non-vo latile memory c ontains information that is retained after loss of electrical power. Volatile memory is lost after a power failure. Refer to the lists below for a breakdown of memory usage for program-related information stored in the unit.
Crestron CP2/CP2E 2-Series Integrated Control Processor DRAM DRAM is use d by the ope rating system for dynam ic storage of variables, si gnals and other const ructs use d at runti me. The actua l amount of DR AM used at a ny given time depends on the particular program that is running , i.
2-Series Integrated Control Processor Crestron CP2/CP2E Ear Attachment for Rack Mounting (CP2E shown in illustration) 1. Using a Phillips screwdriver, remove and retain the three side screws closest to the fr ont panel.
Crestron CP2/CP2E 2-Series Integrated Control Processor 5. Secure the wires connected to the te rm inal block with a ti e wrap around the bussing stri p to provi de strain reli ef. Network Wiring NOTE: When making wire connections, refer to the latest revision of the Cresnet Network Inte rconnect Dra wing (Doc.
2-Series Integrated Control Processor Crestron CP2/CP2E Wire Gauge Values RESISTANCE (R) WIRE GAUGE 4 16 6 18 10 20 15 22 13 Doubled CAT 5 8.7 Tripled CAT5 NOTE: When dais y-chaining Cresnet unit s, stri p the ends of the wires carefully to avoid nicking the condu ctors.
Crestron CP2/CP2E 2-Series Integrated Control Processor Optional Power Supply The units ca n be powe red through t he NET netw ork conne ctor, or by an optional AC power p ack (pur chased separa tely).
2-Series Integrated Control Processor Crestron CP2/CP2E Slot 1: C2Net-Device The C2Net-De vice slot ena bles the CP2 an d CP2E to c ontrol up t o 252 Cr esnet devices. Each Cresnet de vice is assigned a unique identifier called a Net ID, which is a hexadecim al value rangi ng from 03 to FE.
Crestron CP2/CP2E 2-Series Integrated Control Processor Slot 3: C2I-IO8 The CP2 and C P2E pro vide eight I/O ports c alled Ve rsiports, eac h of whi ch can function as a digital i nput, a di gital out put, or an a nalog in put. Each Versi port has a correspondin g pullup resistor.
2-Series Integrated Control Processor Crestron CP2/CP2E Driving the correspondi ng <pu-disabl e> signal hi gh can modi fy this beha vior. This i s not recommended, though , since it will cause the output pin to float when < o > goes low. Example 1 (rec ommended): The < pu-disable1 > signal is driven low or left undefined.
Crestron CP2/CP2E 2-Series Integrated Control Processor A voltage source is pl aced on Ve rsiport 1 a nd < MinChange1 > is set t o 10 via an Analog Initialize symbol. The value of < i1 > will not be propag ated until it changes by at least 10.
2-Series Integrated Control Processor Crestron CP2/CP2E 3. When all t he IP IDs and ass ociated IP ad dresses have been adde d to the IP Table, click Send IP Table to Contr ol System .
Crestron CP2/CP2E 2-Series Integrated Control Processor If the program contains S IMPL+ or User modules , the conversion might generate error messages. This is because m odules and programs often c ontain symbols with “ambiguous” s ignals. F or exam pl e, the inputs of the Serial to Analog sym bol can be defined as eith er analog or serial.
2-Series Integrated Control Processor Crestron CP2/CP2E Module Header Information After you convert each module in a prog ram, you can convert the program as described pre viously: dra g the CP2 or CP2E ont o the exis ting cont rol syst em in System Views and click Yes to confirm the re placement.
Crestron CP2/CP2E 2-Series Integrated Control Processor • Hardware ha ndshaking (R TS/CTS) e nabled. • Software ha ndshaki ng (XON/ XOFF) not e nabled. “Port Settings” dialog box: Default PC se ttings for RS-232 co mmunication with the CP2/CP2E.
2-Series Integrated Control Processor Crestron CP2/CP2E use a CAT5 cr ossover cabl e to connect th e two LAN ports directly, without using a hub. Once the cable connections are made, ope n the Crest ron Viewpo rt and clic k Setup | Communication Settings on the m enu to di splay the “Po rt Settings” di alog bo x.
Crestron CP2/CP2E 2-Series Integrated Control Processor some ma y be internal (e. g., for a m odem). Cons ult the m anufacture r’s documentation for fur ther information about th e COM ports on your PC. 3. Check the ERR LED indicat or on the f ront panel of the CP 2/CP2E.
2-Series Integrated Control Processor Crestron CP2/CP2E Compiling and Uploading a Program to the Control System After you have completed your SI MPL Windows program you must compile and upload the program to the control system.
Crestron CP2/CP2E 2-Series Integrated Control Processor Another way to verify t hat the program has been tra nsferred successfully is to select Report Program Information on the View port Functions menu. Prog ram information is also disp layed in the View port console whenever power is removed and re-applied to the CP2/CP2E.
2-Series Integrated Control Processor Crestron CP2/CP2E Uploading Touchpanel Pr ojects via the CP2/CP2E You can use a connection t o the CP2 or CP2E to upload Visi onTools Pro- e projects to any Cresnet touchpa nel. Com piled projects f or TPS pane ls are contai ned in V TZ files; project s for all othe r touchpa nels are cont ained in HEX files.
Crestron CP2/CP2E 2-Series Integrated Control Processor 3. After the transfer is complete, the CP2/CP2E will automatically reboot. To confirm the tr ansfer , click Diagnostics | Check Ops Version . The Viewport c onsole sho uld disp lay the new .c uz versi on num ber.
2-Series Integrated Control Processor Crestron CP2/CP2E Troubleshooting The table belo w and on t he next page provides cor rective action fo r possible trouble situations. If further assistance is requi red, please contact a Crestron cust omer service representative.
Crestron CP2/CP2E 2-Series Integrated Control Processor Battery Replacement A Lithium battery is used to power the system clock within the CP2/CP2E. Under normal conditions, it will last for approximately 10 years. In the event that the clock fails, only an authorized technician sh ould replace it.
2-Series Integrated Control Processor Crestron CP2/CP2E Passthrough Mode Dialog Box The PC will now be communicating directly with th e device. To exit Passthr ough mode, simply cl ick Functions | Exit Passthr ough Mode . A system reboot will also exit Passthrough mode.
Crestron CP2/CP2E 2-Series Integrated Control Processor Further Inquiries If after reviewing this Operations Guide, you cannot locate specific information or have questions , please take a dvantage of.
2-Series Integrated Control Processor Crestron CP2/CP2E Software License Agreement This License Agreement (“Agree ment”) is a legal contract betw een you (either an individual or a single business entit y) and Crestron Electronics, Inc.
Crestron CP2/CP2E 2-Series Integrated Control Processor If You are a business or organization, You agree that upon request from Crestron or its authorized agent, You will within thirty (30) days fully.
2-Series Integrated Control Processor Crestron CP2/CP2E Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchan dise may be retur ned for cr edit, exchan ge, or service without prior authorization from CR ESTRON.
Crestron CP2/CP2E 2-Series Integrated Control Processor This page intentionally left blank . Operations Guide - DOC. 5980 2-Series Integrated Control Processo r: CP2/CP2E • 35.
Crestron Electronics, Inc. Operations Guide – DOC. 5980 15 Volvo Drive Rockleigh, NJ 07647 02.02 Tel: 888.CRESTRON Fax: 201.767.7576 Specifications subject to www.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Crestron electronic CP2 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Crestron electronic CP2 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Crestron electronic CP2, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Crestron electronic CP2 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Crestron electronic CP2, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Crestron electronic CP2.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Crestron electronic CP2. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Crestron electronic CP2 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.